Helukabel 4 AWG 4 Cores Topserv 600 VFD EMC Preferred Type Highly Flexible Motor Power Supply Cable NFPA79 Edition 2012 Black Cable 62614

Helukabel 4 AWG 4 Cores Topserv 600 VFD EMC Preferred Type Highly Flexible Motor Power Supply Cable NFPA79 Edition 2012 Black Cable 62614

Select gauge from drop-down menu for prices:

Helukabel 4 AWG 4 Cores Topserv 600 VFD EMC Preferred Type Highly Flexible Motor Power Supply Cable NFPA79 Edition 2012 Black Cable 62614
Helukabel 4 AWG 4 Cores Topserv 600 VFD EMC Preferred Type Highly Flexible Motor Power Supply Cable NFPA79 Edition 2012 Black Cable 62614

Technical data:
• TPE motor supply cable acc. to UL-Std.1277 and UL-Std.2277

Temperature range
• -25°C to +90°C

Nominal voltage
• TC 600 V
• WTTC 1000 V

Test voltage
• 4000 V

Minimum bending radius
• flexing 5x cable Ø
• permanently flexing 7,5 cable Ø

Coupling resistance
• max. 250 Ohm/km

Cable structure:
• Tinned copper conductor, extra fine wire with AWG dimensions
• Core insulation of special PVC with transparent nylon skin
• Black cores with continuous white numbering
• GN-YE conductor in the outer layer
• Cores stranded in layers with optimal lay-length
• Fleece
1. Screening with special aluminium foil
2. Screening with braid of tinned copper wires, optimal coverage approx. 85%
• Separator
• Outer sheath of special TPE
• Sheath colour black (RAL 9005) or orange (RAL 2003)
• with length marking in feet

Properties:
• self-extinguishing and flame retardant acc. to CSA FT4
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
• UV-resistant

Tests:
UL:
TC-ER, WTTC 1000 V, MTW, NFPA 79 2012,
PLTC-ER (AWG 18 - AWG 12),
ITC-ER (AWG 18 - AWG 12) OIL RES I & II,
90°C dry / 75°C wet, Cold Bend Test -40°C
Class 1 Div. 2 per NEC Art. 336, 392, 501
CSA:
c (UL) CIC-TC FT4
AWM I/II A/B FT4

Note:
• VFD = Variable Frequency Drive

Application:
Highly-flexible, extremely oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage) and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures. Approved to NFPA 79 edition 2012 for open, unprotected installation on cable trays and from cable trays to the machine. The special TPE sheath is extremely resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes and in the earth.
EMC = Electromagnetic compatibility
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.

technical specification:
awg-no. 4
no.cores 4
cross section mm² 21,21
outer ø app. mm 30,1
cop. weight kg/km 960,0
weight app. kg/km 1364,0
helukabel part number 62614

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question