{"title":"General Cable Anaconda® Brand Type SHD-GC Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"","products":[{"product_id":"anaconda-brand-type-shd-gc-1-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 1 Gauge Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 1 GAUGE POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 1 GAUGE Anaconda Brand Cable 5000 VOLTS, 1 GAUGE EPR CPE Cable 5000 VOLTS, 1 GAUGE TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/kcmil)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e49.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1248\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1857\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e184\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16201.396409\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161544212543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_2b62601b-1a41-4935-a193-6fc769abe1e1.jpg?v=1571727806"},{"product_id":"anaconda-brand-type-shd-gc-1-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 1\/0 Gauge Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 1\/0 GAUGE POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 1\/0 GAUGE Anaconda Brand Cable 5000 VOLTS, 1\/0 GAUGE EPR CPE Cable 5000 VOLTS, 1\/0 GAUGE TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd. size (awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e5.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal cable 0.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e52.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1533\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper weight(kg\/km)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2281\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4807\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16241.615100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161544441919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_8b6b1373-1ee8-4348-8f26-6115b9cfa0c8.jpg?v=1571727806"},{"product_id":"anaconda-brand-type-shd-gc-2-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 2 Gauge Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 2 GAUGE POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 2 GAUGE Anaconda Brand Cable 5000 VOLTS, 2 GAUGE EPR CPE Cable 5000 VOLTS, 2 GAUGE TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/kcmil)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e47.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1533\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3639\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16202.317964\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161547849791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_7ea8ff82-eabe-4e9a-b001-c12e0f0f6bfc.jpg?v=1571727806"},{"product_id":"anaconda-brand-type-shd-gc-2-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 2\/0 Gauge Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 2\/0 GAUGE POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 2\/0 GAUGE Anaconda Brand Cable 5000 VOLTS, 2\/0 GAUGE EPR CPE Cable 5000 VOLTS, 2\/0 GAUGE TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd. size (awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e5.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal cable 0.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e55.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1854\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper weight(kg\/km)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e5655\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16252.271926\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161548144703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_318bbc31-dd85-4090-b537-25f96d6cfd2a.jpg?v=1571727806"},{"product_id":"anaconda-brand-type-shd-gc-250mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 250MCM Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 250MCM POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 250MCM Anaconda Brand Cable 5000 VOLTS, 250MCM EPR CPE Cable 5000 VOLTS, 250MCM TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd. size (awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e6.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal cable 0.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e68.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper weight(kg\/km)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4970\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e6105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e9085\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16241.216000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161548341311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_a78e7563-69bb-4dc1-b057-3ad6f1467ad9.jpg?v=1571727807"},{"product_id":"anaconda-brand-type-shd-gc-3-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 3\/0 Gauge Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 3\/0 GAUGE POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 3\/0 GAUGE Anaconda Brand Cable 5000 VOLTS, 3\/0 GAUGE EPR CPE Cable 5000 VOLTS, 3\/0 GAUGE TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd. size (awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal cable 0.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e59.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper weight(kg\/km)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3456\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e279\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16241.215300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161548734527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_4d5f5be9-26fe-4376-bfa4-de0b347e0486.jpg?v=1571727807"},{"product_id":"anaconda-brand-type-shd-gc-300mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 300MCM Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 300MCM POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 300MCM Anaconda Brand Cable 5000 VOLTS, 300MCM EPR CPE Cable 5000 VOLTS, 300MCM TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd. size (awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e741\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e6.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal cable 0.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e71.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3962\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper weight(kg\/km)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e5897\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e6875\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e10231\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16241.216300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161548898367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b23e3ea9-eaf4-4463-8cb5-44a7bbc6dd23.jpg?v=1571727807"},{"product_id":"anaconda-brand-type-shd-gc-350mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 350MCM Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 350MCM POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 350MCM Anaconda Brand Cable 5000 VOLTS, 350MCM EPR CPE Cable 5000 VOLTS, 350MCM TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e6 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS): \u003c\/strong\u003eExtruded thermosetting semi-conducting stress control layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Ethylene Propylene Rubber (EPR) insulation colored for contrasting with black conducting layer\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e A flexible coated