{"title":"General Cable Control Cable Multi-Conductor Overall Shield 600V VW-1 UL Type TC-ER* ULTROL 60®+","description":"","products":[{"product_id":"general-cable-control-cable-multi-conductor-overall-shield-600v-vw-1-ul-type-tc-er-ultrol-60®","title":"General Cable Control Cable Multi-Conductor Overall Shield 600V VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThis control cable multi-conductortype TC-ER is made of tinned annealed copper. It is designed to ensure long term thermal and moisture endurance. The tin coating of the tray copper cable prevents oxidation at high temperatures. And, because it is ER rated, it means users can save money on their cable installations. The tray cables have passed additional crush and impact tests meaning they will not be damaged when used as opening wiring. There is no need for armoring and it can be used outside of conduit or some other raceway. The tinned annealed copper cable allows for easy workability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications :\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required Can be installed in trays, conduit, ducts, or in direct burial applications\u003cbr\u003e • It is designed for applications such as in nuclear generating stations and other uses where flame retardancy is essential. It may also be installed in direct burial applications, in trays, in ducts, and in conduits. In situations where Class 1E circuits need greater performance, these conductors may be used, especially if there is need to shield them from interference by external electrostatic. It may also be used in petrochemical, pulp and paper industry, steel milling and mining industry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant, heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003cbr\u003e • This tray cable has the ability to resist flames and moisture. It is also resistant to radiation, something that makes it ideal for use in nuclear generating stations. A cross-linked polyethylene material ensures optimal protection against damage caused by moisture, heat, or flames.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Jacket :\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant, moisture-, oil-, sunlight and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003cbr\u003e • The jacket is resistant to sunlight, moisture, and radiation. Its thermoset material offers great mechanical strength and improved circuit integrity. The thermoset material makes it resistant to chemicals such as oil.\u003c\/p\u003e\n\u003cdiv class=\"siraj\" style=\"font-weight: bold;\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCond. Size (AWG)\u003c\/td\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003eNet Weight Kg\/Km\u003c\/td\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003ctd\u003e30060.14.2\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-2-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003ctd\u003e30060.14.3\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-3-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e199\u003c\/td\u003e\n\u003ctd\u003e30060.14.4\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-4-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e227\u003c\/td\u003e\n\u003ctd\u003e30060.14.5\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-5-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003ctd\u003e30060.14.7\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-7-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e30060.14.9\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-9-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e524\u003c\/td\u003e\n\u003ctd\u003e30060.14.12\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-12-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e812\u003c\/td\u003e\n\u003ctd\u003e30060.14.19\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-19-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e1005\u003c\/td\u003e\n\u003ctd\u003e30060.14.25\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-25-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e1268\u003c\/td\u003e\n\u003ctd\u003e30060.14.30\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-30-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1570\u003c\/td\u003e\n\u003ctd\u003e30060.14.37\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-14-37-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e30060.12.2\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-2-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003ctd\u003e30060.12.3\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-3-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e295\u003c\/td\u003e\n\u003ctd\u003e30060.12.4\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-4-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e341\u003c\/td\u003e\n\u003ctd\u003e30060.12.5\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-5-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e453\u003c\/td\u003e\n\u003ctd\u003e30060.12.7\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-7-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e587\u003c\/td\u003e\n\u003ctd\u003e30060.12.9\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-9-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e736\u003c\/td\u003e\n\u003ctd\u003e30060.12.12\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-12-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e1122\u003c\/td\u003e\n\u003ctd\u003e30060.12.19\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-19-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e1383\u003c\/td\u003e\n\u003ctd\u003e30060.12.25\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-25-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e1599\u003c\/td\u003e\n\u003ctd\u003e30060.12.30\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-30-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1921\u003c\/td\u003e\n\u003ctd\u003e30060.12.37\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-12-37-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003ctd\u003e30060.10.2\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-10-2-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e301\u003c\/td\u003e\n\u003ctd\u003e30060.10.3\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-10-3-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e433\u003c\/td\u003e\n\u003ctd\u003e30060.10.4\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-10-4-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e519\u003c\/td\u003e\n\u003ctd\u003e30060.10.5\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-10-5-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e618\u003c\/td\u003e\n\u003ctd\u003e30060.10.7\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-10-7-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e849\u003c\/td\u003e\n\u003ctd\u003e30060.10.9\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-10-9-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e1055\u003c\/td\u003e\n\u003ctd\u003e30060.10.12\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-10-12-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e1545\u003c\/td\u003e\n\u003ctd\u003e30060.10.19\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/ultrol-60-cable\/control-cable-10-19-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7496923512895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_d497f5d8-0c32-45d7-a82e-d5bda0b93208.jpg?v=1571729665"},{"product_id":"general-cable-control-cable-14-2-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/2 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.359\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e9.