General Cable Anaconda® Brand Type SHD-CGC 1/0 Gauge Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 5000 Volts Three Conductor

General Cable Anaconda® Brand Type SHD-CGC 1/0 Gauge Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 5000 Volts Three Conductor

Product Details

Conductor: 1 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172 
Extruded Strand Shield (ESS): Extruded thermosetting semi-conducting stress control layer over conductor 
Insulation: Ethylene Propylene Rubber (EPR) insulation colored for contrasting with black conducting layer 
Insulation Shield: A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape 
Ground-Check Conductor: 
• Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex fatigue 
• Insulated with high-strength polypropylene and placed in the center interstice 
Grounding Conductors: Three coated copper, rope-lay-stranded per ASTM B172 in contact with the flexible braid shield 
Jacket: Reinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE) 
Jacket Marking: GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE SHD-CGC 5000 VOLTS P-7K-102-046 MSHA 
Options: 
• Colored jackets are available 
• TPU (Thermoplastic Polyurethane) jacket 
• Anamaxx® jacket 
Applications: 
• Designed for use as a trailing cable on AC mining equipment: 
  - Where maximum safety is mandatory, including underground mining machines where induced voltages in an unbalanced grounding system could be hazardous 
  - On low- and medium-voltage AC circuits where shielding is desired or required 
Features: 
• Flexible insulation shield provides shock hazard protection 
• Symmetrical grounding system does not produce induced voltages when operating in a balanced 3-phase system  
• Excellent heat, moisture, steam, oil, chemical and radiation resistance 
• Flexible for easy handling 
• Resists cutting, impact, abrasion, flame and sunlight 
• Excellent thermal stability and physical properties over a broad temperature range 
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage —the cause of most portable cable failures 
Compliances: 
• ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications 
• Meets flame test requirements and is accepted for listing by MSHA 
• Approved by the Pennsylvania Department of Environmental Protection 
Packaging: Material cut to length and shipped on nonreturnable reels
technical specifications:
cond. size(awg/kcmil) 1/0
no. of cond. 3
cond. strand
259
nominal insulation thickness(inches) 0.110
nominal insulation thickness(mm) 2.8
grd. cond. size(awg)
6
grd-check cond. size (awg)
16
nominal jacket thickness(inches)
0.220
nominal jacket thickness(mm)
5.6
nominal cable 0.d.(inches) 2.10
nominal cable 0.d.(mm) 53.34
copper weight(lbs/1000 ft) 1473
copper weight(kg/km) 2192
net weight(lbs/1000 ft) 3319
net weight(kg/km) 4939
ampacity 211
catalog number 16299.065100