General Cable Anaconda® Brand Type SHD-GC 350MCM Power Shielded Round Portable w/Ground-Check EPR CPE 5000 Volts Three Conductor

General Cable Anaconda® Brand Type SHD-GC 350MCM Power Shielded Round Portable w/Ground-Check EPR CPE 5000 Volts Three Conductor

Select gauge from drop-down menu for prices:

General Cable Anaconda® Brand Type SHD-GC 350MCM Power Shielded Round Portable w/Ground-Check EPR CPE 5000 Volts Three Conductor

Product Details

Conductor: 6 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172

Extruded Strand Shield (ESS): Extruded thermosetting semi-conducting stress control layer over conductor

Insulation: Ethylene Propylene Rubber (EPR) insulation colored for contrasting with black conducting layer

Insulation Shield: A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape

Ground-Check Conductor: Annealed copper, rope-lay-stranded per ASTM B172, insulated with high-strength yellow polypropylene

Grounding Conductors:
• Coated copper, rope-lay-stranded per ASTM B172
• Two conductors in contact with the flexible copper braid shield

Jacket: Reinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE)

Jacket Marking:GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE SHD-GC 5000 VOLTS P-7K-102-046 MSHA

Options:
• Colored jackets are available
• TPU (Thermoplastic Polyurethane) jacket
• Anamaxx® jacket

Applications:
• Designed for use as a trailing cable on AC mining equipment:
 - Where service conditions are severe and maximum safety is mandatory (such as power shovels and draglines in open-pit mines, quarries, gantry cranes and slag reclaiming)
 - For high-voltage distribution in underground mines where frequent relocation is necessary

Features:
• Simultaneous extrusion and vulcanization of both strand shield and insulation form a virtually perfect electrode, eliminating unequal electrical stresses
• Excellent heat, moisture, steam, oil, corona, chemical and radiation resistance
• Flexible for easy handling
• High dielectric strength
• Electrical stability under stress
• Low dielectric loss
• Resists cutting, impact, abrasion, flame and sunlight
• Excellent thermal stability and physical properties over a broad temperature range
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures

Compliances:
• ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection

Packaging:Material cut to length and shipped on nonreturnable reels

technical specifications:
cond. size (awg/kcmil)
350
no. of cond. 3
cond. strand 851
nominal insulation thickness(inches) 0.120
nominal insulation thickness(mm) 3.0
grd. cond. size(awg) 2/0
grd-check cond. size(awg) 6
nominal jacket thickness(inches) 0.265
nominal jacket thickness(mm) 6.7
nominal cable 0.d.(inches)
2.95
nominal cable 0.d.(mm) 74.9
copper weight(lbs/1000 ft) 4522
copper weight(kg/km)
6730
net weight(lbs/1000 ft) 7795
net weight(kg/km) 11600
ampacity 435
catalog number 16262.687414