{"title":"General Cable EmPowr® 15 kV Longitudinally Applied Corrugated Tape LLDPE Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation","description":"","products":[{"product_id":"empowr-15-kv-longitudinally-applied-corrugated-tape-lldpe-jacket-link-and-shielded-power-cable-al-conductor-trxlpe-insulation","title":"General Cable EmPowr® 15 kV Longitudinally Applied Corrugated Tape LLDPE Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"13\" style=\"text-align: center;\"\u003elongitudinally applied corrugated tape shielded power cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\"\u003ecompressed\u003cbr\u003e conductor\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003ediameter (1)\u003cbr\u003e inches\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003enominal\u003cbr\u003e jacket\u003cbr\u003e thkn.\u003cbr\u003e inches\u003cbr\u003e (1)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eapprox. weight (1)\u003cbr\u003e lb\/1000 ft\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eampacity (2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd rowspan=\"2\"\u003eal\u003cbr\u003e awg or\u003cbr\u003e kcmil\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eno.\u003cbr\u003e of\u003cbr\u003e wires\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003einsulation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003elact shield\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003elldpe\u003cbr\u003e jacket\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eal\u003cbr\u003e cond.\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003ecu\u003cbr\u003e shield\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003etotal\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003edirect\u003cbr\u003e buried\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003ein\u003cbr\u003e duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003emin.\u003c\/td\u003e\n\u003ctd\u003emax.\u003c\/td\u003e\n\u003ctd\u003ethkn.\u003c\/td\u003e\n\u003ctd\u003eo.d.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"13\" style=\"text-align: center;\"\u003e175 mils nominal trxpe insulation – 15 kv 100% insulation level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-250mcm-15-kv-longitudinally-applied-corrugated-tape-1-264-lldpe-jacket-link-and-shie\"\u003e250\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e0.920\u003c\/td\u003e\n\u003ctd\u003e1.005\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.104\u003c\/td\u003e\n\u003ctd\u003e1.264\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003ctd\u003e814\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-250mcm-15-kv-longitudinally-applied-corrugated-tape-1-270-lldpe-jacket-link-and-shie\"\u003e250\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e0.920\u003c\/td\u003e\n\u003ctd\u003e1.005\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.110\u003c\/td\u003e\n\u003ctd\u003e1.270\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003ctd\u003e848\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-350mcm-15-kv-longitudinally-applied-corrugated-tape-1-367-lldpe-jacket-link-and-shie\"\u003e350\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.015\u003c\/td\u003e\n\u003ctd\u003e1.100\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.207\u003c\/td\u003e\n\u003ctd\u003e1.367\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003ctd\u003e157\u003c\/td\u003e\n\u003ctd\u003e984\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-350mcm-15-kv-longitudinally-applied-corrugated-tape-1-373-lldpe-jacket-link-and-shie\"\u003e350\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.015\u003c\/td\u003e\n\u003ctd\u003e1.100\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.213\u003c\/td\u003e\n\u003ctd\u003e1.373\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003ctd\u003e1020\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-500mcm-15-kv-longitudinally-applied-corrugated-tape-1-495-lldpe-jacket-link-and-shie\"\u003e500\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.150\u003c\/td\u003e\n\u003ctd\u003e1.235\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.335\u003c\/td\u003e\n\u003ctd\u003e1.495\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003ctd\u003e157\u003c\/td\u003e\n\u003ctd\u003e1190\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-500mcm-15-kv-longitudinally-applied-corrugated-tape-1-515-lldpe-jacket-link-and-shie\"\u003e500\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.150\u003c\/td\u003e\n\u003ctd\u003e1.235\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.355\u003c\/td\u003e\n\u003ctd\u003e1.495\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e1263\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-750mcm-15-kv-longitudinally-applied-corrugated-tape-1-696-lldpe-jacket-link-and-shie\"\u003e750\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e1.340\u003c\/td\u003e\n\u003ctd\u003e1.425\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.536\u003c\/td\u003e\n\u003ctd\u003e1.696\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e703\u003c\/td\u003e\n\u003ctd\u003e199\u003c\/td\u003e\n\u003ctd\u003e1574\u003c\/td\u003e\n\u003ctd\u003e665\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-750mcm-15-kv-longitudinally-applied-corrugated-tape-1-702-lldpe-jacket-link-and-shie\"\u003e750\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e1.340\u003c\/td\u003e\n\u003ctd\u003e1.425\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.542\u003c\/td\u003e\n\u003ctd\u003e1.702\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e703\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003ctd\u003e1620\u003c\/td\