General Cable Duralox® EPR AIA PVC Type MV-90 or MC 3C Power Nonshielded Armored UL

General Cable Duralox® EPR AIA PVC Type MV-90 or MC 3C Power Nonshielded Armored UL

Product Details

Conductors: 6 AWG thru 1000 kcmil bare copper, compact Class B strand

Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stress control layer over conductor

Insulation: Ethylene Propylene Rubber (EPR), colored to contrast with black conducting shield layer

Ground: Annealed bare copper Class B stranding per ASTM B8

Armor: Aluminum Interlocked Armor (AIA)

Jacket: Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), yellow

Options: Galvanized Steel Interlocked Armor (GSIA)

Applications:
• Ideally suited for use in a broad range of commercial, industrial and utility applications where reliability is the major concern, maximum performance will be demanded, space is limited, ease of installation is critical and fire resistance is necessary
• May be installed in wet or dry locations, indoors or outdoors and in exposed or concealed work
• May be used in cable trays or on approved supports in protected areas
• Permitted for use per NEC Article 334 - Class I, Division 2 - Class II, Division 2 - Class III, Divisions 1 and 2

Features:
• Rated at 90?C wet or dry
• Excellent heat and moisture resistance
• Outstanding corona resistance
• Flexibility for easy handling
• High dielectric strength
• Low moisture absorption
• Electrical stability under stress
• Low dielectric loss
• Chemical- and radiation-resistant
• Excellent crush resistance
• Flame or sunlight resistance
• Cost-effective alternative to installations in conduit
• Meets cold bend test at -40?C
• 90°C rating for continuous operation
• 130°C rating for emergency overload conditions
• 250°C rating for short circuit conditions

Compliances:
Industry Compliances:
• UL 1569
• UL 1072
• ICEA S-96-659/NEMA WC71
• UL Type MV-90, UL File # E90501
• UL Type MC, UL File # E90496
Flame Test Compliances:
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)
• ICEA T-30-520 (70,000 BTU/hr)
Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable

Packaging: Material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing