{"title":"Draka Cable TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant Cable for Instrumentation and Telecommunication Overall Screened Pairs\/Triples","description":"","products":[{"product_id":"draka-cable-2-cores-10-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856634","title":"Draka Cable 2 Cores 10 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856634","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 10 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856634\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 10 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856634. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856634, 2 Cores 10 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856634, 856634, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e17.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e22 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e570\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e201\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856634\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129758367807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-10-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856834","title":"Draka Cable 2 Cores 10 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856834","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 10 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856834\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 10 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856834. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856834, 2 Cores 10 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856834, 856834, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e22.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e27 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e850\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e342\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856834\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129758433343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_0de168b7-dda9-49c2-a593-5216707834a5.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-10-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856633","title":"Draka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856633","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856633\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856633. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856633, 2 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856633, 856633, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e17.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e22 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e570\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e201\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856633\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129758531647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_05f2c64e-a110-4ace-886a-542b86f61f8e.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-10-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856833","title":"Draka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856833","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856833\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856833. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856833, 2 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856833, 856833, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e22.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e27 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e850\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e342\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856833\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129758564415,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_b4caf0f0-5ef1-4e66-80fe-a19cf4b1d4a3.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-16-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856643","title":"Draka Cable 2 Cores 16 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856643","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 16 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856643\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 16 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856643. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856643, 2 Cores 16 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856643, 856643, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e20 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e24.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e760\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e285\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856643\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129759350847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_f2b3423f-7c46-4834-b969-f59ef08f7aca.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-16-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856843","title":"Draka Cable 2 Cores 16 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856843","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 16 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856843\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 16 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856843. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856843, 2 Cores 16 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856843, 856843, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e25.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e30.5 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e509\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856843\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129760661567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_5bf8cc7e-13ad-4ac2-9106-03ebe4b5fadf.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-16-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856642","title":"Draka Cable 2 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856642","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856642\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856642. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856642, 2 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856642, 856642, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e20 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e24.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e760\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e285\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856642\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129760956479,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_2eb1b26d-a944-43b9-86b9-3df5994844ad.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-16-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856842","title":"Draka Cable 2 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856842","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856842\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856842. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856842, 2 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856842, 856842, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e25.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e30.5 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e509\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856842\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129760989247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_e7fa977b-d192-403c-936c-ed108ff8294c.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-2-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856607","title":"Draka Cable 2 Cores 2 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856607","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 2 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856607\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 2 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856607. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856607, 2 Cores 2 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856607, 856607, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e10 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e14 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e230\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e63\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856607\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129761120319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_e3bf7eea-cc35-450b-b398-a570a7d08f85.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-2-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856807","title":"Draka Cable 2 Cores 2 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856807","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 2 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856807\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 2 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856807. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856807, 2 Cores 2 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856807, 856807, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e12.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e16.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e310\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856807\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129762168895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_ac638aa3-b1c5-4f5f-a2ac-375d4cef0e62.jpg?v=1571726229"},{"product_id":"draka-cable-2-cores-2-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856606","title":"Draka Cable 2 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856606","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856606\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856606. