General Cable Uniblend® CPE High Speed Type MV-105 220 Mils EPR Copper Tape Shield CPE Medium Voltage Power Shielded UL

General Cable Uniblend® CPE High Speed Type MV-105 220 Mils EPR Copper Tape Shield CPE Medium Voltage Power Shielded UL

Select gauge from drop-down menu for prices:

General Cable Uniblend® CPE High Speed Type MV-105 220 Mils EPR Copper Tape Shield CPE Medium Voltage Power Shielded UL

Product Details

Conductor: 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand 

Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stresscontrol layer over conductor 

Insulation: Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers 

Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer free stripping from insulation 

Metallic Shield: 5 mil annealed copper tape with an overlap of 25% 

Jacket: Flame-retardant, moisture- and sunlight-resistant Chlorinated Polyethylene (CPE)  

Options: STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610 

Applications: 
• Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines,   utility power generating stations, steel mills, textile plants and other industrial three-phase applications 
• For use in wet or dry locations when installed in accordance with NEC 
• For use in aerial, conduit, open tray and underground duct installations 
• For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5) 

Features: 
• Rated at 105?C 
• Excellent heat and moisture resistance 
• Excellent flame resistance 
• Outstanding corona resistance 
• Flexibility for easy handling 
• Low friction for easy pulling 
• High dielectric strength 
• Low moisture absorption 
• Electrical stability under stress 
• Low dielectric loss 
• Chemical-resistant 
• Meets cold bend test at -35?C 
• 105°C rating for continuous operation 
• 140°C rating for emergency overload conditions 
• 250°C rating for short circuit conditions 

Compliances: 
• National Electrical Code (NEC) 
• UL 1072 
• ICEA S-93-639/NEMA WC74 
• ICEA S-97-682 
• AEIC CS8 
• UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501 
• UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test 
• Sizes 1/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC 
• IEEE 1202 (70,000 BTU/hr)/CSA FT4 
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method 
• OSHA Acceptable 
• RoHS Compliant 

Packaging: 
• Material cut to length and shipped on nonreturnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit
• Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing

cond. size (awg/ kcmil) nominal cond. diameter conduit sizing (4) (inches) general cable part number Action
2 0.27 3 17131.130205 Request a Quote
1 0.31 3.5 17131.130105 Request a Quote
1/0 0.34 3.5 17131.135105 Request a Quote
2/0 0.38 3.5 17131.135205 Request a Quote
3/0 0.43 3.5 17131.135305* Request a Quote
4/0 0.48 4 17131.135405 Request a Quote
250 0.53 4 17131.136005 Request a Quote
350 0.62 5 17131.136205 Request a Quote
500 0.74 5 17131.136505 Request a Quote
750 0.91 6 17131.137005 Request a Quote
1000 1.06 6 17131.637505 Request a Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question