{"title":"ASD-VFD Tray Cable Shielded","description":"","products":[{"product_id":"1-0-3-vfdtc-tray-cable","title":"1\/0-3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.188\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,672\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e1\/0-3 ASD-VFD Tray Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1\/0-3 ASD-VFD tray cable is a standard cable used in ASD \/ VFD applications. These cables are designed according to the following regulations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Standard 1277\u003c\/li\u003e\n\u003cli\u003eICEA T-29-520\u003c\/li\u003e\n\u003cli\u003eIEEE 383\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 \/ CSA FT-4\u003c\/li\u003e\n\u003cli\u003eNational Electrical Code regulations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese cables are approved for direct burial and use in a number of hazardous locations. They are also RoHS compliant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2.\u003c\/li\u003e\n\u003cli\u003eFor use in ASD \/ VFD applications.\u003c\/li\u003e\n\u003cli\u003eStandards: UL 1277\u003c\/li\u003e\n\u003cli\u003eFlame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1\/0 and larger IEEE 1202 \/ CSA FT-4 Two-hour Firewall rated, (2\/0 AWG and smaller)Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eJacketCode: Black and Numbered\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: 90?C Wet \/ Dry ICEA S-95-658 \/ NEMA WC-70\u003c\/li\u003e\n\u003cli\u003eExposed runs rated #4 and larger 600 Volt Tray Cable RoHS Compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1\/0-3 ASD-VFD tray cables feature six conductors: three standard, live conductors and three symmetrical bare copper ground wires. The three main conductors have a size of 1\/0 AWG and a stranding of 19 At\/Stl. The ground wires are 6 AWG. The conductors are covered with a durable cross-linked polyethylene insulation that’s protects the wire from moisture and heat. This insulation has a nominal thickness of 55 mm. All six of the conductors are cabled together and covered with a 5-mil helical copper tape shield. The entire cable is then covered with a PVC jacket to provide additional protection from fire and sunlight. This complete cable has an overall diameter of 1.188 inches.\u003c\/p\u003e\n\u003cp\u003eThis particular cable has an allowable ampacity of 170 amps at an operating temperature of 30 degrees C. It’s rated for a maximum voltage of 600 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese types of ASD-VFD cables are designed to work with variable frequency drives (VFD) and AC motors. The cable connects the two so that the VFD can adjust the speed of the AC motor and change the torque. By verifying the voltage and the motor input frequency, the VFD is able to conserve power and can improve the performance of the motor. These types of motors are often used in fans, conveyors, and water pumps.\u003c\/p\u003e\n\u003cp\u003e1\/0-3 ASD-VFD cables are rated for use in NEC Hazardous Location, including Class I, Division 2, Class II, Division 2, and Class III, Divisions 1 and 2 areas. They can be used in wet or dry areas as needed.\u003c\/p\u003e\n\u003cp\u003eVariable frequency drive cables are used by many to put together variable frequency drive system to a motor. The cables are majorly used in so many big factories and other automated service system in companies. This makes it very necessary to consider putting in mind the kind of machines used; they really must have high end technological cables to be able to carry out work such as grinding, data processing and even bottling. Because the machines are quite heavy, this is why we need standard VFD cables.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/wire-and-cable-resources\/articles\/standard-variable-frequency-drive-cable\"\u003eRead More\u003c\/a\u003e\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160173822015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable.jpg?v=1571727575"},{"product_id":"1-3-vfdtc-tray-cable","title":"1\/3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160179949631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_c8e36b51-081c-408c-93a7-6f618f6d96a3.jpg?v=1571727576"},{"product_id":"10-3-vfdtc-tray-cable","title":"10\/3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e343\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160199151679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_e6ccfeda-1180-4fea-8c9a-7876064d790b.jpg?v=1571727593"},{"product_id":"12-3-vfdtc-tray-cable","title":"12\/3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e273\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160237686847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_ea701e82-e9c3-4ef4-a745-3f0480573505.jpg?v=1571727598"},{"product_id":"14-3-vfdtc-tray-cable","title":"14\/3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e239\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160260460607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_bfe2b789-7f18-4b7c-a2b1-f218c4d9f5e8.jpg?v=1571727603"},{"product_id":"2-0-3-vfdtc-tray-cable","title":"2\/0-3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,984\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e2\/0-3 ASD-VFD Tray Cables\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2\/0-3 ASD-VFD tray cables are primarily used with variable frequency drives (VFD) and motors. They are designed according to the National Electrical Code and meet a number of different standards for fire and sunlight resistance. These codes include IEEE 383 and IEEE 1202 \/ CSA FT-4; ICEA T-29-520; and UL 1277. This cable is rated for direct burial use and is RoHS compliant. It is also designed to be used in hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2.