General Cable TC-Flex® Tray Cable 18/19 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Torsion-Resistant Flame-Retardant

General Cable TC-Flex® Tray Cable 18/19 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Torsion-Resistant Flame-Retardant

Select gauge from drop-down menu for prices:

General Cable TC-Flex® Tray Cable 18/19 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Torsion-Resistant Flame-Retardant
TC-Flex Tray Cable 18/19 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Torsion-Resistant Flame-Retardant

Conductors: 18 AWG (1,0 mm²) and 16 AWG (1,5 mm²) fully annealed flexible stranded bare copper with Class 5 stranding per EN 60228 (IEC 60228)

Insulation: Polyvinyl Chloride (PVC) insulation with Polyamide (nylon) jacket per UL 83

Conductor Identification: Conductors are black with printed numbers and green/yellow grounding conductor

Cable Assembly: Conductors cabled with non-hygroscopic fillers to make the cable suitably round

Jacket: Black, flexible, flame-retardant, sunlight- and oilresistant Polyvinyl Chloride (PVC) jacket

Minimum Bending Radius:
• 4x O.D. for fixed installation
• 8x O.D. for flexing applications

Torsion: 10,000 cycles at -40°C, +/- 150° twist per meter, cable weight compensated to 20 meters

Applications:
• In free air, raceways or direct burial
• (UL) WTTC cables for use up to 1000 V in wind turbine generator applications in accordance with UL Subject 6140
• (UL) TC-ER cables for use up to 600 V as power and control cables in accordance with NEC® Article 336
• (UL) MTW cables for machine tool and wire up to 600 V as power and control cables in accordance with UL 1063
• (CSA) CIC/TC cables for use up to 600 V in cable trays and other applications when installed in accordance with the Canadian Electrical Code, Part I
• (CSA) AWM cables for use up to 1000 V as equipment wiring in accordance with the Canadian Electrical Code, Part I

Specifications:
Design Adherence:
• UL 66 & UL 83/CSA C22.2 No. 75-08 Thermoplastic Insulated Wires
• UL 1063/MTW Machine Tool Wire
• UL 1277 Power and Control Tray Cables
• UL 2277 Wind Turbine Tray Cables
• CSA C22.2 No. 230-09 Tray Cables
• CSA C22.2 No. 239-09 Control and Instrumentation Cables
• CSA C22.2 No. 210-11 Appliance Wiring Material Products

Flame Tests: IEEE 1202/CSA FT4

Compliances:
• Type TC-ER 90°C Dry, 75°C Wet, 600 V
• Type MTW
• Type WTTC 90°C, 1000 V
• Type CIC/TC 90°C, 600 V
• Type AWM I/II A/B, 90°C, 1000 V FT4
• RoHS Compliant

technical specification:
cond. size (awg) 18
no. of cond. inc. grnd. 19
nom. ins. thickness(inches) 0.021
nom. ins. thickness(mm) 0.53
nom. jacket thickness(inches) 0.063
nom. jacket thickness(mm) 1.60
nom. cable o.d.(inches) 0.623
nom. cable o.d.(mm) 15.8
nom. copper weight(lbs/1000ft) 111
nom. copper weight(kg/km) 165
nom. cable weight(lbs/1000ft) 229
nom. cable weight(kg/km) 340
90°c amp. @ 30°c ambient¹ 6
catalog number 4775.19018