General Cable DuraSheath® High Speed Type MV-90 6 Gauge EPR XL-CPE Medium Voltage Power Nonshielded 2400 V UL

General Cable DuraSheath® High Speed Type MV-90 6 Gauge EPR XL-CPE Medium Voltage Power Nonshielded 2400 V UL

Select gauge from drop-down menu for prices:

General Cable DuraSheath® High Speed Type MV-90 6 Gauge EPR XL-CPE Medium Voltage Power Nonshielded 2400 V UL
DURASHEATH HIGH SPEED TYPE MV-90 6 GAUGE EPR XL-CPE MEDIUM VOLTAGE POWER NONSHIELDED 2400 V UL

Conductor: 8 AWG thru 1000 kcmil annealed bare copper compact Class B strand

Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stresscontrol layer over conductor

Insulation: Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black jacket material

Jacket: Lead-Free Cross-linked Chlorinated Polyethylene (XL-CPE)

Applications:
• Proven record of reliable performance through extensive use in these applications: pulp and paper mills, petrochemical plants, sewage treatment facilities, water treatment plants, steel mills, textile mills, utility power generating stations, scrubbers and other environmental protection systems, railroad and mining facilities
• For use in industrial and utility applications where ease of installation is a major concern because of limited space and exposure to personnel is minimal
• For use in wet or dry locations when installed in accordance with NEC
• For use in aerial, conduit, open tray and underground duct installations

Features:
• Rated at 90?C
• Excellent heat and moisture resistance
• Flexibility for easy handling
• High dielectric strength
• Low moisture absorption
• Electrical stability under stress
• Low dielectric loss
• Chemical- and sunlight-resistant
• Simplification of splicing and terminating by elimination of need to handle cable shield
• Extra-tough, mechanically rugged composite insulation and jacket construction
• Low friction for easy pulling
• Meets cold bend test at -35?C
• 90°C rating for continuous operation
• 130°C rating for emergency overload conditions
• 250°C rating for short circuit conditions

Compliances:
• National Electric Code (NEC)
• ICEA S-96-659/NEMA WC71
• UL 1072
• UL listed as Type MV-90 for use in accordance with NEC, UL File # E90501
• Sizes 1/0 AWG and larger are listed and marked “FOR CT USE” in accordance with NEC and also meet IEEE 383 (70,000 BTU/hr)
• Listed “oil-resistant I”
• Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA acceptable

Packaging: Material cut to length and shipped on non-returnable wood reels

technical specification:
cond. size(awg/kcmil) 6
nominal conductor diameter(inches) 0.17
nominal conductor diameter(mm) 4.32
nominal extruded strand shield diameter(inches) 0.19
nominal extruded strand shield diameter(mm) 4.83
nominal insulation thickness(inches) 0.125
nominal insulation thickness(mm) 3.18
nominal insulation diameter(inches) 0.44
nominal insulation diameter(mm) 11.18
nominal cable o.d.(inches) 0.62
nominal cable o.d.(mm) 15.75
copper weight(lbs/1000ft) 81
copper weight(kg/km) 121
net weight(lbs/1000ft) 241
net weight(kg/km) 359
catalog number 14901.410605