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7496975745087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b916aba1-7661-422e-849e-9d4ae13c857e.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-3-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/3 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.379\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e9.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7496977481791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_e3f6783e-7d01-4335-af60-decb18d4edc2.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-4-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/4 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.414\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7496978464831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_aea360df-6e01-408a-80c7-ba47f9993bd3.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-5-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/5 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e0.512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e227\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7496979972159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_15f673fc-080b-4475-8e82-14559f6abf61.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-7-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/7 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.582\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e14.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e146\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7496984166463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_063267bf-fbd2-462d-8934-74742c437f6c.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-9-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/9 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.663\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e16.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7496987541567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_265a0c6a-2621-4327-b8ae-2b049d003489.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-12-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/12 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.736\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e18.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e163\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7496989507647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_93ac85e4-e117-4ac5-b873-6d2dc673ec89.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-19-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/19 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.888\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e22.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e251\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e374\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e546\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e812\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497026043967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_84034e4a-54a6-4053-9707-5cde477137d2.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-25-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/25 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e25.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e491\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497027977279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_8d5ca2bc-fef9-4597-9245-a8daa0fd45db.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-30-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/30 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e27.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e586\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497032630335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b9be4b1e-0ac6-4490-95ab-bc30ebf71bd6.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-14-37-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 14\/37 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.154\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e29.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e484\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.14.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497034301503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_252788a0-3f24-4dd7-b438-a852599eaeba.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-2-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/2 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497096757311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_762b375f-65a3-4cb2-9740-5c6cf1e3d771.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-3-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/3 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497099149375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_215b0828-fa25-4b0c-8ade-bd3a2c15ac70.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-4-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/4 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497101017151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_9ea7f6e8-1681-4ccf-bc9f-c0519d5da1e5.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-5-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/5 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.607\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e15.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e171\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e229\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497101901887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_da828480-f14a-4c14-aa2e-9eb9d2270bcf.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-7-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/7 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.653\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e156\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e453\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497104425023,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_c6d3885e-bbf8-4f1c-8c29-50e09bfa64e6.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-9-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/9 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.745\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e18.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e587\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497105375295,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_60c5295c-f065-49e7-9b61-68ddda61daf5.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-12-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/12 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.828\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e21.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e736\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497122381887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_ec233066-32ff-4e90-b4c5-62e5c796b783.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-19-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/19 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e25.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e597\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497124741183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_29483b4b-6e7e-4c77-a3aa-910a84cae8c3.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-25-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/25 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e29.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e525\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e781\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1383\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497127755839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_009a248e-28ff-4b92-a808-b8248981b957.