Popular Products

  • Anaconda Brand Type VFD-BGC Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 2000 Volts Three Conductor

    Select gauge from drop-down menu for prices:


    Free Shipping

    No End Date

    Click to View Shopping Cart

    Conductor: 2 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172

    Insulation: Ethylene Propylene Rubber (EPR) insulation, colored 

    Ground-Check Conductor:
    • Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex fatigue 
    • Insulated with high-strength polypropylene and placed in the center interstice
     
    Grounding Conductors: Three coated copper, rope-lay-stranded per ASTM B172 

    Shield: A flexible coated copper braid shield under an aluminum tape provides protection from radiated noise and a low transfer impedance path for the high frequency components of PWM signals 

    Jacket: Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE) 

    Jacket Marking: GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE VFD-BGC 2000 VOLTS 07-KA140006 MSHA

    Options:
    • Colored jackets are available 
    • Anamaxx® jacket

    Applications: 
    • Designed for use as a trailing cable on AC mining equipment:
       - From the inverter to the motor on variable frequency drive (PWM) systems
       - Where radiated EMI is causing interference with nearby systems 
       - Where a ground-check conductor is required for fail-safe ground monitoring 
       - With wireless ground monitoring systems

    Features:  
     • Flexible overall shield provides shock hazard protection
     • Symmetrical grounding system does not produce induced voltages when operating in a balanced three-phase system and minimizes common mode current in PWM drive systems 
     • Enhanced ground-check conductor has longer flex life and durability 
     • Excellent heat, moisture, steam, oil, chemical and radiation resistance 
     • Flexible for easy handling 
     • Resists cutting, impact, abrasion, flame and sunlight 
     • Excellent thermal stability and physical properties over a broad temperature range 
     • Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures 

    Compliances: 
    • Meets flame test requirements and is accepted for listing by MSHA  
    • Approved by the Pennsylvania Department of Environmental Protection 

    Packaging:  Material cut to length and shipped on non-returnable reels
    cond.
    size
    (awg/
    kcmil)
    no.
    of
    cond.
    cond.
    strand
    nominal
    insulation
    thickness
    grd.
    cond.
    size
    (awg)
    grd-check
    cond.
    size
    (awg)
    nominal
    jacket
    thickness
    nominal
    cable o.d.
    copper
    weight

    net weight
    ampacity General Cable 
    and Carol
    Brand Part 
    Number
    inches mm inches mm inches mm lbs/
    1000ft
    kg/
    km
    lbs/
    1000ft
    kg/
    km
    2 3 259 0.070 1.8 8 16 0.155 3.9 1.45 35.6 914 612 1620 2410 159 13373.030200
    1 3 259 0.080 2.0 7 16 0.170 4.3 1.64 41.6 1135 761 2050 3050 184 13373.030100
    1/0 3 259 0.080 2.0 6 16 0.170 4.3 1.74 44.2 1407 943 2420 3600 211 13373.035100
    2/0 3 329 0.080 2.0 5 16 0.170 4.3 1.81 46.0 1739 1165 2790 4160 243 13373.035200
    3/0 3 413 0.080 2.0 4 16 0.170 4.3 1.93 49.0 2149 1440 3850 5730 279 13373.035300
    4/0 3 532 0.080 2.0 3 16 0.190 4.8 2.09 53.2 2746 1840 4170 6210 321 13373.035400
    250 3 608 0.095 2.4 3 16 0.190 4.8 2.32 59.0 3102 2078 5660 8425 355 13373.036000
    350 3 851 0.095 2.4 1 16 0.220 5.6 2.64 67.0 4384 2937 7480 11132 435 13373.036200
    500 3 1221 0.095 2.4 1/0 16 0.220 5.6 2.95 75.0 6072 4068 9250 13770 536 13373.036500