{"title":"Flexible HydroFlex Rubber Submersible Pump Cable","description":"","products":[{"product_id":"flexible-hydroflex-rubber-submersible-pump-cable","title":"Flexible HydroFlex Rubber Submersible Pump Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThere are certain locations with cold weather and high ampacity requirements, these areas call for a specialized cable designed to fit such applications. It should be necessary to consider this cable if you want a submersible pump cable that can work well for you in cold locations. Besides, the flexibility of the cable allows it to be also used in mining applications. One key feature for a cable to be used in these harsh and intolerable conditions is the cable’s capacity to provide adequate security to the system. Of course this security comes by a sturdy insulation system.\u003c\/p\u003e\n\u003cp\u003eThe Hydroflex cable has three conductors without ground. It is appropriate for 600 to 2000 volts loads. This Flat Rubber Submersible Pump Cable is for use within well casings to do wiring for submersible water pumps in deep wells. Its capacity to defy all odds and do well in these adverse conditions is because of the strong insulation made from Ethylene Propylene Rubber. This insulation is augmented with a sturdy outer jacket made of Chlorinated Polyethylene Rubber. When we talk of the cable being appropriate for low temperatures, we mean a temperature as low as -40 degrees Celsius. This cable is good for you and Nassau does well by providing a wide range of sizes of this cable such as from 4 to 500 MCM.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize AWG\/kcmil\u003c\/td\u003e\n\u003ctd\u003eno. of conductors in cable\u003c\/td\u003e\n\u003ctd\u003eWeight Per 1000ft Total (Lbs.)\u003c\/td\u003e\n\u003ctd\u003eAllow-Able Amp-Acity 30C (Amps)\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-4-gauge\"\u003e4\/3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e806\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-4-gauge\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-2-gauge\"\u003e2\/3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1209\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-2-gauge\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-1-0-gauge\"\u003e1\/0-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1867\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-1-0-gauge\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-2-0-gauge\"\u003e2\/0-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2172\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-2-0-gauge\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.nassauelectrical.com\/products\/submersible-pump-cable\/3-0-3-w-grnd-hydroflex-pump\"\u003e3\/0-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2569\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"https:\/\/www.nassauelectrical.com\/products\/submersible-pump-cable\/3-0-3-w-grnd-hydroflex-pump\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-4-0-gauge\"\u003e4\/0-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2842\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-4-0-gauge\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-250-mcm\"\u003e250-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3894\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-250-mcm\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-350-mcm\"\u003e350-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e5106\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-350-mcm\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-500-mcm\"\u003e500-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e6920\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-500-mcm\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-4-gauge-1\"\u003e4\/3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1118\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-4-gauge-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-2-gauge-1\"\u003e2\/3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1470\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-2-gauge-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-1-0-gauge-1\"\u003e1\/0-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2270\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-1-0-gauge-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-2-0-gauge-1\"\u003e2\/0-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2710\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-2-0-gauge-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.nassauelectrical.com\/products\/submersible-pump-cable\/3-0-3-w-grnd-hydroflex-pump-1\"\u003e3\/0-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3240\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"https:\/\/www.nassauelectrical.com\/products\/submersible-pump-cable\/3-0-3-w-grnd-hydroflex-pump-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-4-0-gauge-1\"\u003e4\/0-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3615\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-4-0-gauge-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-250-mcm-1\"\u003e250-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4990\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-250-mcm-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-350-mcm-1\"\u003e350-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e6450\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-350-mcm-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-500-mcm-1\"\u003e500-3 W\/GRND Hydroflex Pump\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e8533\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/subhydro-500-mcm-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130081460287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable.jpg?v=1571726344"},{"product_id":"1-0-3-w-grnd-hydroflex-pump","title":"1\/0-3 W\/GRND Hydroflex Pump","description":"\n\n    \n        \u003ctitle\u003e1\/0-3 W\/GRND Hydroflex Pump\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"The Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"1\/0-3 W\/GRND Hydroflex Pump, Submersible Cable, Hydroflex Rubber Submersible Pump Cable, Pump Cable, Submersible Pump Cable, Insulated Cable, Jacketed Cable, XLPE Cable, Multi-Conductor Cable, Type MC Cable\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors. \n                The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per\n                specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed\n                copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant\n                ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves\n                to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene\n                propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation. \n                A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump\n                Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable\n                being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in\n                pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor\n                or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eIn\n                accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM\n                standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThis\n                product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThe\n                copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n                \u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n                \u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n                \u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the\n                    phase conductors.