\u003c\/li\u003e\n\u003cli\u003eFor use in ASD \/ VFD applications.\u003c\/li\u003e\n\u003cli\u003eStandards: UL 1277\u003c\/li\u003e\n\u003cli\u003eFlame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1\/0 and larger IEEE 1202 \/ CSA FT-4 Two-hour Firewall rated, (2\/0 AWG and smaller)Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eJacketCode: Black and Numbered\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: 90?C Wet \/ Dry ICEA S-95-658 \/ NEMA WC-70\u003c\/li\u003e\n\u003cli\u003eExposed runs rated #4 and larger 600 Volt Tray Cable RoHS Compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2\/0-3 ASD-VFD cable makes use of three stranded conductors. The stranding is 19 Al\/Stl, while the size of the conductors is 2\/0 AWG. The conductors are insulated using a cross-linked polyethylene insulation with a nominal thickness of 55 mm. They are then cabled together with three symmetrical bare copper ground conductors that have a size of 6 AWG. The overall diameter of the entire cable is 1.289 inches. The cable is then covered with a PVC jacket that is resistant to direct sunlight and flames.\u003c\/p\u003e\n\u003cp\u003eThe cable’s allowable ampacity is 195 amps at 30 degrees C. It has a maximum voltage of 600 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll ASD-VFD cables are designed to conned VFDs with AC motors. These adjustable speed drives are found in a number of different pieces of equipment. The cable helps to adjust the speed of the motor and the torque. By varying the voltage and motor input speed periodically, the motor’s performance is improved and less power is used. ASD-VFD cables are often seen in fan motors, conveyor motors, and water pumps.\u003c\/p\u003e\n\u003cp\u003eThese cables can be used in both wet and dry areas. The standard operating temperature of the conductors, however, should never exceed 90 degrees C. The cable may also be used in NEC Hazardous Locations labeled as Class I, Div 2, Class II, Div 2, and Class III, Div 1 and Div 2.\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160351129663,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_f4073048-0c8b-4fcc-a49d-014a926840d8.jpg?v=1571727644"},{"product_id":"2-3-vfdtc-tray-cable","title":"2\/3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.998\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e2\/3 ASD-VFD Tray Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOne cable that may be used in different ASD \/ VFD motors is the 2\/3 ASD-VFD tray cable. These tray cables are rated to withstand flames and other environmental hazards. These cables comply with the following regulations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll required National Electrical Code guidelines\u003c\/li\u003e\n\u003cli\u003eUL Standard 1277\u003c\/li\u003e\n\u003cli\u003eIEEE 383\u003c\/li\u003e\n\u003cli\u003eICEA T-29-520\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 \/ CSA FT-4\u003c\/li\u003e\n\u003cli\u003eAll applicable RoHS regulations (cables are RoHS compliant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2.\u003c\/li\u003e\n\u003cli\u003eFor use in ASD \/ VFD applications.\u003c\/li\u003e\n\u003cli\u003eStandards: UL 1277\u003c\/li\u003e\n\u003cli\u003eFlame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1\/0 and larger IEEE 1202 \/ CSA FT-4 Two-hour Firewall rated, (2\/0 AWG and smaller)Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eJacketCode: Black and Numbered\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: 90?C Wet \/ Dry ICEA S-95-658 \/ NEMA WC-70\u003c\/li\u003e\n\u003cli\u003eExposed runs rated #4 and larger 600 Volt Tray Cable RoHS Compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese cables make use of three conductors. In the 2\/3 cable, these conductors have a stranding of 7 Al\/Stl and a size of 2 AWG. They are secured with a cross-linked polyethylene that protects them from damage from heat and moisture. The conductors are then bundled with three symmetrical bare copper grounds and covered with a 5-mil helical copper tape shield. Then the entire cable is jacketed with a sunlight and fire resistant 80 mils thick jacket. Overall, the complete cable has a diameter of .998 inches.\u003c\/p\u003e\n\u003cp\u003eThe total allowable ampacity of this cable is 130 amps at 30 degrees C. It has been rated for 600 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2\/3 ASD-VFD tray cables are designed to work with variable frequency drives (VFD) and AC motors. They are used in a number of different types of electro-mechanical drive systems in order to adjust the speed of the drive and the torque. The VFD does this by changing the motor input frequency and the amount of voltage being send through the 2\/3 ASD-VFD cable. By changing the speed, the performance of the motor is improved, plus it uses less power overall.