General Cable Anaconda® Brand Type G-CGC 250MCM Power Round Portable w/Extensible Ground-Check EPR CPE 2000 Volts Three Conductor

General Cable Anaconda® Brand Type G-CGC 250MCM Power Round Portable w/Extensible Ground-Check EPR CPE 2000 Volts Three Conductor

Product Details

Product Description:

Anaconda® Brand Type G-CGC Power Round Portable W/ Extensible Ground-Check EPR CPE 2000 Volts Three Conductors cables are three-conductor cables that include a neutral ground conductor.  The cable uses coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  The annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.

Applications:

Anaconda® Brand Type G-CGC Power Round Portable W/ Extensible Ground-Check EPR CPE 2000 Volts Three Conductors holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.  Type G-GC cable can be used in shipping and marine structures. 

Specifications:

-                In accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.

-                The cable also aligns with Underwriters Laboratories standard UL 1650, a standard that requires portable power cords to align with National Electric Code, NFPA 70.

-                The cable meets FT-5 flame test, a UL vertical flame test of 1,700 BTU.

-                The cable is compliant with Restrictions of Hazardous Substances and is approved by the Mining Safety and Health Administration.

Construction:

-                Conductors

  • The cable features two coated, rope-lay-stranded, annealed copper wire conductors.
  • The cable uses coated, rope-lay-stranded, annealed copper wires that align with ASTM B172.
  • The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. 

-                Ground Conductor

  • The assembly includes a coated copper, rope-lay-stranded ground conductor.
  • The ground conductor serves to ensure steady conductivity through the phase conductors.

-                Insulation

  • The annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).
  • EPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.

-                Jacket

  • The cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).
  • This material is resistant to oils, chemicals, high or low temperatures, and weather.
  • The jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.
technical specifications:
cond. size(awg/kcmil)
250
no. of cond. 3
cond. strand 608
nominal insulation thickness(inches) 0.095
nominal insulation thickness(mm) 2.4
grd. cond. size(awg) 2
grd-check cond. size(awg) 16
nominal cable 0.d.(inches)
2.39
nominal cable 0.d.(mm) 60.7
copper weight(lbs/1000 ft) 3070
copper weight(kg/km) 4569
net weight(lbs/1000 ft) 5015
net weight(kg/km) 7463
ampacity 320
catalog number 13329.646000