HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 7 Conductors

HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 7 Conductors

Select gauge from drop-down menu for prices:

HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 7 Conductors
HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6/1kV 90°C Gexol® Insulation - 10 AWG - 7 Conductors
Technical Specifications:
Catalog Number/HWC Part # HW290 01007
Size AWG/kcmil 10
Size (mm2) 5.2
Number of Conductors 7
Grounding Conductor AWG/kcmil 10
Nominal Diameter (inches) 0.930
Weight (lbs./1000 ft.) 488
90°C NEC Ampacity 28
75°C NEC Ampacity 24
DC Resistance at 25°C(Ohms/1000 ft.) 1.15
AC Resistance at 90°C, 60 Hz (Ohms/1000 ft.) 1.44
Voltage Drop (Volts/Amp/1000 ft.) 2.031
HL Listed *

Specifications:

  • HW290
  • Listed CIR® Control Cable*
  • Multi-Conductor + Ground
  • 0.6/1kV 90°C Gexol® Insulation

Application:
Designed and constructed to be a flexible alternative to Type MC cable where crush and impact protection in arctic conditions is required.

Conductors:
Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.

Insulation:
Gexol cross-linked flame retardant polyolefin, meets requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. 600V/IEC 1000V.

Grounding Conductor:
Soft annealed, flexible stranded, insulated, tinned copper sized in accordance with UL 1277.

Jacket:
A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 1309/CSA 245 and IEEE 1580.

Ratings & Approvals :

  • 90°C temperature rating
  • UL Listed as Marine Shipboard Cable (E111461)
  • UL Listed as Type TC-ER
  • UL Listed as Type TC-ER-HL*
  • American Bureau of Shipping (ABS) (99-BT5905-X)
  • Flame Retardant – IEEE 1202
  • Suitable for use in Class I, Div 2 & Zone 2 environments
  • Suitable for use in Class I, Div 1 & Zone 1 environments*
  • *Cables up to 1” in OD

Features:

  • Complies with the requirements for TC-ER-HL* per UL 2225
  • Gas & vapor tight – impervious to water and air
  • Smaller bend radius (up to 40% smaller) than Type MC
  • Reduced tray fill (up to 35% less) compared to Type MC
  • Considerably more flexible than Type MC
  • Brittle point as per ASTM D 746-07 exceeds -65°C for Jacket and -75°C for Insulation
  • Exceeds CSA cold bend / cold impact (-40°C / -35°C)

Power and Control Cable Color Legend:

Conductor # Color
1 Black
2 Red
3 Blue
4 Orange

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question