General Cable Anaconda® Brand Type SHD-BGC 1 Gauge Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 2000 Volts Three Conductor

General Cable Anaconda® Brand Type SHD-BGC 1 Gauge Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 2000 Volts Three Conductor

Product Details

Conductor: 1 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172

Insulation: Ethylene Propylene Rubber (EPR) insulation 

Insulation Shield: A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape

Ground-Check Conductor:
• Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex fatigue 
• Insulated with high-strength polypropylene and placed in the center interstice

Grounding Conductors: Three coated copper, rope-lay-stranded per ASTM B172 in contact with the flexible braid shield

Jacket: Reinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE) 

Jacket Marking: GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE SHD-BGC 2000 VOLTS (-50C) FT1 FT5 CSA LR 27161 P-7K-102-045 MSHA

Options: 
• Colored jackets are available 
• TPU (Thermoplastic Polyurethane) jacket 
• Anamaxx® jacket 

Applications: 
• Designed for use as a trailing cable on AC mining equipment: 
  - Where maximum safety is mandatory, including underground mining machines where induced voltages in an unbalanced grounding system could be hazardous 
  - On low- and medium-voltage AC circuits where shielding is desired or required 

Features: 
• Flexible insulation shield provides shock hazard protection 
• Symmetrical grounding system does not produce induced voltages when operating in a balanced 3-phase system 
• Excellent heat, moisture, steam, oil, chemical and radiation resistance
• Flexible for easy handling 
• Resists cutting, impact, abrasion, flame and sunlight 
• Excellent thermal stability and physical properties over a broad temperature range 
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage —the cause of most portable cable failures

Compliances: 
• ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications 
• Meets flame test requirements and is accepted for listing by MSHA 
• Approved by the Pennsylvania Department of Environmental Protection 
• Meets CAN/CSA C22.2 No. 96 Portable Power Cables and is certified by Natural Resources Canada

Packaging: Material cut to length and shipped on nonreturnable reels

technical specifications:
cond. size(awg/kcmil) 1
no. of cond. 3
cond. strand 259
nominal insulation thickness(inches) 0.080
nominal insulation thickness(mm) 2.0
grd. cond. size(awg) 7
grd-check cond. size(awg) 16
nominal jacket thickness(inches) 0.190
nominal jacket thickness(mm) 4.8
nominal cable 0.d.(inches) 1.85
nominal cable 0.d.(mm) 47.0
copper weight(lbs/1000 ft) 1196
copper weight(kg/km) 1780
net weight(lbs/1000 ft) 2450
net weight(kg/km) 3645
ampacity 184
catalog number 13340.340100.ca