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856606, 2 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856606, 856606, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e10 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e14 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e230\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e63\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856606\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129762267199,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_8d9d91dd-e6e7-41eb-9ec4-b6e8541e8a17.jpg?v=1571726230"},{"product_id":"draka-cable-2-cores-2-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856806","title":"Draka Cable 2 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856806","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856806\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856806. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856806, 2 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856806, 856806, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e12.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e16.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e310\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856806\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129762562111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_1ad1bab6-ee99-47be-962e-e83214952d04.jpg?v=1571726230"},{"product_id":"draka-cable-2-cores-24-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856649","title":"Draka Cable 2 Cores 24 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856649","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 24 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856649\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 24 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856649. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856649, 2 Cores 24 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856649, 856649, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e24.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e29.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1070\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e397\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856649\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129762725951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_719f106a-ebc7-4b88-bdf3-9c7f0df1b274.jpg?v=1571726230"},{"product_id":"draka-cable-2-cores-24-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856849","title":"Draka Cable 2 Cores 24 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856849","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 24 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856849\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 24 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856849. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856849, 2 Cores 24 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856849, 856849, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e32 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e38 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1930\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e909\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856849\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129762791487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_19003e3f-2814-4120-8482-da045aebbb62.jpg?v=1571726230"},{"product_id":"draka-cable-2-cores-24-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856648","title":"Draka Cable 2 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856648","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856648\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856648. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856648, 2 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856648, 856648, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e24.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e29.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1070\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e397\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856648\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129762824255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_ec58a558-b2b3-41c3-ace3-b8ddb4ba4fc9.jpg?v=1571726230"},{"product_id":"draka-cable-2-cores-24-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856848","title":"Draka Cable 2 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856848","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856848\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856848. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856848, 2 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856848, 856848, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e32 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e38 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1930\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e909\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856848\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129764560959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_f5894623-038b-4d7f-a216-b9f62ceba0dc.jpg?v=1571726230"},{"product_id":"draka-cable-2-cores-4-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856619","title":"Draka Cable 2 Cores 4 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856619","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 4 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856619\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 4 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856619. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856619, 2 Cores 4 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856619, 856619, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e11.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e16 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e295\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e91\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856619\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129765478463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_0dfc35a5-5fb4-45dc-8ba5-37033b83aba4.jpg?v=1571726230"},{"product_id":"draka-cable-2-cores-4-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856819","title":"Draka Cable 2 Cores 4 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856819","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 4 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856819\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 4 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856819. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856819, 2 Cores 4 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856819, 856819, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e14.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e19 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e430\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e156\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856819\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129765904447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_cba00348-b09a-497a-bbf9-e7235c28b70e.jpg?v=1571726230"},{"product_id":"draka-cable-2-cores-4-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856618","title":"Draka Cable 2 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856618","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856618\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856618. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856618, 2 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856618, 856618, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e11.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e16 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e295\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e91\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856618\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129767280703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_f0062eb5-6e87-45e5-a48e-9ebd9b709570.jpg?v=1571726230"},{"product_id":"draka-cable-2-cores-4-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856818","title":"Draka Cable 2 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856818","description":"\n    \n        \u003ctitle\u003eDraka Cable 2 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856818\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 2 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856818. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856818, 2 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856818, 856818, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e14.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e19 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e430\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e156\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856818\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129767313471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_6d30a261-9637-4fff-8a98-9dcd2a5c39e3.jpg?v=1571726230"},{"product_id":"draka-cable-3-cores-10-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856694","title":"Draka Cable 3 Cores 10 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856694","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 10 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856694\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 10 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856694. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856694, 3 Cores 10 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856694, 856694, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e20 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e24.