\u003c\/p\u003e\n\u003cp\u003eThese types of motors are found in a number of different pieces of equipment, including water pumps, conveyors, and fan motors. They may be found in indoor or outdoor locations and can be used in dry and wet environments. They are rated for use in NEC Hazardous Locations, including Class I, Div 2, Class II, Div 2, and Class III, Div 1 and 2. Regardless of where it’s used, the conductor operating temperature should not exceed 90 degrees.\u003c\/p\u003e\n\u003cp\u003eWhen buying a cable, you just do not need to go for anything on the shelves. What you need is quality and affordable cable. One that will be able to give you value for your money at all times. Therefore just as mentioned a standard VFD cable is all you need.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/wire-and-cable-resources\/articles\/standard-vfd-cables\"\u003eRead More\u003c\/a\u003e\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160356732991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_3f54e62e-e026-403e-b1c2-400d48757f78.jpg?v=1571727645"},{"product_id":"250-3-vfdtc-tray-cable","title":"250-3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160412766271,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_9b12a09a-d22f-427d-86c6-9d34625224b0.jpg?v=1571727670"},{"product_id":"3-0-3-vfdtc-tray-cable","title":"3\/0-3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.390\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e3\/0-3 ASD-VFD Tray Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3\/0-3 ASD-VFD tray cable is used in a number of different ASD\/VFD environments, mostly as a control cable for motors. All ASD-VFD cables must meet a specific number of guidelines and requirements, including everything specified in the National Electrical Code. In addition to meeting the NEC guidelines, these cables are also flame rated and meet the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Standard 1277\u003c\/li\u003e\n\u003cli\u003eIEEE 383 and 1202 \/ CSA FT-4\u003c\/li\u003e\n\u003cli\u003eICEA T-29-520\u003c\/li\u003e\n\u003cli\u003eThey are RoHS complaint.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2.\u003c\/li\u003e\n\u003cli\u003eFor use in ASD \/ VFD applications.\u003c\/li\u003e\n\u003cli\u003eStandards: UL 1277\u003c\/li\u003e\n\u003cli\u003eFlame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1\/0 and larger IEEE 1202 \/ CSA FT-4 Two-hour Firewall rated, (2\/0 AWG and smaller)Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eJacketCode: Black and Numbered\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: 90?C Wet \/ Dry ICEA S-95-658 \/ NEMA WC-70\u003c\/li\u003e\n\u003cli\u003eExposed runs rated #4 and larger 600 Volt Tray Cable RoHS Compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA 3\/0-3 ASD-VFD tray cable features three conductors and three symmetrical bare copper ground conductors. The live conductors are stranded (19 Al\/Stl) and have a size of 3\/0 AWG. They are protected by a cross-linked polyethylene insulation that resists heat and moisture. The insulation is phase identified and has a nominal thickness of 55 mm. Both conductors are then cabled together and protected via a 5-mil helical copper tape shield. The shield is then covered by a PVC jacket with a thickness of 80 mils. This jacket is resistant to flame and sunlight, giving the wire even more protection. The cable’s overall complete diameter is 1.390 inches.\u003c\/p\u003e\n\u003cp\u003e3\/0-3 ASD-VFD wire has an allowable ampacity of 225 amps at 30 degrees C. It’s rated for 600 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA 3\/0-3 cable is often used to connect AC motors to variable frequency drives. These types of drives are used in many different electro-mechanical systems to change the torque and the speed of the motor. By varying the motor input frequency and the voltage, the speed changes, which can actually provide better performance and even help conserve power. These cables are often found in fans, conveyors, water pumps, and more.\u003c\/p\u003e\n\u003cp\u003eThe 3\/0-3 ASD-VFD cable may be used in a variety of environments (both wet and dry) where the operating temperature will not climb above 90 degrees C. This include a number of NEC Hazard Locations.\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160429543487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_b6062359-e287-4ff8-92a7-561ae7d7365f.jpg?v=1571727672"},{"product_id":"3-3-vfdtc-tray-cable","title":"3\/3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e896\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160434491455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_7d46b53f-0ec7-4fd3-bbce-ddd77055a3dd.jpg?v=1571727673"},{"product_id":"350-3-vfdtc-tray-cable","title":"350-3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.983\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,898\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e350-3 ASD-VFD Tray Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 350-3 ASD-VFD tray cable is designed for use in ASD \/VFD applications. These cables meet UL Standard 1277 and are flame rated according to a number of different regulations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 383\u003c\/li\u003e\n\u003cli\u003eICEA T-29-520\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 \/ CSA FT-4\u003c\/li\u003e\n\u003cli\u003eThese cables are also rated for CT use and for direct burial.