General Cable Low-Smoke® Unarmored Thermoplastic 2 Fibers Zero-Halogen Lite-Duty Breakout Cable ABS Type Approval (RQS)

General Cable Low-Smoke® Unarmored Thermoplastic 2 Fibers Zero-Halogen Lite-Duty Breakout Cable ABS Type Approval (RQS)

Product Details

Central Strength Member: Epoxy glass rod 

Optical Fiber Cable Component (OFCC): 
Fiber: 
• 2-24 fibers (see Fiber Selection Guide) 
• Color Code: White–numbered “1-ONE,” “2-TWO,” “3-THREE,” etc. 
• Buffer: polyester elastomer 900μm 6 50μm 

Strength Member: Aramid yarn longitudinally applied 

jacket: Low-Smoke thermoplastic Polyolefin: .078" (2.0 mm) nom. diameter 

Binder Tape: Mylar tape 

Outer Sheath: Low-Smoke, Zero-Halogen (LSZH), low-toxicity, thermoplastic Polyolefin – Black 

Applications: Offshore platforms, ships, mobile oil rigs, FPSOs, land rigs, onshore drilling 

Features: 
• Breakout-style cable 
• Temperature: -40°C to +70°C 
• Gigabit Ethernet compliant 
• LSZH, thermoplastic, UV-resistant sheath to insure overall maximum flexibility, oil and chemical resistance
• Standards-compliant, cost-effective solution 

Compliances: 
Fiber:  
• ANSI/TIA/EIA 568 B.3 
• GR-409 
• Temp. Cycling- FOTP-3 
• Low and High Temp. Bend- FOTP-31 
• Cable External Freezing- FOTP-98 
• Cyclic Flexing- FOTP-104 
• Compressive Loading- FOTP-41 
• Cable Twist- FOTP-85 

Flame/Safety Test: 
• Flame- OFNR, UL 1666, IEEE 383 Pending 
• Halogen Content- IEC 60754-1 & -2 
• Smoke Density- IEC 61034-1 & -2 
• Acidity- IEC 60754-2 

Third-Party Testing: 
• MET Labs has tested and confirmed that this product complies with the mechanical test in the above specification (report number F026746-GEN rev1) 
• ETL has tested and confirmed that this product complies with the flame test in the above specification (report number 3174223CRT-001)

technical specification
fiber count 2
nom. outer sheath diameter(inches) 0.284
nom. outer sheath diameter(mm) 7.20
nom. outer sheath thickness(inches) 0.045
nom. outer sheath thickness(mm) 1.14
maximum weight(lbs/ 1000 ft) 36
maximumweight(kg/km) 54
minimum bend radius(installation inches/cm) 4.3/10.8
minimum bend radius(in-service inches/cm) 2.8/7.2
maximum tensile load(installation lbs/n) 200/600
maximum tensile load(in-service lbs/n) 50/225
general cable part number xx0021c1z-tpl

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question