\u003c\/li\u003e\n                \u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n                \u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n                \u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n                \u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cbr\u003e\n            \u003cbr\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003eN\/A\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e1\/0\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e414 x 0.0159\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e1.98 x 0.87\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e50.4 x 22.1\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e1867\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e170\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n            \u003cp\u003e \u003c\/p\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160174149695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_dec35943-6c9d-4f90-8b5f-9285df8b1308.jpg?v=1571727575"},{"product_id":"2-0-3-w-grnd-hydroflex-pump","title":"2\/0-3 W\/GRND Hydroflex Pump","description":"\n\n    \n        \u003ctitle\u003e2\/0-3 W\/GRND Hydroflex Pump\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"he Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"2\/0-3 W\/GRND Hydroflex Pump, Submersible Cable, Hydroflex Rubber Submersible Pump Cable, Pump Cable, Submersible Pump Cable, Insulated Cable, Jacketed Cable, XLPE Cable, Multi-Conductor Cable, Type MC Cable\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors. \n                The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per\n                specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed\n                copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant\n                ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves\n                to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene\n                propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation. \n                A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump\n                Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable\n                being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in\n                pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor\n                or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eIn\n                accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM\n                standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThis\n                product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThe\n                copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n                \u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n                \u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n                \u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the\n                    phase conductors.\u003c\/li\u003e\n                \u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n                \u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n                \u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n                \u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cbr\u003e\n            \u003cbr\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003eN\/A\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2\/0\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e522 x 0.0159\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2.13 x 0.92\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e54.0 x 23.3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2172\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e195\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n            \u003cp\u003e \u003c\/p\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160351653951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_708fa61d-1f6d-4398-9cc3-f8d184f5d691.jpg?v=1571727644"},{"product_id":"2-3-w-grnd-hydroflex-pump","title":"2\/3 W\/GRND Hydroflex Pump","description":"\n\n    \n        \u003ctitle\u003e2\/3 W\/GRND Hydroflex Pump\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Extra Flexible, High Ampacity, Flat Rubber Submersible Pump Cable for use within well casings for wiring deep-well submersible water pumps, mining applications. Hydroflex is especially efficient for use in municipal applications, cold weather and high ampacity requirements\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"2\/3 W\/GRND Hydroflex Pump, Submersible Cable, Hydroflex Rubber Submersible Pump Cable, Pump Cable, Submersible Pump Cable, Insulated Cable, Jacketed Cable, XLPE Cable, Multi-Conductor Cable, Type MC Cable\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003eN\/A\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e259 x 0.0159\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e1.65 x 0.72\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e41.8 x 18.2\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e1209\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e130\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n            \u003cp\u003eFLAT SUBMERSIBLE PUMP CABLE EXTRA FLEXIBLE HYDROFLEX 600\/2000 VOLTS, 3 CONDUCTOR WITH OR WITHOUT GROUND.\n                \u003cbr\u003e Extra Flexible, High Ampacity, Flat Rubber Submersible Pump Cable for use within well casings for wiring deep-well submersible water pumps,\n                mining applications. Hydroflex is especially efficient for use in municipal applications, cold weather and high ampacity requirements.\n                \u003cbr\u003e VOLTAGE: 600\/2kV\n                \u003cbr\u003e INSULATION: EPR - Ethylene Propylene Rubber\n                \u003cbr\u003e OUTER JACKET: CPE - Chlorinated Polyethylene Rubber\n                \u003cbr\u003e SIZES: 4 - 500 MCM\n                \u003cbr\u003e TEMP DRY\/WET: 90°C Dry, 90°C Wet, Min. Ambient Temp. -40°C\u003c\/p\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160360304703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_b04c8394-9dd5-4368-8adb-1a7282fcec15.jpg?v=1571727646"},{"product_id":"250-3-w-grnd-hydroflex-pump","title":"250-3 W\/GRND Hydroflex Pump","description":"\n\n    \n        \u003ctitle\u003e250-3 W\/GRND Hydroflex Pump\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"The Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  \"\u003e\n        \u003cmeta name=\"Keywords\" content=\"250-3 W\/GRND Hydroflex Pump, Submersible Cable, Hydroflex Rubber Submersible Pump Cable, Pump Cable, Submersible Pump Cable, Insulated Cable, Jacketed Cable, XLPE Cable, Multi-Conductor Cable, Type MC Cable\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors. \n                The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per\n                specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed\n                copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant\n                ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves\n                to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene\n                propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation. \n                A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump\n                Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable\n                being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in\n                pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor\n                or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eIn\n                accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM\n                standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThis\n                product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThe\n                copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n                \u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n                \u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n                \u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the\n                    phase conductors.