Popular Products

  • Amercable Tiger Brand Type SHD-GC 3/C TPU Jacket 5/8/15/25kV Mining Cable

    Select gauge from drop-down menu for prices:


    Free Shipping

    No End Date

    Click to View Shopping Cart

    Conductors: Flexible tinned copper 

    Ground Check Conductor2: Flexible tinned copper with yellow polypropylene insulation 

    Strand Shield: Semi-conducting layer

    Insulation: 90°C ethylene-propylene rubber (EPR) 

    Ground Wires: Flexible tinned copper 

    Tape: Non-conducting 

    Insulation Shielding: Tinned copper and color coded nylon braid 

    Assembly: Taped core 

    Jacket1: Thermoplastic Polyurethane (TPU) Jacket. Cable identification via permanent marking. 

    Application: 
    • Heavy duty portable power cable for use in circuits not exceeding 5,000 volts. Designed for applications such as shovels, dredges and drills. Recommended maximum continuous conductor temperature in 90°C. Suitable for shallow water submersion. 
    • Heavy duty high voltage portable power cable for use in circuits not exceeding the rated voltage. These cables are used for heavy mobile equipment such as drag lines, shovels, dredges, and for power feeders.Recommended maximum continuous conductor temperature in 90°C. Suitable for shallow water submersion.(8kv,15kv,25kv)
    • Cable carries “P-184-MSHA” marking indicating acceptance as flame resistant by the Pennsylvania Department of Environmental Protection and the Mine Safety and Health Administration. 
    • Tiger® Brand Mining Cable meets or exceeds ICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33. 

    Ratings & Approvals: 
    • Mine Safety & Health Administration 184-MSHA. 
    • Pennsylvania Department of Environmental Protection P-184. 
    • Insulated Cable Engineers Association S-75-381/NEMA WC-58. Design standard for mining cables. 
    • Canadian Standards Association C22.2 No. 96 File 82346, FT1, FT5, -50°C CSA Phase Color ID available on Type SHD-GC, SHD-BGC up to 25kV 
    • Canadian Standards Association C22.2 No. 96 File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTO Type SHD-GC, SHD-BGC up to 25kV SHD-GC meets FT4 requirements(8kv,15kv,25kv)

    power conductors grounding conductors jacket
    thickness
    mils
    nominal
    outside
    dimensions
    in.
    approx.
    weight lbs.
    per1,000 ft.
    ampacity *
    40°c
    ambient
    temp
    amercable and
    tiger brand
    part number
    size
    awg
    no. of wires
    per 
    conductor
    insulation
    thickness
    mils
    size
    awg
    no. of wires
    per conductor
    36-514 type shd-gc 3/c tpu jacket 5000 volts
    6 133 110 10 49 185 1.56 1342 93 36-514-006
    4 259 110 8 133 185 1.68 1629 122 36-514-004
    2 259 110 6 133 205 1.87 2228 159 36-514-002
    1 259 110 5 133 205 1.95 2447 184 36-514-001
    1/0 266 110 4 259 220 2.08 2760 211 36-514-010
    2/0 323 110 3 259 220 2.20 3238 243 36-514-020
    3/0 418 110 2 259 235 2.36 3792 279 36-514-030
    4/0 532 110 1 259 235 2.50 4548 321 36-514-040
    250 627 120 1/0 266 250 2.69 5427 355 36-514-250
    350 888 120 2/0 323 265 2.95 7070 435 36-514-350
    500 1221 120 4/0 532 280 3.31 9407 536 36-514-500
    36-518 type shd-gc tpu jacket 8000 volts
    4 259 150 8 133 205 1.94 2019 122 36-518-004
    2 259 150 6 133 220 2.12 2603 159 36-518-002
    1 259 150 5 133 220 2.21 2913 184 36-518-001
    1/0 266 150 4 259 220 2.32 3351 211 36-518-010
    2/0 323 150 3 259 235 2.46 3946 243 36-518-020
    3/0 418 150 2 259 250 2.62 4582 279 36-518-030
    4/0 532 150 1 259 250 2.75 5321 321 36-518-040
    250 627 150 1/0 266 250 2.89 6101 355 36-518-250
    350 888 150 2/0 323 280 3.20 7696 435 36-518-350
    500 1221 150 4/0 532 295 3.56 10199 536 36-518-500
    36-521 type shd-gc 3/c tpu jacket 15000 volts
    2 259 210 6 133 235 2.41 3145 164 36-521-002
    1 259 210 5 133 235 2.52 3567 187 36-521-001
    1/0 266 210 4 259 250 2.64 3976 215 36-521-010
    2/0 323 210 3 259 255 2.73 4526 246 36-521-020
    3/0 418 210 2 259 265 2.90 5231 283 36-521-030
    4/0 532 210 1 259 265 3.05 6033 325 36-521-040
    250 627 210 1/0 266 265 3.15 6602 359 36-521-250
    350 888 210 2/0 323 280 3.40 8306 437 36-521-350
    500 1221 210 4/0 532 280 3.68 10497 534 36-521-500
    36-526 type shd-gc 3/c tpu jacket 25000 volts
    1 259 260 5 133 265 2.95 4410 191 36-526-001
    1/0 266 260 4 259 265 3.05 4866 218 36-526-010
    2/0 323 260 3 259 280 3.20 5560 249 36-526-020
    3/0 418 260 2 259 280 3.33 6192 286 36-526-030
    4/0 532 260 1 259 295 3.50 7110 327 36-526-040
    250 627 260 1/0 266 295 3.54 7692 360 36-526-250
    350 888 260 2/0 323 295 3.85 9608 439 36-526-350

    Quick Quote Form 

    * Indicates required field

    Receive A Response In 5 Minutes Or Less During Regular Business Hours

    Captcha Image