General Cable Anaconda® Brand Type SHD-CGC 250MCM Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 2000 Volts Three Conductor

General Cable Anaconda® Brand Type SHD-CGC 250MCM Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 2000 Volts Three Conductor

Product Details

Conductor: 1 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172 

Insulation: Ethylene Propylene Rubber (EPR) insulation

Insulation Shield: A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape

Ground-Check Conductor:
• Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex fatigue
• Insulated with high-strength polypropylene and placed in the center interstice

Grounding Conductors: Three coated copper, rope-lay-stranded per ASTM B172 in contact with the flexible braid shield 

Jacket: Reinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE)

Jacket Marking: GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE SHD-CGC 2000 VOLTS P-7K-102-045 MSHA 

Options:
• Colored jackets are available
• TPU (Thermoplastic Polyurethane) jacket
• Anamaxx® jacket

Applications: 
• Designed for use as a trailing cable on AC mining equipment
- Where maximum safety is mandatory, including underground mining machines where induced voltages in an unbalanced grounding system could be hazardous
- On low- and medium-voltage AC circuits where shielding is desired or required

Features:
• Flexible insulation shield provides shock hazard protection
• Symmetrical grounding system does not produce induced voltages when operating in a balanced 3-phase system
• Excellent heat, moisture, steam, oil, chemical and radiation resistance
• Flexible for easy handling
• Resists cutting, impact, abrasion, flame and sunlight
• Excellent thermal stability and physical properties over a broad temperature range
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage —the cause of most portable cable failures

Compliances: 
• ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection

Packaging:Material cut to length and shipped on nonreturnable reels

technical specifications:
cond. size (awg/kcmil) 250
no. of cond.
3
cond. strand 608
nominal insulation thickness(inches)
0.095
nominal insulation thickness(mm) 2.4
grd. cond. size(awg)
2
grd-check cond. size(awg)
16
nominal jacket thickness(inches)
0.235
nominal jacket thickness(mm)
6.0
nominal cable 0.d.(inches)
2.51
nominal cable 0.d.(mm) 63.8
copper weight(lbs/1000 ft)
3290
copper weight(kg/km) 4896
net weight(lbs/1000 ft) 5440
net weight(kg/km) 8096
ampacity 355
catalog number 13340.646000

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.