\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese cables meet all applicable guidelines of the National Electrical Code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2.\u003c\/li\u003e\n\u003cli\u003eFor use in ASD \/ VFD applications.\u003c\/li\u003e\n\u003cli\u003eStandards: UL 1277\u003c\/li\u003e\n\u003cli\u003eFlame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1\/0 and larger IEEE 1202 \/ CSA FT-4 Two-hour Firewall rated, (2\/0 AWG and smaller)Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eJacketCode: Black and Numbered\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: 90?C Wet \/ Dry ICEA S-95-658 \/ NEMA WC-70\u003c\/li\u003e\n\u003cli\u003eExposed runs rated #4 and larger 600 Volt Tray Cable RoHS Compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 350-3 cable features three stranded conductors with a size of 350 AWG. It has a stranding (Al\/Stl) of 37. This cable also features 3 symmetrical bare copper ground wires that are 2 AWG in size. The cable core is covered with a special 5-mil helical copper tape shield. This is in addition to the cross-linked polyethylene insulation. This insulation has a nominal thickness of 65 mm and is moisture and heat resistant. A black PVC jacket provides an outer layer of protection and is resistant to flame, sunlight, and abrasions. While black is standard, other colors can be substituted for easy identification.\u003c\/p\u003e\n\u003cp\u003eThe overall cable diameter for this cable is 1.983 inches. This cable has an allowable ampacity of 350 amps at 30 degrees C and weighs 4,898 pounds in lengths of 1,000 feet. It is rated for 600 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD cables such as the 350-3 cable are used in a number of different applications involving motors. They connect Variable Frequency Drives (VFDs) to AC motors. A VFD is an adjustable-speed drive that’s used in a number of different electro-mechanical drive systems to control the speed of the AC motor and the torque. It varies the voltage and the motor input frequency. Doing so helps conserve power and improve performance. These cables can be used with motors that control water pumps, fan motors, conveyor motors, and more.\u003c\/p\u003e\n\u003cp\u003eThese cables can be used in a number of places designated as NEC Hazardous Locations, including those designed as Class I, Division 2, Class II, Division 2, and Class III, Divisions I and II. It may be used in wet or dry areas where the operating temperature does not exceed 90 degrees C.\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160436097087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_70a126f4-88a4-4112-8ec3-078e923ce14a.jpg?v=1571727674"},{"product_id":"4-0-3-vfdtc-tray-cable","title":"4\/0-3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,982\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e4\/0-3 ASD-VFD Tray Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor those who need cables to use in ASD \/ VFD applications, the 4\/0-3 tray cable may be a good fit. This cable is manufactured according to all of the guidelines listed in the National Electrical Code. This includes IEEE 383 and IEEE 1202\/CSA FT-4. It also includes UL Standard 1277, ICEA T29-520, and is flame rated. It is also rated for CT use and may be directly buried for underground use. This cable is also RoHS compliant. It has been designated by the NEC as useful in all hazardous locations that have been designated as Class I, Division 2, Class II, Division 2, or Class III, Divisions I and II.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2.\u003c\/li\u003e\n\u003cli\u003eFor use in ASD \/ VFD applications.\u003c\/li\u003e\n\u003cli\u003eStandards: UL 1277\u003c\/li\u003e\n\u003cli\u003eFlame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1\/0 and larger IEEE 1202 \/ CSA FT-4 Two-hour Firewall rated, (2\/0 AWG and smaller)Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eJacketCode: Black and Numbered\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: 90?C Wet \/ Dry ICEA S-95-658 \/ NEMA WC-70\u003c\/li\u003e\n\u003cli\u003eExposed runs rated #4 and larger 600 Volt Tray Cable RoHS Compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 4\/0-3 ASD-VFD tray cable has three conductors and three symmetrical bare copper ground wires. The conductors are stranded with a stranding of 19 Al\/Stl and are cabled together with the grounds. This core is then covered with a 5-mil helical copper tape shield. The conductors are also insulated with a cross-linked polyethylene insulation that is highly resistant to moisture and heat. The nominal thickness of this insulation is 55 mm, and the entire assembly is then covered in a sunlight and flame-resistant PVC jacket that is 80 mils thick. The jacket can be surface printed and is available in a variety of colors or basic black.