Popular Products

  • Prysmian and Draka Cable Dry FusionLink Armored Ribbon central tube Cable

    Features and Benefits:

    Compact Design:
    • Efficient packaging of higher fiber counts
    • Lightweight and easy to handle during installation

    Easily Removable Ribbon Matrix:
    • Allows for ease of stripping and fiber breakout
    • Improves mid-span strippability

    Precision Ribbon Geometry: Time and labor savings during fiber splicing

    Flexible Buffer Tube:
    • Superior kink resistance
    • Increased flexibility
    • Facilitates route management in closures

    Dry Water-Blocking Technology:
    • Buffer tube and core are completely dry—no gel
    • Permits rapid cable preparation and termination
    • Water-blocking materials are easily removed

    ezPrep® Corrugated Steel Armor:
    • Provides additional mechanical protection
    • Special coating reduces time and effort to remove jacket

    Available Uncoupled or Coupled Designs:
    • Coupled design (RCD product >48F) couples the ribbon stack with the cable which elimates the need for splice point coupling coils in aerial application
    • Un-coupled design (RCU product) requires the use of coupling coils at the splice points in aerial applications to prevent fiber retraction in closures

    Performance:
    • Meets or exceeds the requirements of Telcordia GR-20 & ICEA 640 and is tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables
    • Tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables
    • Complies with RUS PE-90

    Registered Supplier: ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

    performance specifications
    bend radius
    dynamic
    static
    20 x cable od
    10 x cable od
    tensile rating
    installation
    residual
    n
    2700
    800
    lbf
    600
    180
    crush resistance
    short/ long term
    n/cm
    220/110
    lbf/in
    125/63
    temperature ratings
    operation
    installation
    storage/shipping
    °c
    -40 to +70
    -30 to +60
    -40 to +75
    °f
    -40 to +158
    -22 to +140
    -40 to +167

    Nominal Design Parameters
    fiber
    count
    ribbon
    count
    fibers/
    ribbon
    aerial coupling
    coils required
    (rcd)
    aerial coupling
    coils required
    (rcu)
    buffer tube od cable od cable weight max. length
    (mm) (inches) (mm) (inches) (kg/km) (lb/kft) (m) (ft)
    12-48 1-4 12 non available yes 6.2 0.24 12.5 0.50 152 102 11,187 36,693
    60-72 5-6 12 no yes 8.8 0.35 16.3 0.64 224 151 11,187 36,693
    84-96 7-8 12 no yes 9.5 0.37 17.0 0.67 233 157 10,095 33,111
    108-144 9-12 12 no yes 10.6 0.42 18.1 0.71 258 173 8,880 29,126
    156-216 13-18 12 no yes 12.3 0.48 19.8 0.78 285 192 7,580 24,862
    240-432* 10-18 24 no yes 15.4 0.61 22.9 0.90 353 237 5,445 17,864

    Quick Quote Form 

    * Indicates required field

    Receive A Response In 5 Minutes Or Less During Regular Business Hours

    Captcha Image

    This product has no related products.

Related Products