\u003c\/li\u003e\n                \u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n                \u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n                \u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n                \u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cbr\u003e\n            \u003cbr\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003eN\/A\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e250\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e973 x 0.0159\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2.93 x 1.33\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e74.6 x 33.9\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3894\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e290\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n            \u003cp\u003e \u003c\/p\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160416567359,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_45498dfc-0a6b-46c3-abe2-4d2975607311.jpg?v=1571727670"},{"product_id":"3-0-3-w-grnd-hydroflex-pump","title":"3\/0-3 W\/GRND Hydroflex Pump","description":"\n\n    \n        \u003ctitle\u003e3\/0-3 W\/GRND Hydroflex Pump\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"3\/0-3 W\/GRND Hydroflex Pump, Submersible Cable, Hydroflex Rubber Submersible Pump Cable, Pump Cable, Submersible Pump Cable, Insulated Cable, Jacketed Cable, XLPE Cable, Multi-Conductor Cable, Type MC Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"The Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors. \n                The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per\n                specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed\n                copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant\n                ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves\n                to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene\n                propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation. \n                A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump\n                Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable\n                being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in\n                pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor\n                or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eIn\n                accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM\n                standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThis\n                product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThe\n                copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n                \u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n                \u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n                \u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the\n                    phase conductors.\u003c\/li\u003e\n                \u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n                \u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n                \u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n                \u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cbr\u003e\n            \u003cbr\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003eN\/A\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\/0\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e734 x 0.0159\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2.24 x 1.02\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e57.0 x 26.9\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2569\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e230\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n            \u003cp\u003e \u003c\/p\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160429903935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_1c6ce00b-0b49-4c70-b8e9-bd50c754884a.jpg?v=1571727672"},{"product_id":"350-3-w-grnd-hydroflex-pump","title":"350-3 W\/GRND Hydroflex Pump","description":"\n\n    \n        \u003ctitle\u003e350-3 W\/GRND Hydroflex Pump\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"The Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"350-3 W\/GRND Hydroflex Pump, Submersible Cable, Hydroflex Rubber Submersible Pump Cable, Pump Cable, Submersible Pump Cable, Insulated Cable, Jacketed Cable, XLPE Cable, Multi-Conductor Cable, Type MC Cable\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors. \n                The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per\n                specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed\n                copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant\n                ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves\n                to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene\n                propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation. \n                A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump\n                Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable\n                being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in\n                pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor\n                or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eIn\n                accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM\n                standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThis\n                product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThe\n                copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n                \u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n                \u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n                \u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the\n                    phase conductors.\u003c\/li\u003e\n                \u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n                \u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n                \u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n                \u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cbr\u003e\n            \u003cbr\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003eN\/A\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e350\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e361 x 0.0159\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3.15 x 1.41\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e80.0 x 35.8\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e5106\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e350\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n            \u003cp\u003e \u003c\/p\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160436424767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_grande_600x_094f131f-e80c-40bf-bd03-37c4c33bed9e.jpg?v=1571727674"},{"product_id":"4-0-3-w-grnd-hydroflex-pump","title":"4\/0-3 W\/GRND Hydroflex Pump","description":"\n\n    \n        \u003ctitle\u003e4\/0-3 W\/GRND Hydroflex Pump\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"The Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"4\/0-3 W\/GRND Hydroflex Pump, Submersible Cable, Hydroflex Rubber Submersible Pump Cable, Pump Cable, Submersible Pump Cable, Insulated Cable, Jacketed Cable, XLPE Cable, Multi-Conductor Cable, Type MC Cable\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors. \n                The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per\n                specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed\n                copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant\n                ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves\n                to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene\n                propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation. \n                A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump\n                Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable\n                being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in\n                pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor\n                or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eIn\n                accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM\n                standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThis\n                product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThe\n                copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n                \u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n                \u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n                \u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the\n                    phase conductors.