copper\/textile braid shield is applied over a non-conducting overlapped tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround-Check Conductor: \u003c\/strong\u003eAnnealed copper, rope-lay-stranded per ASTM B172, insulated with high-strength yellow polypropylene\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003e • Coated copper, rope-lay-stranded per ASTM B172\u003cbr\u003e • Two conductors in contact with the flexible copper braid shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eReinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking:\u003c\/strong\u003eGENERAL CABLE® ANACONDA® BRAND (SIZE) 3\/C TYPE SHD-GC 5000 VOLTS P-7K-102-046 MSHA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e • Colored jackets are available\u003cbr\u003e • TPU (Thermoplastic Polyurethane) jacket\u003cbr\u003e • Anamaxx® jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Designed for use as a trailing cable on AC mining equipment:\u003cbr\u003e  - Where service conditions are severe and maximum safety is mandatory (such as power shovels and draglines in open-pit mines, quarries, gantry cranes and slag reclaiming)\u003cbr\u003e  - For high-voltage distribution in underground mines where frequent relocation is necessary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Simultaneous extrusion and vulcanization of both strand shield and insulation form a virtually perfect electrode, eliminating unequal electrical stresses\u003cbr\u003e • Excellent heat, moisture, steam, oil, corona, chemical and radiation resistance\u003cbr\u003e • Flexible for easy handling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Resists cutting, impact, abrasion, flame and sunlight\u003cbr\u003e • Excellent thermal stability and physical properties over a broad temperature range\u003cbr\u003e • Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications\u003cbr\u003e • Meets flame test requirements and is accepted for listing by MSHA\u003cbr\u003e • Approved by the Pennsylvania Department of Environmental Protection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003eMaterial cut to length and shipped on nonreturnable reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd. size (awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal cable 0.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e74.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper weight(kg\/km)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e6730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e7795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e11600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16262.687414\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161549029439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_4a302084-859b-4791-9127-4a71771b5ecb.jpg?v=1571727807"},{"product_id":"anaconda-brand-type-shd-gc-4-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 4 Gauge Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 4 GAUGE POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 4 GAUGE Anaconda Brand Cable 5000 VOLTS, 4 GAUGE EPR CPE Cable 5000 VOLTS, 4 GAUGE TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/kcmil)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e4.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e42.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1072\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1895\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16204.858221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161549258815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_6ab45af5-cdad-4c26-abc8-848f57f859f0.jpg?v=1571727807"},{"product_id":"anaconda-brand-type-shd-gc-4-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 4\/0 Gauge Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 4\/0 GAUGE POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 4\/0 GAUGE Anaconda Brand Cable 5000 VOLTS, 4\/0 GAUGE EPR CPE Cable 5000 VOLTS, 4\/0 GAUGE TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd. size (awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e532\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal cable 0.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e63.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2936\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper weight(kg\/km)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4369\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e5265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e7835\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16254.730315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161552240703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_56ab2405-0084-4ebc-a288-1762ff647bf4.jpg?v=1571727807"},{"product_id":"anaconda-brand-type-shd-gc-500mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 500MCM Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 500MCM POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 500MCM Anaconda Brand Cable 5000 VOLTS, 500MCM EPR CPE Cable 5000 VOLTS, 500MCM TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd. size (awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e1221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e7.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal cable 0.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3.31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e84.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e6515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper weight(kg\/km)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e9696\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e10415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e15499\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e536\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16265.570479\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161552764991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_f079ea5e-36b9-487e-9e28-2a80d7fb4a49.jpg?v=1571727807"},{"product_id":"anaconda-brand-type-shd-gc-6-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC 6 Gauge Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC 6 GAUGE POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, 6 GAUGE Anaconda Brand Cable 5000 VOLTS, 6 GAUGE EPR CPE Cable 5000 VOLTS, 6 GAUGE TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground-check conductor.  The cable employ coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  Each phase conductor is wrapped in an extruding thermosetting semi-conducting stress control layer.  The copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated in yellow polypropylene.  A flexible braided copper insulation shield is applied over a non-conducting overlapped tape.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda® Brand Type SHD-GC Power Shielded Round Portable W\/Ground Check EPR CPE 5000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type SHD-GC cables are used in low and medium voltage AC circuits. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets FT-5 flame test, a  UL vertical flame test of 1,700 BTU.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/kcmil)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd. cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e4.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e39.