\u003c\/p\u003e\n\u003cp\u003eThis cable’s allowable ampacity is 260 amps at 30 degrees C. It is rated for 600 volts. A spool of 1,000 feet of this cable is 2,982 pounds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese cables are used to connect a variable frequency drive (a VFD) to an AC motor. This allows the speed to be adjusted as necessary by changing the voltage and the motor input frequency. By doing this, the motor will actually use less power and perform better. ASD-VFD cables can be used in many different motors, including those found in conveyor belts, fans, and water pumps.\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160452186175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_2142ffe2-ecb2-4376-ac93-f66fc54c4669.jpg?v=1571727677"},{"product_id":"4-3-vfdtc-tray-cable","title":"4\/3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.869\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e766\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e4\/3 ASD-VFD Tray Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e4\/3 ASD-VFD tray cable is a special cable designed for use in equipment that includes a variable frequency drive that is connected to an AC motor. These cables are manufactured according to a number of different guidelines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Standard 1277\u003c\/li\u003e\n\u003cli\u003eIEEE 383\u003c\/li\u003e\n\u003cli\u003eICEA T-29-520\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 \/ CSA FT-4\u003c\/li\u003e\n\u003cli\u003eAll applicable National Electrical Codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese cables are also rated for CT use and for direct burial and are RoHS compliant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2.\u003c\/li\u003e\n\u003cli\u003eFor use in ASD \/ VFD applications.\u003c\/li\u003e\n\u003cli\u003eStandards: UL 1277\u003c\/li\u003e\n\u003cli\u003eFlame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1\/0 and larger IEEE 1202 \/ CSA FT-4 Two-hour Firewall rated, (2\/0 AWG and smaller)Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eJacketCode: Black and Numbered\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: 90?C Wet \/ Dry ICEA S-95-658 \/ NEMA WC-70\u003c\/li\u003e\n\u003cli\u003eExposed runs rated #4 and larger 600 Volt Tray Cable RoHS Compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll 4\/3 ASD-VFD cables feature three conductors and three symmetrical bare copper ground wires. The live conductors are covered with cross-linked polyethylene insulation that is phase identified. It has a nominal thickness of 45 mm. All conductors, both live and ground, are bundled together along with fillers and then covered with a protective copper tape shield. This shield is then covered with a 80 mils thick jacket that provides extra protection from flames and from direct sunlight. The jacket comes in a standard black, but other colors can be requested to make identification easier.\u003c\/p\u003e\n\u003cp\u003eThe maximum voltage for this cable is 600 volts. Its allowable ampacity is 95 amps at 30 degrees C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 4\/3 ASD-VFD tray cable is primarily used in electro-mechanical drive systems to connect an AC motor to a variable frequency drive (VFD). By changing the voltage periodically and adjusting the motor input frequency, these drives are able to adjust the speed of the motor and the torque. This conserves power and also improves the overall performance of the motor. Such motors are often found in water pumps, conveyor motors, fan motors, and more.\u003c\/p\u003e\n\u003cp\u003eAll ASD-VFD cables can be buried and used in wet and dry environments as long as the conductor’s operating temperature doesn’t exceed 90 degrees C. They may be used in the following NEC Hazardous Locations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Division 2\u003c\/li\u003e\n\u003cli\u003eClass II, Division 2\u003c\/li\u003e\n\u003cli\u003eClass III, Division 1\u003c\/li\u003e\n\u003cli\u003eClass III, Division 2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160457396287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_a53bf217-7067-49ff-8260-b7f089cc94cb.jpg?v=1571727678"},{"product_id":"500-3-vfdtc-tray-cable","title":"500-3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.271\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,677\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e500-3 ASD-VFD Tray Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOne of the cables most often used with variable frequency drives (VFDs) is a ASD-VFD tray cable. The 500-3 option of this cable is manufactured to meet a number of different regulations and the guidelines of the National Electrical Code. These guidelines include UL Standard 1277, IEEE 383, IEEE 1202 \/ CSA FT-4, and ICEA T-29-520. They are also rated for use underground, including direct burial, and are RoHS compliant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2.