    Conductor: Solid or Class B compact or compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.

    Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.

    Insulation: Natural high dielectric strength VOLTENE™ TRXLPE insulation, exhibiting an optimum balance of mechanical and electrical properties, insuring resistance to treeing.

    Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.

    Metallic Shield: Solid bare copper wires, helically applied and uniformly spaced.

    Jacket: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes.

    Description: Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength VOLTALENE™ TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket.

    Options:
    • Black LLDPE jacket with no stripes
    • Black PVC jacket sleeved over separator tape
    • No Jacket
    • EPROTENAX™ (EPR) insulation
    • Multiplex cables
    • Tinned round and flat strap neutrals
    • Strandseal®
    • Super smooth conductor shield
    • Cables made to AEIC CS8 and/or ICEA S-94-649
    • 46kV

    Installations:
    • Conduit in Air
    • Direct Buried
    • Underground Duct
    • Isolated in Air
    • Wet Locations
    • Dry Locations
    • With Messenger
    • Utility Primary

    Specifications and Ratings:
    • CSA - CSA C68.5 -40°C
    • For 90°C continuous, 130°C emergency, 250°C short-circuit operation.

    conductor insulation
    thickness
    (mils)
    concentric
    neutral

    cond.
    dia.(in)
    ins.
    dia.
    (in)
    ins.
    shield
    diameter (in)
    jacket
    dia.(in)
    cable
    weight
    (lbs/kft)
    min.
    bending
    radius (in)

    amp.
    (amps)
    +/- sequence
    imp.
    resistance
    (µΩ/ft)
    +/- sequence
    imp.
    reactance
    (µΩ/ft)

    amp.
    (amps)
    +/- sequence
    imp.
    resistance
    (µΩ/ft)
    +/- sequence
    imp.
    reactance
    (µΩ/ft)
    prysmian
    cable
    part
    number
    (a) (b) (c) (d) 90°c in duct 90°c direct buried
    28kv 100% aluminum single phase - full neutral
    1 solid al 280 13-#14 7.34 23.04 24.92 31.02 1004 254 146 1.70 0.11 192 1.70 0.11 QVN01ZC
    1 awg al 280 13-#14 7.65 23.24 25.12 31.22 1014 254 146 1.72 0.11 192 1.72 0.11 QVO01ZC
    1/0 solid al 280 16-#14 8.26 23.95 25.83 31.93 1118 279 165 1.36 0.10 218 1.36 0.10 QVP01ZC
    1/0 awg al 280 16-#14 8.59 24.18 26.06 32.16 1130 279 165 1.38 0.10 217 1.38 0.10 QVQ01ZC
    2/0 awg al 280 13-#12 9.60 25.20 27.08 34.03 1328 279 189 1.08 0.10 247 1.08 0.10 QVR01ZC
    3/0 awg al 280 16-#12 10.82 26.42 28.75 35.70 1526 305 216 0.86 0.10 281 0.86 0.10 QVS01ZC
    4/0 awg al 280 20-#12 12.14 27.74 30.07 37.02 1709 305 245 0.69 0.09 319 0.69 0.09 QVT01ZC
    250 MCM al 280 23-#12 13.28 29.13 31.47 38.42 1985 330 268 0.59 0.09 348 0.59 0.09 QVU01ZC
    350 MCM al 280 33-#12 15.72 31.57 33.91 40.86 2511 330 327 0.42 0.08 423 0.42 0.08 QVV01ZC
    28kv 100% aluminum three phase - one-third neutral
    1 solid al 280 10-#16 7.34 23.04 24.92 30.34 854 254 146 0.86 0.17 195 0.88 0.33 QVN00ZC
    1 awg al 280 10-#16 7.65 23.24 25.12 30.55 864 254 145 0.87 0.17 194 0.90 0.33 QVO00ZC
    1/0 solid al 280 11-#16 8.26 23.95 25.83 31.26 926 254 166 0.68 0.17 221 0.71 0.32 QVP00ZC
    1/0 awg al 280 11-#16 8.59 24.18 26.06 31.49 937 254 165 0.70 0.17 220 0.73 0.32 QVQ00ZC
    2/0 awg al 280 11-#16 9.60 25.20 27.08 32.50 1010 279 188 0.55 0.16 249 0.58 0.31 QVR00ZC
    3/0 awg al 280 14-#16 10.82 26.42 28.75 34.18 1163 279 214 0.44 0.16 281 0.47 0.30 QVS00ZC
    4/0 awg al 280 17-#16 12.14 27.74 30.07 35.50 1252 305 243 0.35 0.15 314 0.39 0.29 QVT00ZC
    250 MCM al 280 21-#16 13.28 29.13 31.47 36.90 1465 305 266 0.30 0.15 340 0.34 0.28 QVU00ZC
    350 MCM al 280 27-#16 15.72 31.57 33.91 39.33 1759 330 320 0.21 0.14 395 0.27 0.26 QVV00ZC
    500 MCM al 280 25-#14 18.80 34.65 36.98 44.51 2351 381 386 0.16 0.13 449 0.22 0.23 QVW00ZC
    750 MCM al 280 24-#12 23.11 39.22 42.42 50.79 3279 406 470 0.11 0.13 509 0.18 0.19 QVX00ZC
    1000 MCM al 280 31-#12 26.92 43.03 46.23 54.60 3987 457 531 0.09 0.12 552 0.16 0.17 QVY00ZC