General Cable EmPowr® 220 Miles 15 kV 350MCM Copper Wire PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation

General Cable EmPowr® 220 Miles 15 kV 350MCM Copper Wire PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation

Select gauge from drop-down menu for prices:

General Cable EmPowr® 220 Miles 15 kV 350MCM Copper Wire PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation
EmPowr 220 Miles 15 kV 350MCM Copper Wire PVC Jacket Link and Shielded Power Cable Al Conductor TRXLPE Insulation

Complete Cable: Lead-free cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper wires (helically applied), separator tape and overlaying black PVC jacket are applied over the cable core. These products meet the latest requirements of ANSI/ICEA S-97-682 and AEIC CS8 as applicable for Tree-Retardant Cross-linked Polyethylene(TRXLPE) insulated shielded power cable.

Conductor: Solid or Class B compressed concentric lay stranded 1350 aluminum.

Conductor Shield: Extruded lead-free semi-conducting thermosetting polymeric stress control layer.

Insulation: Extruded unfilled lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).

Insulation Shield: Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation.

Copper Wire Shield: Helically applied annealed solid bare copper wires with a lapped non-metallic tape serving as a binder/separator.

Jacket: Black, non-conducting, sunlight-resistant Polyvinyl Chloride (PVC).

Features and Benefits:
• Lead-free environmentally friendly cable
• Triple-extruded for clean interfaces
• Dry nitrogen cure for enhanced performance
• Class 10,000 environment utilized for cable core material handling
• Excellent moisture resistance
• High dielectric strength
• Low dielectric loss
• Excellent resistance to water treeing
• Clean-stripping insulation shield
• Sunlight-resistant

Temperature Rating:
• Normal - 90°C
• Emergency* - 130°C
• Short Circuit - 250°C

Applications: EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of threephase medium-voltage power. These cables may be installed in ducts or direct buried.

Options:
• Copper conductors
• STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610
• True Triple Extrusion
• UltraPowr® smoother and cleaner semi-conducting conductor shield
• Low-strip insulation shield
• 3 X 1/C triplex or parallel
• Type MV-90 UL 1072
• TRXLPE Class III insulation for 105°/140°C temperature rating
• Type MV-105 UL 1072
• UL Listed

technical specifications:
compressed conductor(al awg or kcmil) 350
compressed conductor(no.of wires) 37
copper neutral(no.of wires) 6
copper neutral(wire size awg)
20
diameter (1) inches (min. insulation ) 1.105
diameter (1) inches (max. insulation) 1.190
diameter (1) inches (pvc jacket) 1.439
nominal jacket thkn. inches (1) 0.080
approx. weight (1) lb/1000 ft(al cond.) 329
approx. weight (1) lb/1000 ft(cu wires) 20
approx. weight (1) lb/1000 ft(total)
899
ampacity (2)(direct buried) 425
ampacity (2)(in duct) 335

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question