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-30-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/30 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e30.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e932\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497130999871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_e9ce4fbb-5824-403d-a9a4-af9dec7539b1.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-12-37-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 12\/37 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e33.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e769\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1921\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.12.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497131917375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b49e2152-219a-4285-86f3-51de4a7857be.jpg?v=1571729666"},{"product_id":"general-cable-control-cable-10-2-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 10\/2 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e173\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497481814079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_8face1ce-5f79-4655-b4ff-ce0fcb0a05de.jpg?v=1571729667"},{"product_id":"general-cable-control-cable-10-3-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 10\/3 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.10.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497487253567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_15c989b9-8614-49f3-bc38-d90b82511948.jpg?v=1571729667"},{"product_id":"general-cable-control-cable-10-4-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 10\/4 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e13.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e433\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.10.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497489186879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_eec719bf-d440-4ed5-82a9-0dff0486ef6c.jpg?v=1571729667"},{"product_id":"general-cable-control-cable-10-5-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 10\/5 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.688\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e519\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497495117887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_4c0c4573-d7e8-452b-99d8-17f4afe57c59.jpg?v=1571729667"},{"product_id":"general-cable-control-cable-10-7-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 10\/7 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e18.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e248\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e369\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.10.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497498787903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_8e4bcec6-460c-4da5-a307-727f32dcceef.jpg?v=1571729667"},{"product_id":"general-cable-control-cable-10-9-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 10\/9 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.887\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e22.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e466\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e849\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.10.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497506881599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_60116ba1-ae8b-4a80-bc9c-461b1967147e.jpg?v=1571729667"},{"product_id":"general-cable-control-cable-10-12-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 10\/12 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.982\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e24.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e709\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.10.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497508716607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_98cf3090-3d15-47c1-a0ac-0d0d9723cfd1.jpg?v=1571729667"},{"product_id":"general-cable-control-cable-10-19-gauge-multi-conductor-600v-overall-shield-vw-1-ul-type-tc-er-ultrol-60®","title":"GENERAL CABLE Control Cable 10\/19 Gauge Multi-Conductor 600V Overall Shield VW-1 UL Type TC-ER* ULTROL 60®+","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e14 AWG thru 10 AWG, tinned annealed copper; Class B stranding; 2 thru 37 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant , heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)\u003cbr\u003e • Color code: per ICEA Method 1, Table E-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e Copper\/polyester tape in contact with a stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) —Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrint:\u003c\/strong\u003e GENERAL CABLE (WC) ULTROL® 60+ XX\/C XXAWG COPPER FR-XLPE XLPO SHIELDED 600 V 90°C SUN RES OIL RES I \u0026amp; II DIR BUR (UL) TYPE TC-ER* XHHW-2 VW-1 NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e  • Conductor stranding\u003cbr\u003e  • ISO Metric conductors\u003cbr\u003e  • E-2 color code\u003cbr\u003e  • Longitudinal corrugated tinned copper tape shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • ULTROL® 60+ control cable is a 600 V overall shielded, multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical\u003cbr\u003e • Where optimum performance is required for use on Class 1E circuits when shielding from external electrostatic interference is required\u003cbr\u003e • Can be installed in trays, conduit, ducts, or in direct burial applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Fully traceable\u003cbr\u003e • Qualified for 60-year service life\u003cbr\u003e • Gamma and beta radiation resistant (up to 350 megarads)\u003cbr\u003e • Submergence operability\u003cbr\u003e • Long-term thermal endurance and superior electricals\u003cbr\u003e • Excellent mechanical cut-through properties\u003cbr\u003e • Long-term moisture and radiation stability\u003cbr\u003e • Free stripping for ease of termination\u003cbr\u003e • Meets cold bend test at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • Class 1E Qualified in accordance with IEEE 323-1974\/2003 and IEEE 383-1974\/2003\u003cbr\u003e • ICEA S-73-532\u003cbr\u003e • UL 1277 Type TC-ER*\u003cbr\u003e • UL 44 XHHW-2 * -ER for \u0026gt; 2 conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • IEEE 383:1974\u003cbr\u003e • IEEE 383:2003\u003cbr\u003e • ICEA T-29-520\u003cbr\u003e • IEEE 1202\/FT4-1991, Aged \u0026amp; Unaged\u003cbr\u003e • VW-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther:\u003c\/strong\u003e\u003cbr\u003e • Quality assurance program in accordance with NRC 10CFR50 Appendix B\u003cbr\u003e • ANSI N45.2\u003cbr\u003e • ASME NQA-1\u003cbr\u003e • NIAC\u003cbr\u003e • NUPIC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material to be shipped on non-returnable wooden reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7\/.0385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edrain wire size (awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg. jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cableo.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e28.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e638\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e30060.10.19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7497511501887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_13995b10-43ba-4655-933d-516c6e98b95f.jpg?v=1571729667"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-control-cable-multi-conductor-overall-shield-600v-vw-1-ul-type-tc-er-ultrol-60%c2%ae.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}