General Cable Uniblend® PVC High Speed Type MV-105 750MCM Three Conductor 115 Mils EPR Copper Tape Shield with Overall PVC Jacket Medium Voltage Power Shielded 5 kV and 8 kV UL

General Cable Uniblend® PVC High Speed Type MV-105 750MCM Three Conductor 115 Mils EPR Copper Tape Shield with Overall PVC Jacket Medium Voltage Power Shielded 5 kV and 8 kV UL

Select gauge from drop-down menu for prices:

General Cable Uniblend® PVC High Speed Type MV-105 750MCM Three Conductor 115 Mils EPR Copper Tape Shield with Overall PVC Jacket Medium Voltage Power Shielded 5 kV and 8 kV UL

Product Details

Conductor: 6 AWG thru 1000 kcmil annealed bare copper compact Class B strand

Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation: Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers

Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer free stripping from insulation

Metallic Shield: 5 mil annealed copper tape with an overlap of 25% Grounding

Conductor: 1 bare grounding conductor may be in contact with metallic shielding tape

Overall Jacket: Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

Options:
• STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610
• 3 bare copper ground wires
• Covered ground wires

Applications:
• Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical
• In wet or dry locations when installed in accordance with NEC
• In aerial, direct burial, conduit, open tray and underground duct installations

Features:
• Rated at 105?C
• Low friction for easy pulling
• Excellent heat and moisture resistance
• Outstanding corona resistance
• Flexibility for easy handling
• High dielectric strength
• Low moisture absorption
• Electrical stability under stress
• Low dielectric loss
• Chemical-resistant
• Meets cold bend test at -35?C
• 105°C rating for continuous operation
• 140°C rating for emergency overload conditions
• 250°C rating for short circuit conditions

Compliances:
• National Electrical Code (NEC)
• UL 1072
• ICEA S-93-639/NEMA WC74
• ICEA S-97-682
• AEIC CS8
• UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501
• UL 1685 (70,000 BTU/hr)
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant

Optional Flame Tests: IEEE 1202 (70,000 BTU/hr)/CSA FT4

Packaging:
• Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit
• Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

technical specification:
cond. size (awg/kcmil) 750
nominal conductor diameter(inches) 0.91
insulation diameter inches(min.) 1.170
insulation diameter inches(max.) 1.250
ground wire(awg) 1/0
nominal jacket thickness(inches) 0.140
nominal jacket thickness(mm) 3.56
nominal cable(diameter in inches) 3.14
nominal cable(diameter in mm) 79.76
nominal cable(weight in lbs/1000ft) 9833
nominal cable(weight in kg/km) 14633
copper weight(lbs/1000ft) 7629
copper weight(kg/km) 11352
ampacity(conduit in air (1) in 90?c) 570
ampacity(conduit in air (1) in 105?c) 635
ampacity(underground duct (2) in 90?c) 545
ampacity(underground duct (2) in 105?c) 585
ampacity(tray (3) in 90?c) 670
ampacity(tray (3) in 105?c) 745
catalog number 15493.407005*