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e750\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e271\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856694\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129770491967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_dacf4b60-1ec8-405b-93fe-f2c3872a8800.jpg?v=1571726231"},{"product_id":"draka-cable-3-cores-10-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856894","title":"Draka Cable 3 Cores 10 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856894","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 10 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856894\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 10 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856894. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856894, 3 Cores 10 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856894, 856894, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples, Umbilicals Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e25.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e30.5 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1140\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e482\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856894\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129770557503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_2e756bbd-1dae-4b07-b045-baec9c9762d7.jpg?v=1571726231"},{"product_id":"draka-cable-3-cores-10-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856693","title":"Draka Cable 3 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856693","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856693\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856693. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856693, 3 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856693, 856693, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e20 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e24.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e750\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e271\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856693\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129770623039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_e85d114a-10f0-44ee-8310-f63d908508b0.jpg?v=1571726231"},{"product_id":"draka-cable-3-cores-10-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856893","title":"Draka Cable 3 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856893","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856893\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856893. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856893, 3 Cores 10 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856893, 856893, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples, Umbilicals Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e25.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e30.5 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1140\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e482\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856893\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129770688575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_df12818c-9188-4079-b64e-56285fabcf47.jpg?v=1571726231"},{"product_id":"draka-cable-3-cores-16-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856703","title":"Draka Cable 3 Cores 16 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856703","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 16 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856703\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 16 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856703. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856703, 3 Cores 16 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856703, 856703, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e22.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e27.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e990\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e397\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856703\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129770819647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_dc9d39da-1bc8-4243-b1e3-d12eed0d5eff.jpg?v=1571726231"},{"product_id":"draka-cable-3-cores-16-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856903","title":"Draka Cable 3 Cores 16 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856903","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 16 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856903\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 16 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856903. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856903, 3 Cores 16 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856903, 856903, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples, Umbilicals Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e29 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e35 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1740\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e910\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856903\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129771999295,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_1c2caeb0-657f-467e-a2d2-96a32c69665c.jpg?v=1571726231"},{"product_id":"draka-cable-3-cores-16-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856702","title":"Draka Cable 3 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856702","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856702\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856702. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856702, 3 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856702, 856702, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e22.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e27.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e990\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e397\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856702\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129772064831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_11774825-1d83-4c7b-b413-611f5e57e2ac.jpg?v=1571726231"},{"product_id":"draka-cable-3-cores-16-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856902","title":"Draka Cable 3 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856902","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856902\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856902. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856902, 3 Cores 16 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856902, 856902, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples, Umbilicals Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e29 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e35 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1740\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e910\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856902\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129772130367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-sm.jpg?v=1571726231"},{"product_id":"draka-cable-3-cores-2-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856667","title":"Draka Cable 3 Cores 2 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856667","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 2 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856667\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 2 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856667. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856667, 3 Cores 2 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856667, 856667, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e11.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e15.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e270\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e77\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856667\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129772752959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_8609cdf3-022e-4e3f-929d-c958a0846211.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-2-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856867","title":"Draka Cable 3 Cores 2 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856867","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 2 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856867\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 2 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856867. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856867, 3 Cores 2 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856867, 856867, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e14 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e18.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e390\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e129\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856867\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129773178943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_a16fc214-c37a-47a2-ac26-16e22f6a83c3.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-2-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856666","title":"Draka Cable 3 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856666","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856666\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856666. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856666, 3 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856666, 856666, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e11.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e15.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e270\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e77\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856666\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129773277247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_211d123f-b679-40e0-aeb5-01c2be50c189.