General Cable Polyrad® Ultra Wire 12 AWG 600V Single Conductor 125C Reduced Weight Smaller Diameter Dual Wall

General Cable Polyrad® Ultra Wire 12 AWG 600V Single Conductor 125C Reduced Weight Smaller Diameter Dual Wall

Polyrad Ultra Wire 12 AWG 600V Single Conductor 125C Reduced Weight Smaller Diameter Dual Wall

Conductor: 22 AWG thru 10 AWG soft annealed tinned copper per ASTM B33, B8 and B172

Dual Insulation:
• Polyrad® ULTRA flame-retardant, low-smoke irradiated Cross-linked Polyolefin (XLPO)
• Cross-linked fluoropolymer

Options:
• Available in multi-conductor constructions
• Available in colors other than dark gray

Applications:
• Ideally suited for use where high-density cabling is required, as this wire offers both size and weight advantages
• Engineered and manufactured for both original equipment and retrofit use in electronics equipment
• Utilized where environmental factors require wire characteristics to perform with a high degree of flame retardancy and excellent moisture-stable electrical values. Where reliability is the major concern and where maximum performance will be demanded
• For use on all types of heavy- and light-rail cars, rapid transit cars and diesel-electric locomotives

Features:
• Reduced diameter and lighter-weight transit wire — up to 33% smaller in diameter and lighter in weight than conventional Polyrad® XT 600 V
• Temperature rating at 125ºC for long life, higher ampacities and protection from thermal overloads
• Outstanding thermal stability at elevated temperatures
• Maximum flame retardance
• Excellent low-temperature performance; suitable for installation in sub-zero conditions
• Extra-tough, mechanically rugged irradiated thermoset insulation
• Resistant to most oils and chemicals
• Meets cold bend test at –55ºC

Compliances:
Industry:
• ICEA S-95-658
• RoHS Compliant

Flame Test:
• IEEE 1202 (70,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• VW-1

Other:
• BSS 7239
• SMP 800-C
• ASTM E662
• NFPA 130 STD 2010
• ASTM 1354

Packaging: Standard reel put-up

technical specifications:
conductor size(awg) 12
conductor stranding 19/25
nominal conductor diameter(inches) 0.086
nominal conductor diameter(mm) 2.18
nominal insulation thickness(mils) 10
nominal insulation thickness(mm) 0.254
nominal jacket thickness(mils) 5
nominal jacket thickness(mm) 0.127
copper weight(lbs./1000') 19
copper weight(kg/km) 28
nominal cable diameter(inches) 0.116
nominal cable diameter(mm) 2.95
net cable weight(lbs./1000') 23
net cable weight(kg/km) 34
ampacity (free air 40?c ambient) 125?c 55
catalog number 369600

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question