\u003c\/li\u003e\n                \u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n                \u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n                \u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n                \u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cbr\u003e\n            \u003cbr\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003eN\/A\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e4\/0\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e829 x 0.0159\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2.36 x 1.14\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e60.0 x 29.0\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2842\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e260\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n            \u003cp\u003e \u003c\/p\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160455790655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_97e33706-5f93-4e52-9a3f-f2c9bf21e532.jpg?v=1571727677"},{"product_id":"4-3-w-grnd-hydroflex-pump","title":"4\/3 W\/GRND Hydroflex Pump","description":"\u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.  A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n\u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n\u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n\u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n\u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n\u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e412 x 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.43 x 0.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.4 x 17.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e806\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160457953343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_950ecc17-0dd5-4147-9269-f508fd79054c.jpg?v=1571727697"},{"product_id":"500-3-w-grnd-hydroflex-pump","title":"500-3 W\/GRND Hydroflex Pump","description":"\n\n    \n        \u003ctitle\u003e500-3 W\/GRND Hydroflex Pump\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"The Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"500-3 W\/GRND Hydroflex Pump, Submersible Cable, Hydroflex Rubber Submersible Pump Cable, Pump Cable, Submersible Pump Cable, Insulated Cable, Jacketed Cable, XLPE Cable, Multi-Conductor Cable, Type MC Cable\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors. \n                The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per\n                specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed\n                copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant\n                ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves\n                to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene\n                propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation. \n                A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump\n                Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable\n                being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in\n                pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor\n                or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eIn\n                accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM\n                standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThis\n                product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003eThe\n                copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n                \u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n                \u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n                \u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the\n                    phase conductors.\u003c\/li\u003e\n                \u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n                \u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n                \u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n                \u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style='font-stretch: normal; font-size: 7pt; font-family: \"times new roman\";'\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\n            \u003c\/p\u003e\n            \u003cul\u003e\n                \u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cbr\u003e\n            \u003cbr\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003eN\/A\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e500\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e1921 x 0.0159\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3.74 x 1.56\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e95.1 x 39.7\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e6920\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e430\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n            \u003cp\u003e \u003c\/p\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160483774527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_ba82725f-d244-43e4-aa51-c58a2fe41416.jpg?v=1571727700"},{"product_id":"4-3-w-grnd-hydroflex-pump-6-ground-awg","title":"4\/3 W\/GRND Hydroflex Pump 6 Ground AWG","description":"\u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.  A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n\u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n\u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n\u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n\u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n\u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e412 x 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.83 x 0.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46.4 x 17.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7302506643519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_grande_4b2c5e6a-caf7-4042-a903-df847da52a94.jpg?v=1571729393"},{"product_id":"2-3-w-grnd-hydroflex-pump-5-ground-awg","title":"2\/3 W\/GRND Hydroflex Pump 5 Ground AWG","description":"\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e259 x 0.0159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.04 x 0.72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.8 x 18.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFLAT SUBMERSIBLE PUMP CABLE EXTRA FLEXIBLE HYDROFLEX 600\/2000 VOLTS, 3 CONDUCTOR WITH OR WITHOUT GROUND.\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eExtra Flexible, High Ampacity, Flat Rubber Submersible Pump Cable for use within well casings for wiring deep-well submersible water pumps, mining applications. Hydroflex is especially efficient for use in municipal applications, cold weather and high ampacity requirements.\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eVOLTAGE: 600\/2kV\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eINSULATION: EPR - Ethylene Propylene Rubber\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eOUTER JACKET: CPE - Chlorinated Polyethylene Rubber\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eSIZES: 4 - 500 MCM\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eTEMP DRY\/WET: 90°C Dry, 90°C Wet, Min. Ambient Temp. -40°C\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7302741295167,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_grande_527c1c4e-3220-4263-8637-c055c740bf43.jpg?v=1571729393"},{"product_id":"1-0-3-w-grnd-hydroflex-pump-3-ground-awg","title":"1\/0-3 W\/GRND Hydroflex Pump 3 Ground AWG","description":"\u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.  A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThis product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n\u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n\u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n\u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n\u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n\u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e414 x 0.0159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 x 0.87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64.4 x 22.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7302816956479,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_grande_e184ce91-12ae-4c6e-b8ec-72316bf5a1de.jpg?v=1571729393"},{"product_id":"2-0-3-w-grnd-hydroflex-pump-2-ground-awg","title":"2\/0-3 W\/GRND Hydroflex Pump 2 Ground AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.  