\u003c\/li\u003e\n\u003cli\u003eFor use in ASD \/ VFD applications.\u003c\/li\u003e\n\u003cli\u003eStandards: UL 1277\u003c\/li\u003e\n\u003cli\u003eFlame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1\/0 and larger IEEE 1202 \/ CSA FT-4 Two-hour Firewall rated, (2\/0 AWG and smaller)Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eJacketCode: Black and Numbered\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: 90?C Wet \/ Dry ICEA S-95-658 \/ NEMA WC-70\u003c\/li\u003e\n\u003cli\u003eExposed runs rated #4 and larger 600 Volt Tray Cable RoHS Compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis type of cable makes use of stranded conductors that have a stranding (Al\/Stl) of 37. The cable features three conductors and three bare copper ground wires. The conductors have a size of 500 AWG, while the grounds have a size of 1 AWG. These wires and conductors are all protected by a cross-linked polyethylene insulation that has a nominal thickness of 65 mm. This insulation is heat and moisture resistance. The core of the cable is also protected by a special 5-mil helical copper tape shield. On top of all of this, there’s a sunlight resistant and flame resistant PVC jacket over everything. This jacket comes in a variety of colors (black is standard) and has a thickness of 110 mils.\u003c\/p\u003e\n\u003cp\u003eThe overall cable diameter is 2.271 inches, and its overall allowable ampacity is 430 amps. It’s rated for 600 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 500-3 ASD-VFD cable is designed for use as a connecting cable for variable frequency drives and AC motors. These cables control the speed and the torque of the motor by varying the motor input frequency and the voltage. This reduces the amount of power needed and also helps improve the overall performance. There are a number of different electro-mechanical drive systems such as fan motors, water pumps, and conveyor belt motors.\u003c\/p\u003e\n\u003cp\u003eThese cables can be used in the following locations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWet and dry environments\u003c\/li\u003e\n\u003cli\u003eLocations where the standard operating temperature of the conductors will not be above 90 degrees C\u003c\/li\u003e\n\u003cli\u003eNEC Hazardous Locations designated Class I, Div. 2; Class II, Div. 2; and Class III, Div. and Div. 2.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160483250239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_5b8cc68e-8c6f-4240-9557-856ad49252bc.jpg?v=1571727700"},{"product_id":"6-3-vfdtc-tray-cable","title":"6\/3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.725\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e544\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/wire-and-cable-resources\/articles\/vfd-cable\"\u003eRead More\u003c\/a\u003e\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160498159679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_e035c019-c308-4aa1-8118-763fa6c7214f.jpg?v=1571727703"},{"product_id":"600-3-vfdtc-tray-cable","title":"600-3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160532041791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_a7e0637d-8b06-48af-bcce-69e5ad62d47c.jpg?v=1571727709"},{"product_id":"750-3-vfdtc-tray-cable","title":"750-3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,062\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160537514047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_b4ef6248-02a1-4843-ba24-b5e96d373cab.jpg?v=1571727710"},{"product_id":"8-3-vfdtc-tray-cable","title":"8\/3 VFDTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts.  The annealed copper used in this cable offers superior flexibility compared to standard copper.  Annealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.  The copper conductors are insulated in heat and moisture resistant crosslinked polyethylene.  The cable also includes three symmetrical bare copper ground conductors.  The ground conductors serve to ensure steady conductivity through the phase conductors.  The assembly of conductors is fitted with suitable fillers to avoid shifting, and then covered with a shield of 5-mil helical copper tape.  The cable bears a black polyvinyl chloride outer jacket that is resistant to flame, sunlight, ozone, moisture, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eASD-VFD Tray Cable is designed for use in Adjustable Speed Drive (sometimes referred to as Variable Speed Drive or Variable Frequency Drive) applications.  ASD’s are most commonly used to drive AC motor speed and torque in industrial applications using varying voltages and frequencies.  Their purpose is to adjust current as needed to reduce excess voltages that drive up energy costs.  This cable passes IEEE 70,000 BTU flame test as well as the ICEA T-29-520 210,000 BTU flame test.  The cable’s heat and flame tolerance makes the cable suitable for installation in locations with an increased risk of fire.  The cable is designed for installation in cable tray and is most often found in factories, plants, and refineries. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable aligns with UL standard 1277, a specification that sets standards for the performance of multi-conductor cables.