General Cable TC-Flex® Shielded Tray Cable 8/4 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Flame-Retardant

General Cable TC-Flex® Shielded Tray Cable 8/4 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Flame-Retardant

Select gauge from drop-down menu for prices:

General Cable TC-Flex® Shielded Tray Cable 8/4 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Flame-Retardant
TC-Flex Shielded Tray Cable 8/4 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Flame-Retardant

Conductors: 14 AWG (2,5 mm²) thru 2 AWG (35,0 mm²) fully annealed flexible stranded bare copper with Class 5 stranding per EN 60228 (IEC 60228)

Insulation: Polyvinyl Chloride (PVC) insulation with Polyamide (nylon) jacket per UL 83

Conductor Identification: Conductors are black with printed numbers and green/yellow grounding conductor

Cable Assembly: Conductors cabled with non-hygroscopic fillers to make the cable suitably round

Shield: Aluminum/Mylar foil shield providing 100% coverage in combination with a tinned copper braid providing 85% nominal coverage

Jacket: Black, flexible, flame-retardant, sunlight- and oil-resistant Polyvinyl Chloride (PVC) jacket

Minimum Bending Radius:
• 4x O.D. for fixed installation
• 8x O.D. for flexing applications

Applications:
• In free air, raceways or direct burial
• (UL) WTTC cables for use up to 1000 V in wind turbine generator applications in accordance with UL Subject 6140
• (UL) TC-ER cables for use up to 600 V as power and control cables in accordance with NEC® Article 336
• (UL) MTW cables for machine tool and wire up to 600 V as power and control cables in accordance with UL 1063
• (CSA) CIC/TC cables for use up to 600 V in cable trays and other applications when installed in accordance with the Canadian Electrical Code, Part I
• (CSA) AWM cables for use up to 1000 V as equipment wiring in accordance with the Canadian Electrical Code, Part I

Specifications:
Design Adherence:
• UL 66 & UL 83/CSA C22.2 No. 75-08 Thermoplastic Insulated Wires
• UL 1063/MTW Machine Tool Wire
• UL 1277 Power and Control Tray Cables
• UL 2277 Wind Turbine Tray Cables
• CSA C22.2 No. 230-09 Tray Cables
• CSA C22.2 No. 239-09 Control and Instrumentation Cables
• CSA C22.2 No. 210-11 Appliance Wiring Material Products

Flame Tests: IEEE 1202/CSA FT 4

Compliances:
• Type TC-ER 90°C Dry, 75°C Wet, 600 V
• Type MTW
• Type WTTC 90°C, 1000 V
• Type CIC/TC 90°C, 600 V
• Type AWM I/II A/B, 90°C, 1000 V FT4
• RoHS Compliant

technical specification:
cond. size (awg) 8
no. of cond. inc. grnd. 4
nom. ins. thickness(inches) 0.039
nom. ins. thickness(mm) 0.99
nom. jacket thickness(inches) 0.063
nom. jacket thickness(mm) 1.60
nom. cable o.d.(inches) 0.735
nom. cable o.d.(mm) 18.7
nom. copper weight(lbs/1000ft) 280
nom. copper weight(kg/km) 417
nom. cable weight(lbs/1000ft) 412
nom. cable weight(kg/km) 613
90°c amp. @ 30°c ambient¹ 55
catalog number 4790.04008

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question