General Cable Uniblend® CPE High Speed Type MV-105 2 AWG 3C 115 Mils EPR Medium Voltage Power Shielded

General Cable Uniblend® CPE High Speed Type MV-105 2 AWG 3C 115 Mils EPR Medium Voltage Power Shielded

Product Details

Conductor: 6 AWG thru 1000 kcmil annealed bare copper compact Class B strand

Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation: Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers

Extruded Insulation Shield (EIS):Thermoset semi-conducting polymeric layer free stripping from insulation

Metallic Shield: 5 mil annealed copper tape with an overlap of 25%

Grounding Conductor: 1 bare grounding conductor may be in contact with metallic shielding tape

Overall Jacket: Flame-retardant, moisture- and sunlight-resistant Chlorinated Polyethylene (CPE)

Options: STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610

Applications:
• Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical
• In wet or dry locations when installed in accordance with NEC
• In aerial, direct burial, conduit, open tray and underground duct installations

Features:
• Rated at 105?C
• Excellent heat and moisture resistance
• Outstanding corona resistance
• Flexibility for easy handling
• Low friction for easy pulling
• High dielectric strength
• Low moisture absorption
• Electrical stability under stress
• Low dielectric loss
• Chemical-resistant
• Meets cold bend test at -35?C
• 105°C rating for continuous operation
• 140°C rating for emergency overload conditions
• 250°C rating for short circuit conditions

Compliances:
• National Electrical Code (NEC)
• UL 1072
• ICEA S-93-639/NEMA WC74
• ICEA S-97-682
• AEIC CS8
• UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501
• UL 1685 (70,000 BTU/hr)
• OSHA Acceptable
• RoHS Compliant

Optional Flame Tests: IEEE 1202 (70,000 BTU/hr)/CSA FT4

Packaging:
• Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit
• Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

technical specification:
cond size (awg/kcmil) 2
nominal conductor diameter(inches) 0.27
insulation diameter inches(min.) 0.510
insulation diameter inches(max.) 0.590
ground wire (awg)
6
nominal jacket thickness(inches) 0.080
nominal jacket thickness(mm) 2.03
nominal cable(diameter in inches) 1.51
nominal cable(diameter in mm) 38.35
nominal cable(weight in lbs/1000 ft) 1511
nominal cable(weight in mm) 2249
copper weight(lbs/1000 ft) 860
copper weight(mm) 1279
ampacity(conduit in air (1) in 90?c) 145
ampacity(conduit in air (1) in 105?c) 165
ampacity(underground duct (2) in 90?c) 150
ampacity(underground duct (2) in 105?c) 160
ampacity(tray (3) in 90?c) 165
ampacity(tray (3) in 105?c) 185
catalog number 15593.400205*

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.