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-2-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856866","title":"Draka Cable 3 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856866","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856866\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856866. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856866, 3 Cores 2 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856866, 856866, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e14 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e18.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e390\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e129\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856866\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129773310015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_3f0c1885-b4e5-4af7-af9f-d15e8c7c2d5c.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-24-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856709","title":"Draka Cable 3 Cores 24 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856709","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 24 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856709\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 24 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856709. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856709, 3 Cores 24 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856709, 856709, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e27.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.02\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e34 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1490\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e662\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856709\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129774030911,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_a6ad3047-f638-4aa6-9496-40c406159d39.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-24-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856909","title":"Draka Cable 3 Cores 24 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856909","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 24 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856909\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 24 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856909. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856909, 3 Cores 24 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856909, 856909, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples, Umbilicals Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e36 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e42.5 ± 2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2490\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1245\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856909\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129774161983,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_8e85b1dd-98bf-4120-beda-3935ce54346b.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-24-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856708","title":"Draka Cable 3 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856708","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856708\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856708. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856708, 3 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856708, 856708, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e27.5 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.02\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e34 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1490\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e662\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856708\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129774194751,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_ae20b757-4417-4b59-8240-6e4b341e43d5.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-24-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856908","title":"Draka Cable 3 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856908","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856908\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856908. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856908, 3 Cores 24 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856908, 856908, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples, Umbilicals Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e36 ± 1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e42.5 ± 2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2490\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1245\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856908\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129774227519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_cf94300d-d723-4cdc-bd74-01d4b4957594.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-4-elements-0-75-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856679","title":"Draka Cable 3 Cores 4 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856679","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 4 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856679\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 4 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856679. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856679, 3 Cores 4 Elements 0.75 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856679, 856679, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e13 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e17.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e370\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e127\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856679\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129774358591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_dbcb0e62-eb73-444d-9542-0c0f0193e763.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-4-elements-1-5-cross-section-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856879","title":"Draka Cable 3 Cores 4 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856879","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 4 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856879\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 4 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856879. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856879, 3 Cores 4 Elements 1.5 Cross-section TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856879, 856879, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples, Umbilicals Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e16.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e21 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e540\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e212\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856879\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129774587967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_670103f6-e379-44e0-b3e2-7450b6398a95.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-4-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856678","title":"Draka Cable 3 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856678","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856678\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856678. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856678, 3 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856678, 856678, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e13 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e17.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e370\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e127\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856678\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129774948415,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_91359c84-f328-49df-b893-61b3da20fe6c.jpg?v=1571726232"},{"product_id":"draka-cable-3-cores-4-elements-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cable-856878","title":"Draka Cable 3 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856878","description":"\n    \n        \u003ctitle\u003eDraka Cable 3 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856878\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Draka Cable 3 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856878. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Draka Cable Price, Draka Cable Quote, Draka Cable 856878, 3 Cores 4 Elements TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant and Instrumentation Cable 856878, 856878, TFSI Cable, XLPE Insulation Cable, Flame Retardant Cable, Instrumentation Cable, Telecommunication Cable, Overall Screened Cable, Wire Accessories Cable, Annealed Stranded Copper Conductor Cable, HFXLPE Insulation Cable, Halogen free Cable, TFSI(c) 250V XLPE\/LSTPE\/PO Flame Retardant Cable for Instrumentation and Telelecommunication Overall Screened Pairs\/Triples\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Annealed stranded circular copper, IEC 60228 class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad Twisting\u003c\/strong\u003e: Color coded cores twisted together and wrapped with polyester tape. Pairs\/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs\/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Concentric copper conductor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant halogen-free thermoplastic compound, SHF1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"meter\" \"ar\" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification Instrumentation Cables\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-Light Blue\u003cbr\u003e\n        • Triple - Black-Light Blue-Brown\u003cbr\u003e\n        • Quad - Black-Light Blue-Brown-Grey\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • IEC 60092-376 - Design\u003cbr\u003e\n        • IEC 60228 class 2 - Conductor\u003cbr\u003e\n        • IEC 60092-351 - Insulation\u003cbr\u003e\n        • IEC 60092-359 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 0.75mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24PAIR 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 2TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 4TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 10TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 16TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003cbr\u003e\n        • TFSI(C) 24TRIP 1.5mm2 S105\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter bedding, mm\u003c\/td\u003e\n                    \u003ctd\u003e16.