General Cable Uniblend® PVC High Speed 4/0 AWG Type MV-105 3C 345 Mils EPR Copper Tape Shield with Overall PVC Jacket Medium Voltage Power Shielded UL

General Cable Uniblend® PVC High Speed 4/0 AWG Type MV-105 3C 345 Mils EPR Copper Tape Shield with Overall PVC Jacket Medium Voltage Power Shielded UL

Uniblend PVC High Speed 4/0 AWG Type MV-105 3C 345 Mils EPR Copper Tape Shield with Overall PVC Jacket Medium Voltage Power Shielded UL

Conductor: 1/0 AWG thru 750 kcmil annealed bare copper compact Class B strand

Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stress control layer over conductor

Insulation: Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers

Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer free stripping from insulation

Metallic Shield: 5 mil annealed copper tape with an overlap of 25%

Grounding Conductor: 1 bare grounding conductor may be in contact with metallic shielding tape

Overall Jacket: Low-friction, lead-free, flame-retardant, moistureand sunlight-resistant Polyvinyl Chloride (PVC)

Options: STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-610

Applications:
• Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical
• Suitable for use in wet or dry locations when installed in accordance with NEC
• In aerial, direct burial, conduit, open tray and underground duct installations

Features:
• Rated at 105?C
• Low friction for easy pulling
• Excellent heat and moisture resistance
• Outstanding corona resistance
• Flexibility for easy handling
• High dielectric strength
• Low moisture absorption
• Electrical stability under stress
• Low dielectric loss
• Chemical-resistant
• Meets cold bend test at -35?C
• 105°C rating for continuous operation
• 140°C rating for emergency overload conditions
• 250°C rating for short circuit conditions

Compliances:
• National Electrical Code (NEC)
• UL 1072
• ICEA S-93-639/NEMA WC74
• ICEA S-97-682
• AEIC CS8
• UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501
• UL 1685 (70,000 BTU/hr)
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant
Optional Flame Tests: IEEE 1202 (70,000 BTU/hr)/CSA FT4

Packaging:
• Material cut to length and shipped on nonreturnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit
• Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing

technical specification
cond. size(AWG/kcmil) 4/0
nominal conductor diameter(inches) 0.48
insulation diameter inches(min.) 1.160
insulation diameter inches(max.) 1.260
ground wire(AWG) 3
nominal jacket thickness(inches) 0.140
nominal jacket thickness(mm) 3.56
nominal cable(diameter in inches) 3.10
nominal cable(diameter in mm) 78.74
nominal cable(weight in lbs/1000 ft) 5313
nominal cable(weight in kg/km) 7906
copper weight(lbs/1000 ft) 2465
copper weight(kg/km) 3668
ampacity(conduit in air (1) in 90?c) 290
ampacity(conduit in air (1) in 105?c) 320
ampacity(underground duct (2) in 90?c) 285
ampacity(underground duct (2) in 105?c) 305
ampacity(tray (3) in 90?c) 325
ampacity(tray (3) in 105?c) 360
catalog number 15493.485405*