u003e\n\u003ctd\u003e665\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-1000mcm-15-kv-longitudinally-applied-corrugated-tape-1-905-lldpe-jacket-link-and-shi\"\u003e1000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e1.485\u003c\/td\u003e\n\u003ctd\u003e1.575\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.685\u003c\/td\u003e\n\u003ctd\u003e1.905\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003ctd\u003e208\u003c\/td\u003e\n\u003ctd\u003e1996\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-175miles-1000mcm-15-kv-longitudinally-applied-corrugated-tape-1-911-lldpe-jacket-link-and-shi\"\u003e1000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e1.485\u003c\/td\u003e\n\u003ctd\u003e1.575\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.691\u003c\/td\u003e\n\u003ctd\u003e1.911\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003ctd\u003e2050\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"13\" style=\"text-align: center;\"\u003e220 mils nominal trxpe insulation – 15 kv 133% insulation level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-250mcm-15-kv-longitudinally-applied-corrugated-tape-1-354-lldpe-jacket-link-and-shie\"\u003e250\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.010\u003c\/td\u003e\n\u003ctd\u003e1.100\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.194\u003c\/td\u003e\n\u003ctd\u003e1.354\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e899\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-250mcm-15-kv-longitudinally-applied-corrugated-tape-1-360-lldpe-jacket-link-and-shie\"\u003e250\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.010\u003c\/td\u003e\n\u003ctd\u003e1.100\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.200\u003c\/td\u003e\n\u003ctd\u003e1.360\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003ctd\u003e950\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-350mcm-15-kv-longitudinally-applied-corrugated-tape-1-457-lldpe-jacket-link-and-shie\"\u003e350\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.105\u003c\/td\u003e\n\u003ctd\u003e1.190\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.297\u003c\/td\u003e\n\u003ctd\u003e1.457\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003ctd\u003e157\u003c\/td\u003e\n\u003ctd\u003e1068\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-350mcm-15-kv-longitudinally-applied-corrugated-tape-1-463-lldpe-jacket-link-and-shie\"\u003e350\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.105\u003c\/td\u003e\n\u003ctd\u003e1.190\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.303\u003c\/td\u003e\n\u003ctd\u003e1.463\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003ctd\u003e1103\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-500mcm-15-kv-longitudinally-applied-corrugated-tape-1-599-lldpe-jacket-link-and-shie\"\u003e500\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.240\u003c\/td\u003e\n\u003ctd\u003e1.330\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.439\u003c\/td\u003e\n\u003ctd\u003e1.599\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003ctd\u003e1317\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-500mcm-15-kv-longitudinally-applied-corrugated-tape-1-605-lldpe-jacket-link-and-shie\"\u003e500\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1.240\u003c\/td\u003e\n\u003ctd\u003e1.330\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.445\u003c\/td\u003e\n\u003ctd\u003e1.605\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003ctd\u003e1365\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-750mcm-15-kv-longitudinally-applied-corrugated-tape-1-846-lldpe-jacket-link-and-shie\"\u003e750\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e1.430\u003c\/td\u003e\n\u003ctd\u003e1.520\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.626\u003c\/td\u003e\n\u003ctd\u003e1.846\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003ctd\u003e703\u003c\/td\u003e\n\u003ctd\u003e203\u003c\/td\u003e\n\u003ctd\u003e1778\u003c\/td\u003e\n\u003ctd\u003e665\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-750mcm-15-kv-longitudinally-applied-corrugated-tape-1-852-lldpe-jacket-link-and-shie\"\u003e750\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e1.430\u003c\/td\u003e\n\u003ctd\u003e1.520\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.632\u003c\/td\u003e\n\u003ctd\u003e1.852\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003ctd\u003e703\u003c\/td\u003e\n\u003ctd\u003e254\u003c\/td\u003e\n\u003ctd\u003e1830\u003c\/td\u003e\n\u003ctd\u003e665\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-1000mcm-15-kv-longitudinally-applied-corrugated-tape-1-995-lldpe-jacket-link-and-shi\"\u003e1000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e1.575\u003c\/td\u003e\n\u003ctd\u003e1.670\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003ctd\u003e1.775\u003c\/td\u003e\n\u003ctd\u003e1.995\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003ctd\u003e222\u003c\/td\u003e\n\u003ctd\u003e2124\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/electronic-utility\/empowr-220miles-1000mcm-15-kv-longitudinally-applied-corrugated-tape-2-001-lldpe-jacket-link-and-shi\"\u003e1000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e1.575\u003c\/td\u003e\n\u003ctd\u003e1.670\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003ctd\u003e1.781\u003c\/td\u003e\n\u003ctd\u003e2.001\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003ctd\u003e277\u003c\/td\u003e\n\u003ctd\u003e2181\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129858572351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_1fa85cc1-79e8-410b-b810-86ac408abd93.jpg?v=1571726261"},{"product_id":"empowr-175miles-1000mcm-15-kv-longitudinally-applied-corrugated-tape-1-905-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 