General Cable GenFree Uniblend® High Speed Type MV-105 3C 115 Mils EPR Medium Voltage Power Shielded UL

General Cable GenFree Uniblend® High Speed Type MV-105 3C 115 Mils EPR Medium Voltage Power Shielded UL

Product Details

Conductor: 6 AWG thru 1000 kcmil annealed bare copper compact Class B strand

Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation: Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers

Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer free stripping from insulation

Metallic Shield: 5 mil annealed copper tape with an overlap of 25%

Grounding Conductor: 1 bare grounding conductor may be in contact with metallic shielding tape

Overall Jacket: Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Options: STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610

Applications:
• Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical
• In wet or dry locations when installed in accordance with NEC
• In aerial, direct burial, conduit, open tray and underground duct installations

Features:
• Rated at 105?C
• Excellent heat and moisture resistance
• Outstanding corona resistance
• Flexibility for easy handling
• Low friction for easy pulling
• High dielectric strength
• Low moisture absorption
• Electrical stability under stress
• Low dielectric loss
• Chemical-resistant
• Meets cold bend test at -35?C
• 105°C rating for continuous operation
• 140°C rating for emergency overload conditions
• 250°C rating for short circuit conditions

Compliances:
• National Electrical Code (NEC)
• UL 1072
• ICEA S-93-639/NEMA WC74
• ICEA S-97-682
• ICEA T-33-655
• AEIC CS8
• UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501
• UL 1685 (70,000 BTU/hr)
• OSHA Acceptable
• RoHS Compliant
Optional Flame Tests: IEEE 1202 (70,000 BTU/hr)/CSA FT4

Packaging:
• Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit
• Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

cond.
size
(AWG/
kcmil)
nominal
cond.
diameter
insulation
diameter
inches
ground
wire
(AWG)
nominal jacket
thickness
copper
weight
ampacity general
cable
part
number
conduit inair (1) undergrnd
duct
tray (3)
inches min. max. inches mm lbs/
1000ft
kg
/km
90?c 105?c 90?c 105?c 90?c 105?c
6 0.17 0.415 0.490 6 0.080 2.03 460 685 83 92 88 95 93 105 15693.400605*
4 0.22 0.455 0.535 6 0.080 2.03 616 917 105 120 115 125 120 135 15693.400405*
2 0.27 0.510 0.590 6 0.080 2.03 860 1279 145 165 150 160 165 185 15693.400205*
1/0 0.34 0.580 0.655 4 0.080 2.03 1290 1919 195 215 195 210 215 240 15693.405105*
2/0 0.38 0.620 0.695 4 0.080 2.03 1556 2315 220 245 220 235 245 275 15693.405205*
4/0 0.48 0.720 0.795 3 0.110 2.79 2344 3488 290 320 285 305 325 360 15693.405405*
250 0.53 0.770 0.850 2 0.110 2.79 2759 4105 315 350 310 335 360 400 15693.406005*
350 0.62 0.870 0.945 2 0.110 2.79 3713 5525 385 430 375 400 435 490 15693.406205*
500 0.74 0.990 1.065 1 0.110 2.79 5191 7724 470 525 450 485 535 600 15693.406505*
750 0.91 1.170 1.250 1/0 0.140 3.56 7629 11352 570 635 545 585 670 745 15693.407005*
1000 1.06 1.320 1.400 2/0 0.140 3.56 10070 14985 650 725 615 660 770 860 15693.407505*

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question