{"title":"Belden 18 AWG Pairs Overall Beldfoil Shielding Exposed Run Green Insulated Ground Wire UL Instrumentation 600V Tray Cable","description":"","products":[{"product_id":"belden-18-awg-pairs-overall-beldfoil-shielding-exposed-run-green-insulated-ground-wire-ul-instrumentation-600v-tray-cable","title":"Belden 18 AWG Pairs Overall Beldfoil Shielding Exposed Run Green Insulated Ground Wire UL Instrumentation 600V Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eReliability – even in the harshest of environments – is the hallmark of Belden instrumentation cables.\u003c\/p\u003e\n\u003cp\u003eNo matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e: \u003cbr\u003e • Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit \u003cbr\u003e • Superior electrical performance and longer runs in dozens of different environments \u003cbr\u003e • Assured, flexible installation connections with all the necessary ratings\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e: \u003cbr\u003e • Jacket options for excellent resistance to oil, outdoor sunlight\/UV, flame and extreme temperatures \u003cbr\u003e • Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity \u003cbr\u003e • Conductor options to provide increased flexibilty, greater flex life and corrosion resistance\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround Wire\u003c\/strong\u003e: \u003cbr\u003e • Ground Wire (Y\/N): Y \u003cbr\u003e • Ground Wire AWG: 18 \u003cbr\u003e • Ground Wire Stranding: 7x26 \u003cbr\u003e • Ground Wire Conductor Material: BC - Bare Copper \u003cbr\u003e • Ground Wire Insulation Material: PVC\/Nylon - Polyvinyl Chloride\/Nylon\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: \u003cbr\u003e • Material: PVC\/Nylon - Polyvinyl Chloride\/Nylon\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e: \u003cbr\u003e • AWG: 20 \u003cbr\u003e • Stranding: 7x28 \u003cbr\u003e • Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e: \u003cbr\u003e • Material: PVC - Polyvinyl Chloride \u003cbr\u003e • Nom. Wall Thickness (mm): 1.2192 \u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Charactertistics (Overall)\u003c\/strong\u003e: \u003cbr\u003e • Wet Temperature Range: -30°C To +75°C \u003cbr\u003e • Dry Temperature Range: -30°C To +90°C \u003cbr\u003e • Bulk Cable Weight: 56 lbs\/1000 ft. \u003cbr\u003e • Max. Recommended Pulling Tension: 80 lbs. \u003cbr\u003e • Min. Bend Radius\/Minor Axis: 3.400 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e: \u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e: \u003cbr\u003e • NEC\/(UL) Specification: NPLF, TC-ER, UL 1277 \u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes \u003cbr\u003e • EU CE Mark: Yes \u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes \u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes \u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 09\/23\/2005 \u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes \u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes \u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes \u003cbr\u003e • MII Order #39 (China RoHS): Yes \u003cbr\u003e • Other Specification: ICEA S-73-532, S-61-402\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e: \u003cbr\u003e • Nom. Inductance (?H\/ft): 0.1945 \u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 74.3 \u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 41.3 \u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86 \u003cbr\u003e • Nominal Outer Shield DC Resistance @ 20°C (Ohm\/1000 ft): 7.46 \u003cbr\u003e • Max. Operating Voltage - UL: 600 V RMS (NEC Type TC) \u003cbr\u003e • Max. Operating Voltage - UL: 150 V RMS (NPLF)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e: \u003cbr\u003e • UL Flame Test: UL1685 UL Loading \u003cbr\u003e • C(UL) Flame Test: FT4 \u003cbr\u003e • IEEE Flame Test: 1202 \u003cbr\u003e • ICEA Flame Test: T-29-520\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e: \u003cbr\u003e • Suitability - Burial: Yes \u003cbr\u003e • Sunlight Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e: \u003cbr\u003e • Plenum (Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003eoverall cable- \u003cbr\u003e nominal \u003cbr\u003e dia. (mm)\u003c\/td\u003e\n\u003ctd\u003ebelden cable \u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e8.636\u003c\/td\u003e\n\u003ctd\u003e3088AE\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/belden-cables\/industrial-wire\/instrumentation-cable\/belden-3088ae-18-awg-1-pair-600v-multi-conductor-pvc-nylon-insulation-tray-cable\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e8.636\u003c\/td\u003e\n\u003ctd\u003e3088CE\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/belden-cables\/industrial-wire\/instrumentation-cable\/belden-3088ce-18-awg-1-pair-600v-multi-conductor-xlpe-insulation-tray-cable\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161742032959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/18_20awg_20Pair_20TC_20Overall_20Ground_20Wire-lg.jpg?v=1571727871"},{"product_id":"belden-3088ae-18-awg-1-pair-7x26-stranding-bare-copper-600v-instrumentation-tray-cable","title":"Belden 3088AE 18 AWG 1 Pair 7x26 Stranding Bare Copper 600V Instrumentation Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\n\u003cstrong\u003eBelden 3088AE 18 AWG 1 Pair 7x26 Stranding Bare Copper 600V Instrumentation Tray Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e18 AWG pairs stranded (7x26) bare copper conductors, twisted pairs, PVC\/Nylon insulation, overall Beldfoil shield (100% coverage), insulated green ground wire, PVC jacket.