General Cable FREP® FR-EPR CPE Type TC-ER1 10/2 Flat Gauge E-1 Color Code Control Unshielded 600V UL

General Cable FREP® FR-EPR CPE Type TC-ER1 10/2 Flat Gauge E-1 Color Code Control Unshielded 600V UL

Select gauge from drop-down menu for prices:

General Cable FREP® FR-EPR CPE Type TC-ER1 10/2 Flat Gauge E-1 Color Code Control Unshielded 600V UL
FREP FR-EPR CPE Type TC-ER1 10/2 Flat Gauge E-1 Color Code Control Unshielded 600V UL

Conductor:
• 14 AWG thru 10 AWG fully annealed stranded tinned copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:
• Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
• Color-coded per ICEA Method 1, Table E-1 (includes white or green)

Jacket: Lead-free, flame-retardant thermoplastic Chlorinated Polyethylene (CPE)

Applications:
• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors
• Approved for direct burial
• Class I, Division 2 industrial hazardous locations per NEC

Features:
• Rated at 90?C wet or dry
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Excellent physical, thermal and electrical properties
• Sunlight- and weather-resistant
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat deformation
• Low coefficient of friction for easy pulling
• Excellent flame resistance—burns to ash; does not exhibit thermoplastic drip
• Excellent low temperature cold bend characteristics
• Meets cold bend test at -40?C
• Meets the crush and impact requirements of Type MC cable for 3 or more conductors

Compliances:
Industry Compliances:
• UL 44 Type XHHW-2
• UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179
• UL 1581
• ICEA S-73-532/NEMA WC57

Flame Test Compliances:
• UL 1581/UL 2556 VW-1
• UL 1685 Vertical Flame Test
• IEEE 383
• IEEE 1202
• CSA FT4
• ICEA T-29-520

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable
• RoHS Compliant

Packaging: Material cut to length and shipped on non-returnable wood reels

technical specification:
cond. size (awg) 10
no. of cond. 2 Flat
cond. strand 7W
minimum avg. insulation thickness(inches) 0.030
minimum avg. insulation thickness(mm) 0.76
minimum avg. jacket thickness(inches) 0.045
minimum avg. jacket thickness(mm) 1.14
nominal cable o.d.(inches) 0.445 x 0.270
nominal cable o.d.(mm) 11.30 x 6.90
copper weight(lbs/ 1000 ft) 64
copper weight(kg/km) 95
net weight(lbs/ 1000 ft) 113
net weight(kg/km) 168
catalog number 280600*