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e540\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1560\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16241.210600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161552994367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_60f58d4e-7157-4b1a-bc75-39700a66303d.jpg?v=1571727807"},{"product_id":"anaconda-brand-type-shd-gc-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor","title":"General Cable Anaconda® Brand Type SHD-GC Power Shielded Round Portable w\/Ground-Check EPR CPE 5000 Volts Three Conductor","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our ANACONDA BRAND TYPE SHD-GC POWER SHIELDED ROUND PORTABLE W\/GROUND-CHECK EPR CPE 5000 VOLTS THREE CONDUCTOR. Excellent Heat, Moisture, Steam, Oil, Corona, Chemical and Radiation Resistance.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable 5000 VOLTS, Anaconda Brand Cable 5000 VOLTS, EPR CPE Cable 5000 VOLTS, TYPE SHD-GC Cable, Power Shielded Round Portable Cable, Mining Cable W\/GROUND-CHECK EPR.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e6 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS): \u003c\/strong\u003eExtruded thermosetting semi-conducting stress control layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Ethylene Propylene Rubber (EPR) insulation colored for contrasting with black conducting layer\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e A flexible coated copper\/textile braid shield is applied over a non-conducting overlapped tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround-Check Conductor: \u003c\/strong\u003eAnnealed copper, rope-lay-stranded per ASTM B172, insulated with high-strength yellow polypropylene\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003e • Coated copper, rope-lay-stranded per ASTM B172\u003cbr\u003e • Two conductors in contact with the flexible copper braid shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eReinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003eGENERAL CABLE® ANACONDA® BRAND (SIZE) 3\/C TYPE SHD-GC 5000 VOLTS P-7K-102-046 MSHA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cbr\u003e • Colored jackets are available\u003cbr\u003e • TPU (Thermoplastic Polyurethane) jacket\u003cbr\u003e • Anamaxx® jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Designed for use as a trailing cable on AC mining equipment:\u003cbr\u003e  - Where service conditions are severe and maximum safety is mandatory (such as power shovels and draglines in open-pit mines, quarries, gantry cranes and slag reclaiming)\u003cbr\u003e  - For high-voltage distribution in underground mines where frequent relocation is necessary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Simultaneous extrusion and vulcanization of both strand shield and insulation form a virtually perfect electrode, eliminating unequal electrical stresses\u003cbr\u003e • Excellent heat, moisture, steam, oil, corona, chemical and radiation resistance\u003cbr\u003e • Flexible for easy handling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Resists cutting, impact, abrasion, flame and sunlight\u003cbr\u003e • Excellent thermal stability and physical properties over a broad temperature range\u003cbr\u003e • Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications\u003cbr\u003e • Meets flame test requirements and is accepted for listing by MSHA\u003cbr\u003e • Approved by the Pennsylvania Department of Environmental Protection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on nonreturnable reels\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size\u003cbr\u003e (awg \/Kcmil)\u003c\/td\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003egeneral cable and\u003cbr\u003e anaconda brand\u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-6-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-t\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003ctd\u003e16241.210600\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-6-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-t\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-4-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-t\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003ctd\u003e16204.858221\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-4-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-t\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-2-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-t\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e16202.317964\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-2-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-t\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-1-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-t\"\u003e1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e184\u003c\/td\u003e\n\u003ctd\u003e16201.396409\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-1-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-t\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-1-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e211\u003c\/td\u003e\n\u003ctd\u003e16241.615100\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-1-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-2-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts\"\u003e2\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003ctd\u003e16252.271926\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-2-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-3-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts\"\u003e3\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e279\u003c\/td\u003e\n\u003ctd\u003e16241.215300\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-3-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-4-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e321\u003c\/td\u003e\n\u003ctd\u003e16254.730315\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-4-0-gauge-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-250mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-th\"\u003e250\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e355\u003c\/td\u003e\n\u003ctd\u003e16241.216000\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-250mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-th\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-300mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-th\"\u003e300\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e398\u003c\/td\u003e\n\u003ctd\u003e16241.216300\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-300mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-th\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-350mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-th\"\u003e350\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e435\u003c\/td\u003e\n\u003ctd\u003e16262.687414\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-350mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-th\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-500mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-th\"\u003e500\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e536\u003c\/td\u003e\n\u003ctd\u003e16265.570479\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/mining-cable-g-gg-c-and-dlo-and-mp-gc-and-shd-gc-and-magnet\/type-shd\/anaconda-brand-type-shd-gc-500mcm-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-th\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161559482431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_cc268278-9985-4020-9d3f-a2e26bfd62ce.jpg?v=1571727810"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-anaconda%c2%ae-brand-type-shd-gc-power-shielded-round-portable-w-ground-check-epr-cpe-5000-volts-three-conductor.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}