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PVC\/Nylon - Polyvinyl Chloride + Nylon\u003cbr\u003e• Nom. Thickness: 0.022 in (0.56 mm)\u003cbr\u003e• Nom. Insulation Diameter: 0.088 in (2.2 mm)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Drainwire Type: 20 AWG (7x28) TC - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Jacket:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Thickness: 0.048 in\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eVoltage Rating: 600 V (TC), 150 V (NPLF)\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature: -30°C to +90°C Dry, -30°C To +75°C wet\u003cbr\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eApplications:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e•\u003c\/strong\u003e Instrumentation Applications in Plants, TC-ER, Exposed Run Applications\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eSpecifications:\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eElement: Pair(s)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSize (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• No. of Pair\u003c\/span\u003e: \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eStranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• Conductor \u003c\/span\u003eMaterial: \u003c\/strong\u003eBC - Bare Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eElement: Ground\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSize (AWG): \u003c\/strong\u003e18\u003cstrong\u003e\u003cbr\u003e\u003cspan\u003e• No. of Element\u003c\/span\u003e: \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eStranding: \u003c\/strong\u003e7x26\u003cstrong\u003e\u003cbr\u003e\u003cspan\u003e• Conductor \u003c\/span\u003eMaterial: \u003c\/strong\u003eBC - Bare Copper\u003cstrong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003ePart Number:\u003c\/strong\u003e 3088AE\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3088AE_1.pdf?v=1768970436\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7162518470719,"sku":"NES3088AE","price":1.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled.png74_eb40e2b5-0908-4bf3-9a46-453b91966873.png?v=1768970799"},{"product_id":"belden-3088ce-18-awg-1-pair-600v-multi-conductor-xlpe-insulation-tray-cable","title":"Belden 3088CE 18 AWG 1 Pair 600V Multi Conductor XLPE Insulation Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: \u003cbr\u003e • 18 AWG pairs stranded (7x26) bare copper conductors, twisted pairs, PVC\/Nylon insulation, overall Beldfoil shield (100% coverage), insulated green ground wire, PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround Wire\u003c\/strong\u003e: \u003cbr\u003e • Ground Wire (Y\/N): Y \u003cbr\u003e • Ground Wire AWG: 18 \u003cbr\u003e • Ground Wire Stranding: 7x26 \u003cbr\u003e • Ground Wire Conductor Material: BC - Bare Copper \u003cbr\u003e • Ground Wire Insulation Material: XLPE - Cross Linked Polyethylene\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: \u003cbr\u003e • Material: XLPE - Cross Linked Polyethylene\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e: \u003cbr\u003e • AWG: 20 \u003cbr\u003e • Stranding: 7x28 \u003cbr\u003e • Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e: \u003cbr\u003e • Material: PVC - Polyvinyl Chloride \u003cbr\u003e • Nom. Wall Thickness (mm): 1.2192 \u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUsage (Overall)\u003c\/strong\u003e: \u003cbr\u003e\u003cstrong\u003eSuitable Applications\u003c\/strong\u003e: \u003cbr\u003e • Instrumentation Applications in Plants, TC-ER, Exposed Run Applications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Charactertistics (Overall)\u003c\/strong\u003e: \u003cbr\u003e • Wet Temperature Range: -30°C To +75°C \u003cbr\u003e • Dry Temperature Range: -30°C To +90°C \u003cbr\u003e • Bulk Cable Weight: 61 lbs\/1000 ft. \u003cbr\u003e • Max. Recommended Pulling Tension: 80 lbs. \u003cbr\u003e • Min. Bend Radius\/Minor Axis: 3.400 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e: \u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e: \u003cbr\u003e • NEC\/(UL) Specification: TC-ER, UL 1277 \u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes \u003cbr\u003e • EU CE Mark: Yes \u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes \u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes \u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 08\/01\/2005 \u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes \u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes \u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes \u003cbr\u003e • MII Order #39 (China RoHS): Yes \u003cbr\u003e • Other Specification: ICEA S-73-532, S-66-524\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e: \u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 54 \u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 30 \u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86 \u003cbr\u003e • Nominal Outer Shield DC Resistance @ 20°C (Ohm\/1000 ft): 7.46 \u003cbr\u003e • Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e: \u003cbr\u003e • UL Flame Test: UL1685 UL Loading \u003cbr\u003e • C(UL) Flame Test: FT4 \u003cbr\u003e • IEEE Flame Test: 1202\/383 \u003cbr\u003e • ICEA Flame Test: T-29-520\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e: \u003cbr\u003e • Suitability - Burial: Yes \u003cbr\u003e • Sunlight Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e: \u003cbr\u003e • Plenum (Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# paris\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003ebare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einner shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einner shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable- nominal dia. (mm)\u003c\/td\u003e\n\u003ctd\u003e8.636\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e3088CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7162518503487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/18_20awg_20Pair_20TC_20Overall_20Ground_20Wire-lg_f2edec78-3c26-41de-92b5-0ce2d26e976b.jpg?v=1571728011"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/belden-18-awg-pairs-overall-beldfoil-shielding-exposed-run-green-insulated-ground-wire-ul-instrumentation-600v-tray-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}