Popular Products

  • HVTECK 3C TRXLPE Tape Shield AIA PVC Power Shielded Armored 28kV and 35kV 345 Mils CSA

    Select gauge from drop-down menu for prices:


    Free Shipping

    No End Date

    Click to View Shopping Cart

    Conductor: 1/0 AWG thru 350 kcmil bare copper compact Class B strand

    Strand Shield: A thermoset semi-conducting strand shield is extruded over the conductor

    Insulation: Tree-Retardant Cross-linked Polyethylene (TRXLPE)

    Insulation Shield:
    • This consists of a semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape
    • Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield

    Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor

    Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

    Armor: Aluminum Interlocked Armor (AIA)

    Overall Jacket: Lead-free, ACID-FLAME-CHECK ✓✓® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black or as requested

    Options: Galvanized Steel Interlocked Armor (GSIA)

    Applications:
    • For wiring in all hazardous locations when used with certified HL cable glands
    • For exposed and concealed wiring in dry, damp or wet locations
    • For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
    • For direct earth burial (with protection as required by inspection authority)

    Features:
    • Rated at 90˚C wet or dry
    • Excellent crush, oil and chemical resistance
    • Provides long service life
    • Cost-effective alternative to installations in conduit
    • Meets cold bend and impact tests at -40˚C

    Compliances:
    Industry Compliances:
    • CSA Standard C22.2 No. 131 and No. 174
    • CSA Standard C68.10

    Flame Test Compliances:
    • CSA FT1 and FT4
    • IEEE 383 (70,000 BTU/hr)
    • UL 1581 (70,000 BTU/hr)
    • IEEE 1202 (70,000 BTU/hr) CSA FT4
    • ICEA T-30-520 (70,000 BTU/hr)
    • ICEA T-29-520 (210,000 BTU/hr)

    Other Compliances:
    • Hazardous Location Rating: HL
    • EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA Acceptable
    • RoHS Compliant

    Packaging:
    • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
    • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

    cond.
    size
    (awg/
    kcmil)
    no.
    of
    cond.
    grnd
    wire
    size
    (awg)
    nominal diameter (over) copper weight net weight w/ armor outdoor
    amp**
    (40˚c
    ambient)
    general cable
    part number
    insulation
    (inches)
    insulation
    shield
    (inches)
    inner
    jacket
    (inches)
    armor
    (inches)
    cable
    (inches)
    lbs/
    1000ft
    kg/
    km
    lbs/1000 ft kg/km
    al steel al steel
    1/0 3 6 1.08 1.17 2.76 3.05 3.18 1200 1786 4360 5620 6490 8370 187 17496.895100*
    2/0 3 6 1.12 1.21 2.92 3.21 3.36 1466 2182 4950 6280 7370 9350 215 17496.895200*
    3/0 3 4 1.17 1.26 3.02 3.31 3.46 1848 2750 5490 6860 8160 10210 245 17496.895300*
    4/0 3 4 1.22 1.31 3.14 3.43 3.58 2264 3369 6090 7510 9060 11180 281 17496.895400*
    250 3 4 1.27 1.37 3.26 3.55 3.70 2635 3921 6660 8140 9910 12120 310 17496.896000*
    350 3 3 1.42 1.51 3.56 3.85 4.00 3621 5389 7960 9540 11840 14190 377 17496.896200*

    Quick Quote Form 

    * Indicates required field

    Receive A Response In 5 Minutes Or Less During Regular Business Hours

    Captcha Image

    This product has no related products.