1.905 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 1.905 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 1.905 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 1000MCM 15 kV 1.905 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.575\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.905\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1996\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129860243519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_2a34a513-2afa-4801-9f10-819c111a1446.jpg?v=1571726261"},{"product_id":"empowr-175miles-1000mcm-15-kv-longitudinally-applied-corrugated-tape-1-911-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 1.911 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 1.911 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 1.911 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 1000MCM 15 kV 1.911 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.575\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.691\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.911\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e2050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129860276287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_d78970ee-1512-4cc4-a307-18f63be2fe2d.jpg?v=1571726261"},{"product_id":"empowr-175miles-250mcm-15-kv-longitudinally-applied-corrugated-tape-1-264-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.264 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.264 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.264 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 250MCM 15 kV 1.264 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e0.920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.264\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e814\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129860309055,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_adc1641b-df59-4ca1-bc02-dfde2928067c.jpg?v=1571726261"},{"product_id":"empowr-175miles-250mcm-15-kv-longitudinally-applied-corrugated-tape-1-270-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.270 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.270 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.270 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 250MCM 15 kV 1.270 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e0.920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e848\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129861619775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_6b7c0211-02c9-405b-bbef-53f675afd92e.jpg?v=1571726262"},{"product_id":"empowr-175miles-350mcm-15-kv-longitudinally-applied-corrugated-tape-1-367-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.367 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.367 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.367 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 350MCM 15 kV 1.367 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.367\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e157\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e984\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129861652543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_e0689eff-298e-4aaa-85d0-90e7dc7c7a4e.jpg?v=1571726262"},{"product_id":"empowr-175miles-350mcm-15-kv-longitudinally-applied-corrugated-tape-1-373-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.373 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.373 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.373 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 350MCM 15 kV 1.373 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129861685311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_082fc3d7-3c38-47bf-9b0f-48a7d6267c96.jpg?v=1571726262"},{"product_id":"empowr-175miles-500mcm-15-kv-longitudinally-applied-corrugated-tape-1-495-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.495 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.495 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.495 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 500MCM 15 kV 1.495 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e157\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129861718079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_9bbc29eb-b7c4-4f92-a4c4-bc825744d52c.jpg?v=1571726262"},{"product_id":"empowr-175miles-500mcm-15-kv-longitudinally-applied-corrugated-tape-1-515-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.515 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.515 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.515 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 500MCM 15 kV 1.515 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1263\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129862275135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_d245adfb-f846-4a5d-836d-7279efd8b6e0.jpg?v=1571726262"},{"product_id":"empowr-175miles-750mcm-15-kv-longitudinally-applied-corrugated-tape-1-696-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.696 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.696 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.696 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 750MCM 15 kV 1.696 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.536\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.696\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1574\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129862438975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_eefb0a9f-4f0a-41ec-a51e-dfc8029a053d.jpg?v=1571726262"},{"product_id":"empowr-175miles-750mcm-15-kv-longitudinally-applied-corrugated-tape-1-702-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 175Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.702 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 175Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.702 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 175Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.702 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 175Miles 750MCM 1.702 LLDPE Jacket,15 kV EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.542\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129862471743,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_b56d003f-f4af-43f4-9468-f60749fec543.jpg?v=1571726262"},{"product_id":"empowr-220miles-1000mcm-15-kv-longitudinally-applied-corrugated-tape-1-995-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 1.995 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 1.995 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 1.995 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 1000MCM 15 kV 1.995 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Applied Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.575\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.995\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e222\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e2124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129869647935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_522845c6-01b1-4ba6-82f1-f2a9b024b28a.jpg?v=1571726277"},{"product_id":"empowr-220miles-1000mcm-15-kv-longitudinally-applied-corrugated-tape-2-001-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 2.001 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 2.001 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 1000MCM 15 kV Longitudinally Applied Corrugated Tape 2.001 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 1000MCM 15 kV 2.001 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Applied Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.575\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.781\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e2.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e2181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129869680703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_850cbf57-8953-414a-9b28-6ee7dfc213d0.jpg?v=1571726278"},{"product_id":"empowr-220miles-250mcm-15-kv-longitudinally-applied-corrugated-tape-1-354-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.354 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.354 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.354 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 250MCM 15 kV 1.354 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.194\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.354\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e899\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129870041151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_0f6f2be0-cba8-4655-b15e-ecd03ca7d99d.jpg?v=1571726278"},{"product_id":"empowr-220miles-250mcm-15-kv-longitudinally-applied-corrugated-tape-1-360-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.360 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.360 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 250MCM 15 kV Longitudinally Applied Corrugated Tape 1.360 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 250MCM 15 kV 1.360 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129870073919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_a5c177d1-e05b-4f1a-8ae9-6f3f3bd4ab3e.jpg?v=1571726278"},{"product_id":"empowr-220miles-350mcm-15-kv-longitudinally-applied-corrugated-tape-1-457-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.457 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.457 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.457 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 350MCM 15 kV 1.457 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.297\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.457\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e157\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129870106687,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_d837296e-1328-433c-87c0-0e09ab20004a.jpg?v=1571726278"},{"product_id":"empowr-220miles-350mcm-15-kv-longitudinally-applied-corrugated-tape-1-463-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.463 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.463 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 350MCM 15 kV Longitudinally Applied Corrugated Tape 1.463 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 350MCM 15 kV 1.463 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Applied Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129870139455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_baefbc85-18fb-444e-8dc5-0d4f846d049a.jpg?v=1571726278"},{"product_id":"empowr-220miles-500mcm-15-kv-longitudinally-applied-corrugated-tape-1-599-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.599 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.599 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.599 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 500MCM 15 kV 1.599 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Applied Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.439\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129870172223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_67f30b6f-808b-4356-846e-d2d36fbebf98.jpg?v=1571726278"},{"product_id":"empowr-220miles-500mcm-15-kv-longitudinally-applied-corrugated-tape-1-605-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.605 