Prysmian Cable 4/0 AWG Three Conductor CU Airguard UL Type MV-105 25kV 133% Medium Voltage Commercial, Industrial Cable QQB580A

Prysmian Cable 4/0 AWG Three Conductor CU Airguard UL Type MV-105 25kV 133% Medium Voltage Commercial, Industrial Cable QQB580A

Select gauge from drop-down menu for prices:

Prysmian Cable 4/0 AWG Three Conductor CU Airguard UL Type MV-105 25kV 133% Medium Voltage Commercial, Industrial Cable QQB580A
Prysmian Cable 4/0 AWG Three Conductor CU Airguard UL Type MV-105 25kV 133% Medium Voltage Commercial, Industrial Cable QQB580A

Conductor: Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. 

Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. 

Insulation: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. 

Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. 

Metallic Shield: Helically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w/ Red, 1C w/ Blue, and 1C w/ Black. 

Grounding Conductors: Bare stranded copper conductor per UL, ICEA, and ASTM. 

Assembly: Phase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability. 

Mechanical Protection: High strength and high crush resistant Air Bag™ layer extruded over the core assembly. 

Chemical Protection: A layer of Drylam™ which consists of aluminum tape and a chemical resistant extruded polymer layer is applied. 

Jacket: Sunlight and moisture resistant polyvinyl chloride (PVC) jacket. 

Installation: 
• In Cable Tray 
• Direct Buried 
• Isolated in Air 
• Dry Locations With Messenger 
• Conduit in Air 
• Underground Duct 
• Wet Locations Industrial 

Specifications and Ratings:
• ICEA- ICEA S-93-639/NEMA WC74 
• UL 1072 Type MV-105, For CT USE Direct Buried Sunlight Resistant 
• IEEE 383 & 1202 Flame Test 
• CSA FT4 Flame Test CSA Cold Impact/Bend Test (-40C) 
• MSHA Type MP and Type MP-GC

technical specification:
conductor 4/0 AWG CU
insulation thickness (mils) 320
ground wires no. 3
ground wires size 7 AWG
conductor diameter (in) (a) 0.479
insulation diameter (in) (b) 1.16
insulation shield diameter (in) (c) 1.22
overall jacket diameter (in) (d) 3.28
cable weight (lbs/kft) 6811
minimum bending radius (in) 23
ampacity (amps) ‡105°c in duct 305
ampacity (amps) ‡105°c in air/tray 360
impedance (micro-ohms/foot) pos/neg seq 68 + j44
impedance (micro-ohms/foot) zero seq. 516 + j28
prysmian cable part number QQB580A