\u003c\/li\u003e\n\u003cli\u003eThe cable adheres to the regulations specified in ICEA S-95-658\/NEMA WC-70.  This article sets standards for cross-linked polyethylene insulated cables.\u003c\/li\u003e\n\u003cli\u003eFor exposed runs, this cable is rated TC-ER for #4 AWG and larger.\u003c\/li\u003e\n\u003cli\u003eThe cable is compliant with Restriction of Hazardous Substances directive.\u003c\/li\u003e\n\u003cli\u003eThe ASD-VFD Tray Cable Shielded passes IEEE 383 70,000 BTU flame test, ICEA T-29-520 210,000 BTU, and IEEE 1202\/CSA FT-4 Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ASD-VFD Shielded Tray Cable is a triple-conductor cable that features three soft annealed copper phase conductors to transmit ampacities of up to 600 volts. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper used in this cable offers superior flexibility compared to standard copper.\u003c\/li\u003e\n\u003cli\u003eAnnealed copper undergoes a process in which it is heated and slowly cooled, removing interior stress from the copper to make the cable tougher, but more malleable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in heat and moisture resistant crosslinked polyethylene. \u003c\/li\u003e\n\u003cli\u003eThe cable’s conductors are rated XHHW-2.\u003c\/li\u003e\n\u003cli\u003eThe insulation is high heat and water-resistant.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable includes three symmetrical bare copper ground conductors.\u003c\/li\u003e\n\u003cli\u003eThe ground conductors serve to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes suitable fillers to ensure the conductors fit snugly within the jacket and will not shift under stress.\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s core is covered with 5-mil helical copper tape.\u003c\/li\u003e\n\u003cli\u003eThe cable shield’s purpose is to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s exterior jacket is made of polyvinyl chloride (PVC).\u003c\/li\u003e\n\u003cli\u003eThe PVC jacket protects the cable from flame, moisture, sunlight, and chemicals.\u003c\/li\u003e\n\u003cli\u003eThe cable’s standard jacket is black, but colors are available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.644\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 30C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7161386598463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_291f372b-9f1d-4c63-87e0-751c02300146.jpg?v=1571727711"},{"product_id":"asd-vfd-tray-cable-shielded","title":"ASD-VFD Tray Cable Shielded","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003eThe ASD-VFD shielded tray cable is insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. The stranded cable core is covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.\u003cbr\u003e Wiring shielded cables will protect from electro-static interference, avoiding signal interference and providing low resistance. A shielded tray cable offers reliable performance and the flexibility for a variety of installations. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2.\u003c\/li\u003e\n\u003cli\u003eFor use in ASD \/ VFD applications.\u003c\/li\u003e\n\u003cli\u003eStandards: UL 1277\u003c\/li\u003e\n\u003cli\u003eFlame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1\/0 and larger IEEE 1202 \/ CSA FT-4 Two-hour Firewall rated, (2\/0 AWG and smaller)Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eJacketCode: Black and Numbered\u003c\/li\u003e\n\u003cli\u003eTemperature Rating: 90€C Wet \/ Dry ICEA S-95-658 \/ NEMA WC-70\u003c\/li\u003e\n\u003cli\u003eExposed runs rated #4 and larger 600 Volt Tray Cable RoHS Compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA good cable is what all of us are looking for when carrying out an installation process. You need a \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/tray-cable\"\u003etray cable\u003c\/a\u003e that offers durability, flexibility, and one that can be used in medium voltage frequencies is the best option. My advice is you need an MMV-VFD cable and you will have an easier time on installations.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/wire-and-cable-resources\/articles\/mmv-vfd-cable\"\u003eRead More\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eIn most cases, wiring can be a tricky affair. This is because of the bending, high temperatures, stretching and other resistance that come with cables. To avoid any hiccups during cable installation, you need a flexible TC-ER VFD cable. View the informative \u003ca href=\"http:\/\/www.houwire.com\/pdf\/AmerCable_VFD_Specifications.pdf\"\u003ePDF from HouWire\u003c\/a\u003e to get a clear outline of these cables. However, if you just want to get an overview of what a flexible TC-ER VFD cable entails, here is a summary.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/wire-and-cable-resources\/articles\/flexible-tc-er-vfd-cable\"\u003eRead More\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electrical Code has various specifications on the kind of cable to be used during installations. One of the cables that strictly meets these regulations is the CIR VFD Cable (crush resistant and impact resistant VFD cable). This cable is so good that it can be used in zone 2, division 2 and even in class 1 environments without any hitches since most of it is a 2kv power cable. It is also flexible and can also be used in AC motor drives regardless of the variable frequencies that comes with it.