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ewire diameter concentric conductor, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e21 ± 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e540\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e212\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003edraka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e856878\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7129775472703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TFSI_c_20250V_20XLPE_20Cable-lg_f9bc448d-a49f-44b3-856f-f4b6b252656e.jpg?v=1571726232"},{"product_id":"draka-cable-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-cable-for-instrumentation-and-telecommunication-overall-screened-pairs-triples","title":"Draka Cable TFSI(c) 250V XLPE\/LSTPE\/CWS\/PO Flame Retardant Cable for Instrumentation and Telecommunication Overall Screened Pairs\/Triples","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eIts made of annealed stranded, circular copper conductor and a cross linked polyethylene insulator on top of the conductor. The color coded cores are twisted together and wrapped with a polyester tape. It has an inner covering made of a thermoplastic compound which is designed to be flame retardant and halogen free. A concentric copper conductor is put in place as the cables armor and an additional outer sheath which is also made from a thermoplastic compound to its ability to resist flames. It has marking texts on the outer sheath to give information on the manufacturer and its specifications. Its operating temperature is at 90 degrees Celsius and its power rating is at 250 volts.\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cstrong\u003eRange and Dimensions\u003c\/strong\u003e \u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of \u003cbr\u003e cores in element\u003c\/td\u003e\n\u003ctd\u003enumber of \u003cbr\u003e elements\u003c\/td\u003e\n\u003ctd\u003ecopper content \u003cbr\u003e approx. (kg\/km)\u003c\/td\u003e\n\u003ctd\u003edraka cable \u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003ctd\u003e856606\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-2-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003ctd\u003e856607\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-2-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003ctd\u003e856618\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-4-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003ctd\u003e856619\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-4-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e201\u003c\/td\u003e\n\u003ctd\u003e856633\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-10-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e201\u003c\/td\u003e\n\u003ctd\u003e856634\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-10-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003ctd\u003e856642\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-16-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003ctd\u003e856643\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-16-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e397\u003c\/td\u003e\n\u003ctd\u003e856648\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-24-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e397\u003c\/td\u003e\n\u003ctd\u003e856649\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-24-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003ctd\u003e856666\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-2-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003ctd\u003e856667\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-2-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e127\u003c\/td\u003e\n\u003ctd\u003e856678\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-4-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e127\u003c\/td\u003e\n\u003ctd\u003e856679\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-4-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e271\u003c\/td\u003e\n\u003ctd\u003e856693\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-10-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e271\u003c\/td\u003e\n\u003ctd\u003e856694\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-10-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e397\u003c\/td\u003e\n\u003ctd\u003e856702\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-16-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e397\u003c\/td\u003e\n\u003ctd\u003e856703\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-16-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e662\u003c\/td\u003e\n\u003ctd\u003e856708\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-24-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e662\u003c\/td\u003e\n\u003ctd\u003e856709\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-24-elements-0-75-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003ctd\u003e856806\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-2-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-c-1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003ctd\u003e856807\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-2-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-i\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e156\u003c\/td\u003e\n\u003ctd\u003e856818\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-4-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-c-1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e156\u003c\/td\u003e\n\u003ctd\u003e856819\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-4-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-i\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003ctd\u003e856833\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-10-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation--1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003ctd\u003e856834\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-10-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e509\u003c\/td\u003e\n\u003ctd\u003e856842\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-16-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation--1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e509\u003c\/td\u003e\n\u003ctd\u003e856843\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-16-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e909\u003c\/td\u003e\n\u003ctd\u003e856848\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-24-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation--1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e909\u003c\/td\u003e\n\u003ctd\u003e856849\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-2-cores-24-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003ctd\u003e856866\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-2-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-c-1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003ctd\u003e856867\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-2-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-i\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003ctd\u003e856878\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-4-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation-c-1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003ctd\u003e856879\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-4-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-i\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e482\u003c\/td\u003e\n\u003ctd\u003e856893\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-10-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation--1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e482\u003c\/td\u003e\n\u003ctd\u003e856894\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-10-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e910\u003c\/td\u003e\n\u003ctd\u003e856902\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-16-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation--1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e910\u003c\/td\u003e\n\u003ctd\u003e856903\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-16-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003ctd\u003e856908\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-24-elements-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-instrumentation--1\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003ctd\u003e856909\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/wire-accessories\/umbilicals\/draka-cable-3-cores-24-elements-1-5-cross-section-tfsi-c-250v-xlpe-lstpe-cws-po-flame-retardant-and-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Draka Cable","offers":[{"title":"Default Title","offer_id":7375599960127,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/tsf.jpg?v=1571729403"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/tsf.jpg?v=1523973828","url":"https:\/\/www.nassauelectrical.com\/collections\/draka-cable-tfsic-250v-xlpe-lstpe-cws-po-flame-retardant-cable-for-instrumentation-and-telecommunication-overall-screened-pairs-triples.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}