A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThis product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n\u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n\u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n\u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n\u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n\u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e522 x 0.0159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.75 x 0.92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.8 x 23.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7302855360575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_grande_600x_cf2e4586-10c6-4eaf-a8d0-ddffee5202a3.jpg?v=1571729394"},{"product_id":"3-0-3-w-grnd-hydroflex-pump-1","title":"3\/0-3 W\/GRND Hydroflex Pump 1 Ground AWG","description":"\u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.  A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThis product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n\u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n\u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n\u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n\u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n\u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e734 x 0.0159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.01 x 1.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77.8 x 26.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7302910017599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_grande_47d52531-c234-4061-9d79-7afbfe2b38c9.jpg?v=1571729394"},{"product_id":"4-0-3-w-grnd-hydroflex-pump-1-0-ground-awg","title":"4\/0-3 W\/GRND Hydroflex Pump 1\/0 Ground AWG","description":"\u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.  A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThis product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n\u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n\u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n\u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n\u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n\u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e829 x 0.0159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.39 x 1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86.0 x 29.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7302980993087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_grande_3ba8ffdd-9e84-484d-84ad-62b6a35c19f1.jpg?v=1571729394"},{"product_id":"250-3-w-grnd-hydroflex-pump-2-0-ground-awg","title":"250-3 W\/GRND Hydroflex Pump 2\/0 Ground AWG","description":"\u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.  A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThis product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n\u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n\u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n\u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n\u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n\u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e973 x 0.0159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.92 x 1.33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.6 x 33.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7303045808191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_grande_5072fa8f-d6d5-42ae-8499-9558b7a5df1f.jpg?v=1571729394"},{"product_id":"350-3-w-grnd-hydroflex-pump-1","title":"350-3 W\/GRND Hydroflex Pump","description":"\u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.  A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThis product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n\u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n\u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n\u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n\u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n\u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e361 x 0.0159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.22 x 1.41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e107.2 x 35.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau Electrical","offers":[{"title":"Default Title","offer_id":7303057539135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/submersible.jpg?v=1571729394"},{"product_id":"500-3-w-grnd-hydroflex-pump-250-ground-awg","title":"500-3 W\/GRND Hydroflex Pump 250 Ground AWG","description":"\u003cp\u003eFlexible Hydroflex Rubber Submersible Pump Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Hydroflex Rubber Submersible Pump Cable is a multiconductor cable that features soft bare, annealed rope-lay-stranded copper conductors.  The cable comes with the option of two or three phase conductors plus a ground conductor.  The annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.  The benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product.  The conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).  The cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.  Like the phase conductors the ground conductor is insulated with ethylene propylene rubber.  The insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.  A black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable’s flat construction allows this cable to be used in several types of heavy-duty applications.   The Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/ Ground is typically used in fresh and salt water pump applications where there is a high risk of the cable being crushed or impacted.  The cable is approved to carry ampacities of up to and including 600 volts.  The cable is used in pools, fountains, and sprinkler systems.  It is also used in well casings or deep well wiring systems.  It can be used for indoor or outdoor applications and holds a maximum temperature rating of 90°C in wet or dry conditions. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials, the conductive components meet or exceed ASTM standard B-172 which sets standards for flexible, rope-lay-stranded copper.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThis product aligns with UL standard 62, a standard that sets the requirements for flexible service cords.\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe copper components of the cable meet or exceed ASTM standard B-33; a specification for annealed copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis cable features soft bare, annealed rope-lay-stranded copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper are rated Class K per specifications set by the American Society for Testing and Materials.\u003c\/li\u003e\n\u003cli\u003eThe benefit of Class K copper is the combination of annealed copper with rope-lay-stranded construction to create a flexible product. \u003c\/li\u003e\n\u003cli\u003eThe cable come with the option of two or three conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with moisture and heat resistant ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes a soft bare, annealed copper rope-lay-stranded ground conductor which serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003cli\u003eLike the phase conductors the ground conductor is insulated with ethylene propylene rubber. \u003c\/li\u003e\n\u003cli\u003eThe ground conductor is colored green for identification.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulated phase conductors and ground conductors are assembled in a parallel side-by-side orientation.\u003c\/li\u003e\n\u003cli\u003eThe cable’s flat construction provides maximum crush and impact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eColor Coding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe color coding for the 2 conductor plus ground cable is; black, yellow, and green.\u003c\/li\u003e\n\u003cli\u003eThe color coding for the 3 conductor plus ground cable is; black, yellow, red, and green.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA black, extra heavy-duty thermoplastic elastomer (TPE) jacket covers the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1921 x 0.0159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.83 x 1.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122.8 x 39.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8533\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7303152074815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-flexible-hydroflex-rubber-submersible-pump-cable_grande_99730354-f4e4-4dd9-9d2a-951936868c9f.jpg?v=1571729394"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/flexible-hydroflex-rubber-submersible-pump-cable.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}