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.605 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 500MCM 15 kV Longitudinally Applied Corrugated Tape 1.605 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 500MCM 15 kV 1.605 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Applied Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129870204991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_611a87a1-9730-424a-b69c-92c62098c9c1.jpg?v=1571726278"},{"product_id":"empowr-220miles-750mcm-15-kv-longitudinally-applied-corrugated-tape-1-846-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.846 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.846 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.846 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 750MCM 15 kV 1.846 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Applied Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129870336063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_30ebab49-9953-44af-95ac-5e491885f145.jpg?v=1571726278"},{"product_id":"empowr-220miles-750mcm-15-kv-longitudinally-applied-corrugated-tape-1-852-lldpe-jacket-link-and-shielded-power-cable-al-cond-trxlpe-ins","title":"General Cable EmPowr® 220Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.852 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.","description":"EmPowr 220Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.852 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\u003cmeta name=\"Description\" content=\"EmPowr 220Miles 750MCM 15 kV Longitudinally Applied Corrugated Tape 1.852 LLDPE Jacket Link and Shielded Power Cable Al Cond. TRXLPE Ins.\"\u003e\u003cmeta name=\"Keywords\" content=\"EmPowr 220Miles 750MCM 15 kV 1.852 LLDPE Jacket,EmPowr 15 kV Cable, Longitudinally Applied Corrugated Tape Cable, LLDPE Jacket Link Cable, Shielded Power Cable, Al Conductor TRXLPE Insulation Cable, TRXLPE Insulation Cable, EmPowr 15 kV Longitudinally Applied Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Crosslinked Polyethylene (TRXLPE) insulated shielded power cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compressed concentric lay stranded 1350 aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLongitudinally Applied Corrugated Tape\u003c\/strong\u003e: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black, non-conducting, sunlight-resistant Linear Low-Density Polyethylene (LLDPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003cbr\u003e • Lead-free environmentally friendly cable\u003cbr\u003e • Even distribution of fault current and better heat dissipation\u003cbr\u003e • Allows expansion\/contraction of the cable core\u003cbr\u003e • Improved bending characteristics versus helical copper tape shield\u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Class 10,000 environment utilized for cable core material handling\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to water treeing\u003cbr\u003e • Clean-stripping insulation shield\u003cbr\u003e • Sunlight-resistant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e:\u003cbr\u003e • Normal - 90°C\u003cbr\u003e • Emergency* - 130°C\u003cbr\u003e • Short Circuit - 250°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Copper conductors\u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610\u003cbr\u003e • BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT\u003cbr\u003e • TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core\/LACT 3. sealed overlap and blocked LACT\/jacket\u003cbr\u003e • Sealed LACT overlap\u003cbr\u003e • True Triple Extrusion\u003cbr\u003e • Low-strip insulation shield\u003cbr\u003e • Red stripes on jacket\u003cbr\u003e • Semi-conducting thermoplastic jacket\u003cbr\u003e • 3 X 1\/C triplex or parallel\u003cbr\u003e • Type MV-90 UL 1072\u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating\u003cbr\u003e • UL Listed\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor (no. of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (min. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (max. insulation)\u003c\/td\u003e\n\u003ctd\u003e1.520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - thkn.)\u003c\/td\u003e\n\u003ctd\u003e0.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lact shield - o.d.)\u003c\/td\u003e\n\u003ctd\u003e1.632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1) inches (lldpe jacket)\u003c\/td\u003e\n\u003ctd\u003e1.852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn. inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (al cond)\u003c\/td\u003e\n\u003ctd\u003e703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003epprox. weight (1) lb\/1000 ft (cu shield)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft (total)\u003c\/td\u003e\n\u003ctd\u003e1830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (direct buried)\u003c\/td\u003e\n\u003ctd\u003e665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2) (in duct)\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129870762047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_2e1c2fc2-f7e8-4ec3-af5a-30a7d818eb3e.jpg?v=1571726278"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/Nassau-lg_1_fc2b9e7b-9281-44f4-8879-8317cab57b1b.jpg?v=1523862391","url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-empowr%c2%ae-15-kv-longitudinally-applied-corrugated-tape-lldpe-jacket-link-and-shielded-power-cable-al-conductor-trxlpe-insulation.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}