General Cable Anaconda® Brand Type SHD-GC Power Shielded Round Portable w/Ground-Check EPR CPE 5000 Volts Three Conductor

General Cable Anaconda® Brand Type SHD-GC Power Shielded Round Portable w/Ground-Check EPR CPE 5000 Volts Three Conductor

Select gauge from drop-down menu for prices:

General Cable Anaconda® Brand Type SHD-GC Power Shielded Round Portable w/Ground-Check EPR CPE 5000 Volts Three Conductor

Product Details

Conductor:  6 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172

Extruded Strand Shield (ESS): Extruded thermosetting semi-conducting stress control layer over conductor

Insulation: Ethylene Propylene Rubber (EPR) insulation colored for contrasting with black conducting layer

Insulation Shield: A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape

Ground-Check Conductor: Annealed copper, rope-lay-stranded per ASTM B172, insulated with high-strength yellow polypropylene

Grounding Conductors: 
• Coated copper, rope-lay-stranded per ASTM B172
• Two conductors in contact with the flexible copper braid shield

Jacket: Reinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE)

Jacket Marking: GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE SHD-GC 5000 VOLTS (-50C) FT1 FT5 CSA LR 27161 P-7K-102-046 MSHA

Options:
• Colored jackets are available
• TPU (Thermoplastic Polyurethane) jacket 
• Anamaxx® jacket

Applications:
• Designed for use as a trailing cable on AC mining equipment:
 - Where service conditions are severe and maximum safety is mandatory(such as power shovels and draglines in open-pit mines, quarries, gantry cranes and slag reclaiming) 
 - For high-voltage distribution in underground mines where frequent relocation is necessary

Features:
• Simultaneous extrusion and vulcanization of both strand shield and insulation form a virtually perfect electrode, eliminating unequal electrical stresses
• Excellent heat, moisture, steam, oil, corona, chemical and radiation resistance
• Flexible for easy handling
• High dielectric strength 
• Electrical stability under stress
• Low dielectric loss
• Resists cutting, impact, abrasion, flame and sunlight
• Excellent thermal stability and physical properties over a broad temperature range
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures

Compliances:
• ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection 
• Meets CAN/CSA C22.2 No. 96 Portable Power Cables and is certified by Natural Resources Canada

Packaging: Material cut to length and shipped on nonreturnable reels

cond.
size
(awg/
kcmil)
no. of
cond.
cond.
strand
nominal
insulation
thickness
grd.
cond.
size
(awg)
grd-
check
cond.
size
(awg)
nominal
jacket
thickness
nominal
cable0.d.
copper
weight
net
weight
ampacity General Cable
       And
Anaconda Brand
    Part Number
inches mm inches mm inches mm lbs/
1000 ft
kg/
km
lbs/
1000 ft
kg/
km
6 3 133 0.110 2.8 10 8 0.185 4.7 1.56 39.6 540 804 1560 2322 93 16241.210600.ca
4 3 259 0.110 2.8 8 8 0.185 4.7 1.68 42.7 720 1072 1895 2820 122 16204.858221.ca
2 3 259 0.110 2.8 6 8 0.205 5.2 1.87 47.9 1030 1533 2445 3639 159 16202.317964.ca
1 3 259 0.110 2.8 5 8 0.205 5.2 1.95 49.5 1248 1857 2800 4167 184 16201.396409.ca
1/0 3 259 0.110 2.8 4 8 0.220 5.6 2.08 52.8 1533 2281 3230 4807 211 16241.615100.ca
2/0 3 329 0.110 2.8 3 8 0.220 5.6 2.20 55.9 1854 2760 3800 5655 243 16252.271926.ca
3/0 3 413 0.110 2.8 2 8 0.235 6.0 2.36 59.9 2322 3456 4475 6660 279 16241.215300.ca
4/0 3 532 0.110 2.8 1 8 0.235 6.0 2.50 63.5 2936 4369 5265 7835 321 16254.730315.ca
250 3 608 0.120 3.0 1/0 6 0.250 6.4 2.69 68.3 3340 4970 6105 9085 355 16241.216000.ca
300 3 741 0.120 3.0 1/0 6 0.250 6.4 2.81 71.4 3962 5897 6875 10231 398 16241.216300.ca
350 3 851 0.120 3.0 2/0 6 0.265 6.7 2.95 74.9 4522 6730 7795 11600 435 16262.687414.ca
500 3 1221 0.120 3.0 4/0 6 0.280 7.1 3.31 84.1 6515 9696 10415 15499 536 16265.570479.ca

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question