{"title":"Multi Conductor Flat Submersible Pump Cable","description":"","products":[{"product_id":"heavy-duty-flat-submersible-well-pump-cable-600v","title":"Heavy Duty Flat Submersible Well Pump Cable W\/Ground 600V","description":"\u003cp\u003eThe Flat Submersible Pump Cable is appropriate for use within the well casings for wiring deep wells with either fresh or salt water submersible pumps. With its proper design with adequate insulation system from polyvinyl chloride and nylon, the cable has all it takes to serve your submerged pump without fear of breakdown.\u003c\/p\u003e\n\u003cp\u003eA good conductor cable must bear all that is required for good and appropriate conduction. One of the key features of a good cable is its efficiency of conduction. This cable is made from soft and bare class C copper material. It is this copper, a leading conductor, which makes this cable an exceptional cable for you. The design of the cable using copper is within the confines of ASTM B3 provisions. With a huge range of sizes from 14 to 500 MCM, you stand a chance to get any size of this cable that fits for you.\u003c\/p\u003e\n\u003cp\u003eTalk of its insulation, the cable has an insulation system which is heat and moisture resistant. The polyvinyl chloride used in this making meets the requirements of the UL 83 for type THHN and THWN cables. This insulation is thick enough to allow no moisture or any other interfering agent into the wire. Being suitable for use in both wet and dry conditions with up to a maximum temperature of 90 degrees Celsius, there are few cables with these capabilities.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor Size AWG\u003c\/td\u003e\n\u003ctd\u003eno. of Isolated conductors\u003c\/td\u003e\n\u003ctd\u003eCable Weight lb\/mft\u003c\/td\u003e\n\u003ctd\u003eAmpacity (1) 40 Degrees C\u003cbr\u003e  Ambient Temp\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-14-awg-2-conductors\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-14-awg-2-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-12-awg-2-conductors\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-12-awg-2-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-10-awg-2-conductors\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-10-awg-2-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-14-awg-3-conductors\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-14-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-12-awg-3-conductors\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e138\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-12-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-10-awg-3-conductors\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-10-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-8-awg-3-conductors\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-8-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-6-awg-3-conductors\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e487\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-6-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-4-awg-3-conductors\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e721\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-4-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-2-awg-3-conductors\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1061\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-2-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-1-awg-3-conductors\"\u003e1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1829\u003c\/td\u003e\n\u003ctd\u003e121\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-1-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-1-0-awg-3-conductors\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1836\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-1-0-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-2-0-awg-3-conductors%20\"\u003e2\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2034\u003c\/td\u003e\n\u003ctd\u003e166\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-2-0-awg-3-conductors%20\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-3-0-awg-3-conductors\"\u003e3\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2428\u003c\/td\u003e\n\u003ctd\u003e189\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-3-0-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-4-0-awg-3-conductors\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3092\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-4-0-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-250-mcm-3-conductors\"\u003e250 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4290\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-250-mcm-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-350-mcm-3-conductors\"\u003e350 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4550\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-350-mcm-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-500-mcm-3-conductors\"\u003e500 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e8270\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-500-mcm-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130052657215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg.jpg?v=1571726340"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-1-awg-3-conductors","title":"1 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\/0.007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\/0.178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.915 x 0.630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48.6 x 16.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1829\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130052689983,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_989b78e3-4a73-4ec0-9992-bca407ea78c0.jpg?v=1571726340"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-1-0-awg-3-conductors","title":"1\/0 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\/0.007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\/0.178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.170 x 0.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55.1 x 16.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1836\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130052722751,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_6b0d9f3f-5756-41c2-bf64-a0c1ee7632a5.jpg?v=1571726340"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-10-awg-2-conductors","title":"10 AWG 2 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.013\/0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.330\/0.102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.60 x 0.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 x 6.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130052886591,"sku":"","price":1.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_7e9aa290-bc2f-4fdb-8fed-51f03f398498.jpg?v=1571726340"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-10-awg-3-conductors","title":"10 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.013\/0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.330\/0.102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 x 0.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 x 6.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130052919359,"sku":"","price":2.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_563ee45a-88a4-4058-9e47-a8fad72af209.jpg?v=1571726340"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-12-awg-2-conductors","title":"12 AWG 2 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.037\/0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.939\/0.102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.56 x 0.23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.2 x 5.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054000703,"sku":"","price":1.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_6ee84ebe-c483-4f99-ad35-fc17d5b2d409.jpg?v=1571726340"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-12-awg-3-conductors","title":"12 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" border=\"1\" bordercolor=\"#D0D8E5\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.013\/0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.330\/0.102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.59 x 0.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.9 x 5.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054164543,"sku":"","price":1.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_4e56ab80-7453-4555-9def-04649491adbe.jpg?v=1571726340"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-14-awg-2-conductors","title":"14 AWG 2 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.013\/0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.330\/0.102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.54 x 0.22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.7 x 5.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054197311,"sku":"","price":1.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_94032abf-7156-48ac-aa5a-339711f4120a.jpg?v=1571726340"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-14-awg-3-conductors","title":"14 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.013\/0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.330\/0.102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.54 x 0.22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.7 x 5.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054230079,"sku":"","price":1.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_355e3463-0560-44dd-a71c-20d86bfd1224.jpg?v=1571726340"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-2-awg-3-conductors","title":"2 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.036\/0.006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.914\/0.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.72 x 0.