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/wire-and-cable-resources\/articles\/cir-vfd-cable-crush-resistant-and-impact-resistant-vfd-cable\"\u003eRead More\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eTake a look at our product table below, and whether you need a shielded or unshielded tray wire cable, we’ll provide you with an instant quote for the amount of cable you need. Our customer service and commitment to providing you with the cables you require will make for a smooth transaction at an affordable price. \u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize AWG\/kcmil\u003c\/td\u003e\n\u003ctd\u003eno of conductors in cable\u003c\/td\u003e\n\u003ctd\u003eWeight Per 1000ft Total (Lbs.)\u003c\/td\u003e\n\u003ctd\u003eAllowable Ampacity 30C (Amps)\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/14-3-vfdtc-tray-cable\"\u003e14\/3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e239\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/14-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/12-3-vfdtc-tray-cable\"\u003e12\/3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e273\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/12-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/10-3-vfdtc-tray-cable\"\u003e10\/3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e343\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/10-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/8-3-vfdtc-tray-cable\"\u003e8\/3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/8-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/6-3-vfdtc-tray-cable\"\u003e6\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e544\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/6-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/4-3-vfdtc-tray-cable\"\u003e4\/3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e766\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/4-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/3-3-vfdtc-tray-cable\"\u003e3\/3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e896\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/3-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/2-3-vfdtc-tray-cable\"\u003e2\/3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1,111\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/2-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/1-3-vfdtc-tray-cable\"\u003e1\/3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1,339\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/1-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/1-0-3-vfdtc-tray-cable\"\u003e1\/0-3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1,672\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/1-0-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/2-0-3-vfdtc-tray-cable\"\u003e2\/0-3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1,984\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/2-0-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/3-0-3-vfdtc-tray-cable\"\u003e3\/0-3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2,501\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/3-0-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/4-0-3-vfdtc-tray-cable\"\u003e4\/0-3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2,982\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/4-0-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/250-3-vfdtc-tray-cable\"\u003e250-3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3,581\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/250-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/350-3-vfdtc-tray-cable\"\u003e350-3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4,898\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/350-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/500-3-vfdtc-tray-cable\"\u003e500-3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e6,677\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/500-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/600-3-vfdtc-tray-cable\"\u003e600-3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e8,049\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/600-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tray-cable\/750-3-vfdtc-tray-cable\"\u003e750-3 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e10,062\u003c\/td\u003e\n\u003ctd\u003e535\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/tray-cable\/750-3-vfdtc-tray-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7161654476863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-tray-cable-1.jpg?v=1571727837"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/lg-tray-cable-1_470x_fc3bc85e-fd3b-4d99-bff3-e97118e21f01.jpg?v=1524283050","url":"https:\/\/www.nassauelectrical.com\/collections\/asd-vfd-tray-cable-shielded.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}