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.6 x 12.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054262847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_d89abbb0-ad9c-4e49-a309-48645add934d.jpg?v=1571726341"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-2-0-awg-3-conductors","title":"2\/0 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\/0.007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\/0.178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.360 x 0.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59.9 x 17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e166\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054295615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_fd66d609-9a29-4b1e-98be-f69c958139b6.jpg?v=1571726341"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-250-mcm-3-conductors","title":"250 MCM 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.054\/0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.372\/0.203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.150 x 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80.0 x 25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054328383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_7ab5b072-8af7-43f4-aef0-f2844f55b5c3.jpg?v=1571726341"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-3-0-awg-3-conductors","title":"3\/0 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\/0.007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\/0.178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.580 x 0.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65.5 x 18.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2428\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e189\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054361151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_80031d26-2867-47c3-9538-6d27966b60aa.jpg?v=1571726341"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-350-mcm-3-conductors","title":"350 MCM 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.054\/0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.372\/0.203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.550 x 1.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.1 x 30.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054393919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_21cb140e-d04d-4431-baf2-2953fbb161cb.jpg?v=1571726341"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-4-awg-3-conductors","title":"4 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" border=\"1\" bordercolor=\"#D0D8E5\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.036\/0.006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.914\/0.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.47 x 0.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.3 x 11.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e721\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054426687,"sku":"","price":5.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_6651e2aa-43bc-4d93-8504-3df3f124b826.jpg?v=1571726341"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-4-0-awg-3-conductors","title":"4\/0 AWG 3 Conductors Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\/0.007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\/0.178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.820 x 0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e71.6 x 20.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054852671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_c9852e67-e194-417f-a431-29434b982ea5.jpg?v=1571726341"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-500-mcm-3-conductors","title":"500 MCM 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts offers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.  Electrical pump situations \u003ca name=\"_GoBack\"\u003e\u003c\/a\u003ecan be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.  Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCSA Standard 22.2 No. 49 \u003c\/strong\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.054\/0.008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.372\/0.203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.860 x 1.065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.0 x 27.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054885439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_b4b82724-ff9d-4951-b992-c2f71f67d0fe.jpg?v=1571726341"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-6-awg-3-conductors","title":"6 AWG 3 Conductor Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.027\/0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.686\/0.127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.18 x 0.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.9 x 10.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e487\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054918207,"sku":"","price":4.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_67f49c4c-e0d3-4716-983b-16d219ab6105.jpg?v=1571726341"},{"product_id":"flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts-8-awg-3-conductors","title":"8 AWG 3 Conductors Flat Submersible Pump Cable w\/Ground 600V","description":"\u003cmeta charset=\"utf-8\"\u003eFLAT SUBMERSIBLE PUMP CABLE 2 \u0026amp; 3 CONDUCTOR W\/ GROUND 600 VOLTS - 8 AWG - 3 Conductors\u003cmeta name=\"Description\" content=\"This multiconductor cable features a flattened design to maximize crush and impact resistance.  The cable comes with the option of two or three conductors.  Class C soft drawn bare copper phase conductors make up the cables conductive components\"\u003e\u003cmeta name=\"Keywords\" content=\"Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor w\/grnd 600V - 8 AWG - 3 Conductors,Pump Cable,Submersible Pump Cable, Insulated Cable,Jacketed Cable,Flat Submersible Pump Cable,PVC Insulation Cable,W\/GRND 600V Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eFlat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Voltsoffers excellent durability and its construction is designed to withstand heavy impact. The link is ordinarily utilized as a part of pump applications in private, business, and mechanical zones or any area with high measures of water and dampness. It is frequently used to in swimming pools, wellsprings, and sprinkler frameworks. The link is intended to work in wet conditions, notwithstanding when it is totally submerged in water. Its PVC coat and aluminum interlocked defensive layer shield the link from concealed submerged risks that may harm the conductors. The link holds a greatest temperature rating of 90°C in both wet and dry areas. Different utilizations for the Armored Submersible Round Cable incorporate direct entombment and installed in cement.Electrical pump situations can be hazardous. There is dependably a danger of electrical shock when you blend power with water. Here at Nassau Electrical Supply, we know the significance of having dependable and safe submersible pump link and we expect to supply you with the best gear available so you can rest guaranteed that your submersible pump won't turn into an electrical risk.Flat Submersible Pump Cable 2 \u0026amp; 3 Conductor W\/ Ground 600 Volts has a multi-conductor design that allows you to connect 2-3 circuits at once.  This comes in handy in a flood situation so you don’t have to fish around for multiple cords underwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eUL Spec. No. 493\u003c\/strong\u003e - These prerequisites spread 14 - 4\/0 AWG single-conductor PVC-protected and - jacketed underground feeder and branch-circuit link and level numerous conductor PVC-jacketed underground feeder and branch-circuit links containing a few 14 - 6 AWG PVC-protected circuit conductors with or without an establishing conductor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eCSA Standard 22.2 No. 49 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003e- This standard specifies the requirements for flexible cords, elevator cables, electric vehicle cables, and hoistway cables rated 600 V maximum and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN\/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada, NOM-001-SEDE, La Norma de InstalacionesElectricas (Mexican Electrical Code [MEC]), in Mexico, and NFPA 70, National Electrical Code (NEC), in the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times, serif;\"\u003eJacket: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: times, serif;\"\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"611\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 510px;\"\u003e\u003cstrong\u003eNUMBER OF INSULATED CONDUCTORS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 85px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGROUNDING CONDUCTOR SIZE AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.027\/0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eINSULATION THICKNESS AVERAGE\/MINIMUM PVC\/NYLON (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.686\/0.127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJACKET THICKNESS (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (IN.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99 x 0.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE O.D. (MM.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.6 x 8.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE WEIGHT (LB\/MFT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAMPACITY (1) 40 DEGREES AMBIENT TEMP.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7130054950975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7271-SP-lg_ee4581dc-facd-4f00-86d8-ef7940e260de.jpg?v=1571726341"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/flat-submersible-pump-cable-2-3-conductor-w-ground-600-volts.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}